Transcription of 60 Hz - Cat Used Power
1 RENTALXQ500 SOUND ATTENUATEDPOWER MODULE60 HzFEATURESEMISSIONS EPA and CARB Emissions Certified fornon-road mobile 3456 ATAAC diesel engine Reliable, rugged, durable design Field-proven in thousands of applicationsworldwide Four-stroke-cycle diesel engine combinesconsistent performance and excellent fueleconomy with minimum weightCAT SR4B GENERATOR 12 lead 480/277 volt generator reconnectableto 240/139 volt Optimum winding pitch for minimum totalharmonic distortion and maximum efficiency Segregated low voltage (AC/DC) accessorybox provides single point access to accessoryconnectionsENCLOSURE Rugged 20 ISO container Sound attenuated to 70 db(A) Optional undercarriage with ladders LockableCAT CONTROL PANEL Caterpillar EMCPII+ panel Multi-unit semi-automatic paralleling capabilityENVIRONMENTALLY FRIENDLY design Sound attenuated for low noise operation UL listed, double-wall fuel tank Spill containment for coolant, oil and fuelMULTI-VOLTAGE DISTRIBUTION PANEL Load door safety switch, engine faults, andshut down system Rust-free hinges on side opening door Adequate space for line and plug connectionwithout interference Remote start and stop contactsSINGLE-SOURCE SUPPLIER Complete systems designed at CaterpillarISO9001 certified facilities Certified Prototype Testedwith torsionalanalysisWORLDWIDE PRODUCT SUPPORT Worldwide parts availability through theCaterpillar dealer network With over 1,200 dealer outlets operating in166 countries.
2 You re never far from theCaterpillar part you need of parts orders filled within 48 best product support record in the industry Caterpillar dealer service technicians aretrained to service every aspect of your electricpower generation systemWHERE THE WORLD TURNS FOR POWERLEHE2798-02 Shown withOptional EquipmentRENTAL2 LEHE2798-02 CAT ENGINE3456 ATAAC, 4-stroke-cycle watercooled dieselBore mm (in)..140 ( )Stroke mm (in)..171 ( )Displacement L (cu in).. (966)Compression AftercooledFuel Unit InjectionGovernor (ADEM II)CAT SR4B GENERATORF rame of of of 1446 Recognized Class H InsulationIP proof shaftOverspeed than 5% deviationParalleling kit droop sensing with adjustable1:1 or 2:1 Volts/Hz, UL 508A ListedTIF ..Less than 50 THD ..Less than 5%CAT CONTROL PANEL24 Volt DC ControlNEMA 1, IP22 enclosureLockable hinged doorGenerator instruments meet ANSI C-39-1 Enclosure mountedSingle location customer connector pointSynchronizing lights for multi-unit semi-automatic parallelingSPECIFICATIONSFACTORY INSTALLED STANDARD& OPTIONAL EQUIPMENTSTANDARD FEATURESAir Inlet SystemDual element air cleaner with service indicatorCircuit Breaker1600 amp main circuit breaker with 24 V shunt tripSemi-automatic paralleling protectionControl PanelGenerator controls and monitoringFuel tank monitoringEngine controls and monitoringDigital displaySynchronizing lightsCooling SystemBase mounted radiator sized for 43 C (110 F)
3 Ambient External coolant drain service connection Fan and belt guardsLow coolant level alarm or shutdownCaterpillar Extended Life CoolantDistribution PanelLockable doorsSafety switch with circuit breaker trip protectionIndividual bus bar connections120V and 240V convenience receptacles with individual circuit breakers480/240 quick changeover boardRemote start/stop contactsShore Power input for battery charger, generator space heater and JW heaterEnclosureSound attenuated to 70 db(A) at 7 m (23 ft.)Air intake louversVertical radiator and exhaust discharge plenum24 V DC lighting system with shut-off timerLockable doorsEngine fluid spill containmentFuel SystemUL listed dual wall fuel tankExternal