Example: air traffic controller

5619, Guardian Dual Check 1/4 Turn Non-Freeze Hydrant with ...

5-17-11 Added Note TBW CLF 6-13-11 Revised Note TBW CLDATEDESCRIPTIONBYCKD. BYWEIGHTPOUNDSVOLUMECUBIC FEETFIGURE NUMBERLOCATIONFIGURENUMBERDIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICEWE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATADRAWN BY:CHECKED BY:APPROVED BY:DATE:SCALE:SIZEADRAWING NUMBER56195619 RNCLHCEL3-24-03 NONEs5619 OPTIONAL MATERIALS:Polished Bronze Face -PBChrome Plated Face -CP5(125)1 1/2" (38) 1/8(3)TOP VIEWFRONT VIEW1/2 (13) FemaleNPT Inlet3/4 (19) MaleNPT InletAdjustableWall Clamp(Specify -WC)(Note 4)FIG. 56192 9/16 (64)EXPOSED HOSE CONNECTIONFUNCTION: For installation in interior or exterior building walls where an exposed hose connection is positive Non-Freeze protection.

13 Actuator Cartridge Assembly 13a **Retaining Ring 13b **Valve Body 13c **Actuator O-Ring (2) * * * * * * * 4 2 5 9 7 8 11 10 6 11 ** 13* 13 13a 13b 13c 13d 13e 13f 13g 13h 13j 13k 13m Actuator Cartridge Assembly These Parts Accessible from Face of Hydrant by Removing Wall Plate Assembly. These Replacement Parts Available in HPRK-19 * Parts ...

Tags:

  Turn, Actuator

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 5619, Guardian Dual Check 1/4 Turn Non-Freeze Hydrant with ...

1 5-17-11 Added Note TBW CLF 6-13-11 Revised Note TBW CLDATEDESCRIPTIONBYCKD. BYWEIGHTPOUNDSVOLUMECUBIC FEETFIGURE NUMBERLOCATIONFIGURENUMBERDIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICEWE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATADRAWN BY:CHECKED BY:APPROVED BY:DATE:SCALE:SIZEADRAWING NUMBER56195619 RNCLHCEL3-24-03 NONEs5619 OPTIONAL MATERIALS:Polished Bronze Face -PBChrome Plated Face -CP5(125)1 1/2" (38) 1/8(3)TOP VIEWFRONT VIEW1/2 (13) FemaleNPT Inlet3/4 (19) MaleNPT InletAdjustableWall Clamp(Specify -WC)(Note 4)FIG. 56192 9/16 (64)EXPOSED HOSE CONNECTIONFUNCTION: For installation in interior or exterior building walls where an exposed hose connection is positive Non-Freeze protection.

2 Adaptable to all types of wall FURNISHED: Guardian DUAL CHECK1/4 turn Non-Freeze WALL Hydrant WITH AUTOMATIC DRAININGINTEGRAL VACUUM BREAKER AND DUAL Check VALVE 1/4 turn of the Key Allows Full Flow to Be Obtained3/4 HoseConnectionIntegral Vacuum Breakerand Dual Check Valve"T" Handle KeyBronze Quarter turn Non-FreezeAutomatic Draining Hydrant with Stainless Steel Face, Hose Connection, Integral Vacuum Breaker and Dual Check Valve and "T" Handle ANSI SpecificationsComplies w/ ASSE 1019-B,1052 and Listed- File #2749 Patent No. US 6,752,167 5. Add 3/4 (19) to Overall Length When SpecifiedNOTES:1.

3 Recommended wall opening 2 1/4 (57) x 4 (100). 2. When ordering, specify wall thickness in 1 (25) increments as follows 4,5,6,7, When wall clamp -WC is desired, increase wall thickness dimension by 2 (51). 3. All Jay R. Smith hydrants are manufactured with "NO-LEAD" brazing rings, and USDA approved lubricants. 6. When specifying Fig. 5619 (-SAP) the wall thickness shall be 2 (51).7. Dimensions shown in parentheses are in The AB1953, California Lead Law, and NSF/ANSI Standard 61-2008 - Drinking Water System Components are not applicable to Jay R.

