Example: marketing

5L EVF Series Paint Spray (Suffix S718) Fluorescent ...

5L EVF Series Cl. I, Div. 1, Groups C, D. Cl. I, Zone 1, Group IIB. Paint Spray ( suffix S718). Wet Locations ( suffix S718). Fluorescent Luminaires Cl. II, Div. 1, Groups E, F, G 3, 3R, IP54 ( suffix S718). Cl. III, Simultaneous Presence Applications: EVF Luminaires are used in areas where hazardous fumes, gases, or dusts are present EVF Luminaires with S718 option are designed specifically for use inside Paint Spray booths where hazardous fumes, gases, and Paint residue are present;. this includes powder Paint process areas EVF Luminaires with S718 option are 3-lamp 2-lamp with angle reflector also suitable for use in wet locations Ordering Information: Features: Furnished For Hub Line Volts 1-Lamp 2-Lamp 3-Lamp 4-Lamp All EVF Luminaires: Use with Size 60 Hz Cat. # Cat. # Cat. # Cat. #. Provide cool, even light with natural color 32 watt, T-8 medium 3/4" 120 277 EVF21029/UNV EVF22029/UNV EVF23029/UNV EVF24029/UNV.

5L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1115 EVF Series Photometric Data …

Tags:

  Fluorescent, Suffix, Spray, Paint, 781ss, Paint spray, Suffix s718

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 5L EVF Series Paint Spray (Suffix S718) Fluorescent ...

1 5L EVF Series Cl. I, Div. 1, Groups C, D. Cl. I, Zone 1, Group IIB. Paint Spray ( suffix S718). Wet Locations ( suffix S718). Fluorescent Luminaires Cl. II, Div. 1, Groups E, F, G 3, 3R, IP54 ( suffix S718). Cl. III, Simultaneous Presence Applications: EVF Luminaires are used in areas where hazardous fumes, gases, or dusts are present EVF Luminaires with S718 option are designed specifically for use inside Paint Spray booths where hazardous fumes, gases, and Paint residue are present;. this includes powder Paint process areas EVF Luminaires with S718 option are 3-lamp 2-lamp with angle reflector also suitable for use in wet locations Ordering Information: Features: Furnished For Hub Line Volts 1-Lamp 2-Lamp 3-Lamp 4-Lamp All EVF Luminaires: Use with Size 60 Hz Cat. # Cat. # Cat. # Cat. #. Provide cool, even light with natural color 32 watt, T-8 medium 3/4" 120 277 EVF21029/UNV EVF22029/UNV EVF23029/UNV EVF24029/UNV.

2 Rendition Bi-pin 265MA lamps 3/4" 347 EVF21029/347 EVF22029/347 EVF23029/347 EVF24029/347. Reduce relamping schedule (long lamp life) 40 watt, T-12 medium 3/4" 110 125 EVF21082 EVF22082 EVF23082 EVF24082. Continuous and uniform illumination Bi-pin rapid start 3. /4" 277 EVF21087 EVF22087 EVF23087 EVF24087. made possible by mounting end to end 430MA lamps 3. /4" 347 EVF21089/347 EVF22089/347 EVF23089/347 EVF24089/347. (no space needed between luminaires for relamping) 40 watt, T-12 single /4". 3. 110 125 EVF21032 EVF22032 EVF23032 EVF24032. No special tools required for relamping; pin, slimline /4". 3. 277 EVF21037 EVF22037 EVF23037 EVF24037. threaded lamp tube cover provides quick 425MA lamps /4". 3. 347 EVF21039/347 EVF22039/347 EVF23039/347 EVF24039/347. and easy access for relamping 60 watt, T-12 /4". 3. 110 125 EVF21062 EVF22062 EVF23062 EVF24062.