fuel drain service connectionPrimary fuel filter with water separatorFuel priming pumpFuel pressure gaugeGenerator12 lead 480/277 volt generator reconnectable to 240/139UL and CSA approvedAnti-condensation space heaterPM excitedCostal insulationVR3 voltage regulatorMounting SystemAnti-vibration engine and generator mountsStarting/ChargingBattery set with disconnect switch5 amp battery charger 24 volt starting motorHeavy duty 45 amp charging alternatorUL approved jacket water heater with thermostat and shut-off valvesOPTIONAL FEATUREST railer/ 20 twin axle undercarriage UndercarriageUS DOT and Canadian highway code compliantRENTAL3 TECHNICAL DATAS tandbyPrimePower Rating 1800 rpm/ 60 hz /480
4 VoltsDM6217-01DM6218-01 Package PerformancePower ratingekW500455 Power rating @ pfkVA625569 Fuel Consumption100% load with fanl/hr (gal/hr) ( ) ( )75% load with fanl/hr (gal/hr) ( ) ( )50% load with fanl/hr (gal/hr) ( ) ( )Shipping Weight (Dry)Unit with trailerkg (lb)12,324 (27,170)Unit without trailerkg (lb)9,512 (20,970)Maximum Fuel Capacity WeightUnit with trailerkg (lb)14,365 (31,670)Unit without trailerkg (lb)11,553 (25,470) engine Lube Oil Capacityl (qts.)38 (40) engine Cooling System Capacityl (qts.) ( )Fuel Tank Capacity Grossl (gal)2445 (646)Fuel Tank Capacity Usablel (gal)2271 (600)Running Time @ 75% Primehours24 Sound Level @ 7 m (23 ft.)Standby *NOXg/hp-hr< < < < < < < < *Emissions data measurements are consistent with those described in EPA CFR 40 Part 89 Subpart D & E and ISO8178-1 formeasuring HC, CO, PM, NOX. engine exhaust emissions are in compliance with the EPA and California non-road regulationsreferenced in the above or Exceeds International Specifications: ABGSM TM3, AS1359, AS2789, BS4999, BS5000, BS5514,DIN6271, DIN6280, EGSA101P, IEC34/1, ISO3046/1, ISO8528,JEM1359, NEMA MG1-22, VDE0530, 89/392/EEC, 89/336/EECS tandby Output available with varying load for theduration of the interruption of the normal source Power in accordance with ISO8528.
5 Fuel stop powerin accordance with ISO3046/1, AS2789, DIN6271, and Output available with varying load for an unlimitedtime. Prime Power in accordance with ISO8528. 10% overloadpower in accordance with ISO3046/1, AS2789, DIN6271, andBS5514 available on based on SAE J1349 standard ratings also apply at ISO3046/1, DIN6271, and BS5514standard ratesare based on fuel oil of 35 API [@16 C (60 F)]gravity having an LHV of 42 780 kJ/kg (18,390 Btu/lb) when usedat 29 C (85 F) and weighing g/liter ( gal.).Additional ratings may be available for specific customerRequirements. Consult your Caterpillar representative for DEFINITIONS AND sourced 2003 CaterpillarAll rights Reference No.: DM6217-01, DM6218-01 Printed in (7-03)Materials and specifications are subject to change without International System of Units (SI) is used in this PANELP ackage DimensionsContainerWith TrailerLength6096 mm240 in7213 mm284 inWidth2438 mm96 in2438 mm96 inHeight2591 mm102 in4115 mm162 inCONTAINER DIMENSIONS FRONT VIEW2438 [96]2591[102]CONTAINER DIMENSIONS STREETSIDE VIEW1.
6 Load connection bus board2. Ground stud 1 2" NC, 4" L3. 50 amp 240V branch breaker4. 20 amp 240V branch breaker5. 20 amp 120V branch breaker6. 15 amp 120V branch breaker7. 50 amp 240V twistlock receptacle8. 20 amp 240V twistlock receptacle9. 20 amp 120V twistlock receptacle10. 20 amp 120V ground fault interrupter11. 15 amp 120V ground fault interrupterduplex receptacle12. 30 amp 120V battery charger/ generatorspace heater receptacle13. 30 amp 120V JWH receptacle14. Remote start/stop contacts15. Paralleling interface connections 1347891011131214566096 [240]2591[102]152