4 Smith hydrants as they do not convey/dispense water for human consumption through drinking or FOR IRRIGATION PURPOSES :Adjustable Wall Clamp -WC (Note 4)1 (25) Hose Connection -HC11 (25) Male NPT Inlet Connection -IC1 (Note 5)Mild Climate -SAP (Note 6)Wheel Handle (-WH)Wall Thickness(Note 2)G 2-4-13 Revised Notes TBW CLH 4-5-18 Added Notes TBW BWWARNING: Cancer and Reproductive Harm - CO. MEMBER OF MORRIS GROUP INTERNATIONALPOST OFFICE BOX 3237 MONTGOMERY, ALABAMA 36109-0237 (USA)TEL: 334-277-8520 FAX: 334-272-7396 MEMBER OF:ASPE SANITARYENGINEERINGP revention Rather Than CureSINCE 1926 PLUMBING AND DRAINAGE INSTITUTE MEMBER MEMBERI nstaller is responsible for providing a 100% watertight positive seal at the Hydrant to wall interface.

5 Seal all the flange with an appropriate sealant recommended by a sealant manufacturer. NOTE: Jay R. Smith does not warrant the perfor-mance or life expectancy of the sealant of a small amount of water may occur from the Vacuum Breaker upon the initial opening and closing of this Hydrant . This is normal BYWEIGHTPOUNDSVOLUMECUBIC FEETFIGURE NUMBERLOCATIONFIGURENUMBERDIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICEWE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATADRAWN BY:CHECKED BY:APPROVED BY:DATE:SCALE:SIZEADRAWING NUMBER5619BS5619 BSRNCLACEL3-24-03 NONES5619 BSGUARDIAN DUAL Check Hydrant PARTS LISTHYDRANT PARTS Casing Assembly2 Wall Plate Assembly3 Key4 Wall Plate Securing Screw (5) 5 Wall Plate Gasket1a Head1b Casing1c Valve Housing6 Stationary Operator Piece10 Operator Rod11 Operator Rod Guides (2)12 Vacuum Breaker/Dual Check Valve Assembly 7 Moveable Operator Piece8 Moveable Operator O-Ring 9 Drain Hole Seal (2)12a **Vacuum Breaker Housing12e **Flow Diverter12f **Large O-Ring12b **Spring (2)12c **Cone Washer (2)

6 12d **Small O-Ring13e **Valve Actuator13f **Nylon Thrust Washer13g **Rotating Ceramic Disc 13d **Nylon Thrust Spacer13j **O-Ring 13k **O-Ring Gasket Retainer13m **Rubber Seal 13h **Fixed Ceramic Disc13 actuator Cartridge Assembly13a **Retaining Ring13b **Valve Body13c ** actuator O-Ring (2)**4259781110116**131313a13b13c13d13e1 3f13g13h13j13k13mActuator Cartridge AssemblyThese Parts Accessible from Face of Hydrant by Removing Wall Plate Assembly. These Replacement Parts Available in HPRK-19*Parts supplied as an assembly only, see part 12 or 13.**These Replacement Parts Available in HPRK-19VB**42*12a*12b*12c12 Vacuum Breaker/Dual Check Valve Assembly*12d*12e*12f*12b*12c*51331a511c1 b12101172968 JAY CO.

7 MEMBER OF MORRIS GROUP INTERNATIONALPOST OFFICE BOX 3237 MONTGOMERY, ALABAMA 36109-0237 (USA)TEL: 334-277-8520 FAX: 334-272-7396 MEMBER OF:ASPE SANITARYENGINEERINGP revention Rather Than CureSINCE 1926 PLUMBING AND DRAINAGE INSTITUTE MEMBER MEMBERWARNING: Cancer and Reproductive Harm - 4-5-18 Added Note TBW BW Installer is responsible for providing a 100% watertight positive seal at the Hydrant to wall interface. Seal all the flange with an appropriate sealant recommended by a sealant manufacturer. NOTE: Jay R. Smith does not warrant the performance or life expectancy of the sealant material.