3 Threaded joints on lamp tube and wiring recessed contact, /4". 3. 277 EVF21067 EVF22067 EVF23067 EVF24067. chamber covers permit easy access for 800MA lamps /4". 3. 347 EVF21069/347 EVF22069/347 EVF23069/347 EVF24069/347. lower maintenance costs Reflectors can be removed or replaced 110 watt, T-12 /4". 3. 110 125 EVF21072 EVF22072 EVF23072 EVF24072. with only a screwdriver recessed contact, /4". 3. 277 EVF21077 EVF22077 EVF23077 EVF24077. Easy to install; factory-sealed and wired 1500MA lamps /4". 3. 347 EVF21079/347 EVF22079/347 EVF23079/347 EVF24079/347. luminaire facilitates installation Standard electronic ballast for 32 watt 50 Hz not available. and 40 watt rapid start luminaires Standard energy-efficient ballast for 40 Certifications and Options: Mounting watt slimline, 60 watt and 110 watt Compliances: Description suffix Accessories: luminaires For suitability for wet NEC and CEC: Various hazardous area Low temperature ballast is supplied as locations and locations Class I, Division 1, Groups C, D fittings are used to mount 5L.

4 Standard on 32 watt T8 (0 F), 40 watt having deposits of Class I, Zone 1, Group IIB EVF Luminaires. The fittings slimline (0 F), 60 watt and 110 watt readily combustible Class II, Groups E, F, G shown on next page support luminaires (-20 F) Paint residue .. S718 the unwired (relamping) end. All exposed hardware is stainless steel Class III Corro-free epoxy For the wired (ballast) end Simultaneous Presence (Cl. I powder S752. for maximum protection against any of the luminaire hangers and Cl. II) With 45 angle reflectors corrosion, and for longer luminaire life for hazardous locations Paint Spray (S718) in lieu of straight down Copper-free aluminum construction reflectors .. (listed in Section 7L) can be UL Standards: S369. throughout means lighter luminaire Fused (not suitable for used. CPS conduit outlet weight, easier installation, and excellent 844 Hazardous (Classified) bodies with hub covers Locations marine applications).

5 S658. corrosion resistance Furnished with S714 (listed in Section 3F) are also 1598 Luminaires Low temperature suitable. All exterior materials are non-sparking CSA Standards: electromagnetic ballast Type P ballasts furnished in compliance No. 137. with NEC for 40 watt T12 rapid Size Ranges: start luminaires rated Heavy-duty glass lamp tubes provide Standard Materials: for 0 F .. BY. 1, 2, 3, and 4-lamp maximum strength and impact resistance Copper-free aluminum except to protect lamps sheet aluminum reflectors Electrical Rating EVF Luminaires with S718 Option: All joints sealed Standard Finishes: Ranges: Natural except reflectors 32 to 110 watts Inside Paint booth mounting capabilities provide greater flexibility in luminaire Reflectors white epoxy placement, avoids necessity of powder coat Temperature Performance Data: complicated design and installation work, (Based on 40 C Ambient).

6 And improves task lighting control Class I/Class II/Zone 1. Smooth, simple design makes it easy to Lamp Type 1-Lamp 2-Lamp 3-Lamp 4-Lamp Supply Wire remove any accumulated deposits of Paint residue 32/40W T5 T5 T5 T5 75 C. 60W T5 T5 T5 T5 75 C. 110W T4 T4 T4 T4 90 C. 1112 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton's Crouse-Hinds Business EVF Series Accessories Relamping Information 5L. Fluorescent Luminaires Ceiling Saddle Relamping Information Conduit Support Size Description (In.) Cat. #. Ceiling Saddle for 3. /4 EVF20. Conduit Support Ceiling Saddle Support Hook Adjacent ends of two fixtures suspended in line close together One cover removed and Description Cat. # lamp partly withdrawn Ceiling Saddle for EVF021. Support Hook Where fixtures abut, space for relamping is obtained by lowering one end of the tube assembly as shown.

7 Without tools, the lamp Support Hook receptacle and mounting plate assemblies can be removed and for Conduit the lamp withdrawn. In inserting, the reverse procedure is followed. Size Description (In.) Cat. #. Support Hook /4. 3. EVF21. for Conduit End of one fixture lowered for relamping Dimensions: 5L. End view Fixture Type No. Lamps a b c d e f No. of Lamps Width 32 watt, T-8 Bi-pin 1-Lamp 61/8. 40 watt, T-12 Bi-pin 2-Lamp 111/2. 40 watt, T-12 Single pin slimline 1 or 2 44 11 533/8 55 95 101/4 3-Lamp 18. 60 watt, T-12 Recessed contact 3 or 4 461/2 81/2 533/8 55 100 101/4 4-Lamp 241/2. 110 watt, T-12 Recessed contact US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton's Crouse-Hinds Business 1113. 5L EVF Series Photometric Data Fluorescent Luminaires Luminaire: All 1-Lamp EVF Luminaires Luminaire: All 2-Lamp EVF Luminaires Lamp: 1-40/T-12, 1-60/T-12 Lamp: 2-40/T-12, 2-38/T-12, 2-60/T-12, 2-110/T12.

8 Zonal Degrees: 0 30 0 40 0 60 0 90 Zonal Degrees: 0 30 0 40 0 60 0 90. Zonal Lumens: 580 953 1633 1897 Zonal Lumens: 1055 1765 3262 4125. Total Bare Lamp Lumens: 3100 Total Bare Lamp Lumens: 6300. All data provided is for 40W rapid All data provided is for 40W rapid start cool white lamps. Use start cool white lamps. Use following candlepower/lumen following candlepower/lumen multipliers for other lamp sizes: multipliers for other lamp 32W sizes: 32W 40W Slimline 40W Slimline 60W Cool white 60W Cool white 110W Cool white 110W Cool white Example: Zonal lumens of 1 40W Example: Zonal lumens of 2 40W. lamp for 0 60 is 1633. Zonal lamp for 0 60 is 3262. Zonal lumens of 1 60W lamp for 0 60 is lumens of 2 60W lamps for 0 60. 1633 x = 2107 is 3262 x = 4208. Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% Effective Floor Cavity Reflectance 20%.

9 % Reflectance Room Cavity Ratio % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 4 5 Eff. Ceil. Wall 1 2 3 4 5. 50 .697 .616 .546 .485 .434 50 .697 .616 .546 .485 .434. 80 30 .670 .574 .497 .430 .376 80 30 .670 .574 .497 .430 .376. 10 .647 .539 .458 .388 .334 10 .647 .539 .458 .388 .334. 50 .682 .604 .538 .477 .425 50 .682 .604 .538 .477 .425. 70 30 .658 .565 .490 .426 .372 70 30 .658 .565 .490 .426 .372. 10 .635 .534 .454 .385 .331 10 .635 .534 .454 .385 .331. 50 .653 .580 .518 .460 .412 50 .653 .580 .518 .460 .412. 50 30 .633 .549 .478 .416 .365 50 30 .633 .549 .478 .416 .365. 10 .616 .520 .446 .380 .329 10 .616 .520 .446 .380 .329. 50 .627 .559 .500 .445 .399 50 .627 .559 .500 .445 .399. 30 30 .612 .533 .467 .407 .357 30 30 .612 .533 .467 .407 .357. 10 .597 .509 .438 .375 .325 10 .597 .509 .438 .375 .325. 50.

10 605 .539 .484 .431 .388 50 .605 .539 .484 .431 .388. 10 30 .591 .517 .455 .397 .351 10 30 .591 .517 .455 .397 .351. 5L. 10 .579 .498 .431 .370 .321 10 .579 .498 .431 .370 .321. % Reflectance Room Cavity Ratio % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 9 10 Eff. Ceil. Wall 6 7 8 9 10. 50 .391 .351 .316 .289 .252 50 .391 .351 .316 .289 .252. 80 30 .334 .295 .262 .235 .198 80 30 .334 .295 .262 .235 .198. 10 .294 .257 .223 .197 .164 10 .294 .257 .223 .197 .164. 50 .384 .346 .312 .285 .248 50 .384 .346 .312 .285 .248. 70 30 .330 .292 .260 .233 .198 70 30 .330 .292 .260 .233 .198. 10 .290 .255 .222 .197 .164 10 .290 .255 .222 .197 .164. 50 .372 .336 .303 .277 .242 50 .372 .336 .303 .277 .242. 50 30 .324 .286 .255 .229 .195 50 30 .324 .286 .255 .229 .195. 10 .288 .252 .221 .196 .162 10 .288 .252 .221 .196 .162. 50.


Related search queries