Example: barber

60100H-GRD TIMER-CONTROLLED GREASE …

205 GREASE INTERCEPTORSGREASE INTERCEPTORSINTERCEPTORSG rease Interceptor FeaturesA GREASE interceptor is a plumbing device installed in the sanitary drainage system to intercept fats, oils and GREASE (FOG) from the waste waterdischarge. It works by slowing the flow of water into the interceptor, which allows the FOG time to separate from the waste water. The FOG iscontained in the body of the interceptor allowing the FOG-free water to pass downstream by exiting the interceptor via a trap leg. Hydro-mechanicalgrease interceptors range in size from small 7 GPM units to large 500 GPM units. Units with installed GREASE removal devices are maximum GREASE efficiency JOSAM provides an external flow control with every interceptor which must be used as TIMER-CONTROLLED GREASE REMOVAL PUMPTIMER/CONTROLLERWall-mounted Programmable Timeractivates evacuation pump at pre-determined time (1-99 Days).

205 GREASE INTERCEPTORS INTERCEPTORS Grease Interceptor Features A grease interceptor is a plumbing device installed in the sanitary drainage system to intercept fats, oils and grease (FOG) from the waste water

Tags:

  Grease

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 60100H-GRD TIMER-CONTROLLED GREASE …

1 205 GREASE INTERCEPTORSGREASE INTERCEPTORSINTERCEPTORSG rease Interceptor FeaturesA GREASE interceptor is a plumbing device installed in the sanitary drainage system to intercept fats, oils and GREASE (FOG) from the waste waterdischarge. It works by slowing the flow of water into the interceptor, which allows the FOG time to separate from the waste water. The FOG iscontained in the body of the interceptor allowing the FOG-free water to pass downstream by exiting the interceptor via a trap leg. Hydro-mechanicalgrease interceptors range in size from small 7 GPM units to large 500 GPM units. Units with installed GREASE removal devices are maximum GREASE efficiency JOSAM provides an external flow control with every interceptor which must be used as TIMER-CONTROLLED GREASE REMOVAL PUMPTIMER/CONTROLLERWall-mounted Programmable Timeractivates evacuation pump at pre-determined time (1-99 Days).

2 GREASE REMOVAL PUMP evacuates contained GREASE regardless of FLOW CONTROLWITH AIR INTAKE (Not Shown) REMOVABLE BAFFLESECURED COVER (Removed)White acid-resisting coating,gasketed air and watertight,single-bolt,non-skid safety ConnectionsBODYS teel with whiteacid-resisting coatingINTERNALTRAP LEGRECLAIM CHAMBER provides visual evidence thatgrease layer is removed, assuringcorrect interval has been OPTION includes the sensing and alarm probe which enables the use of the probe as the primary source of sensing with the timer as a back-up 3/27/08 11:58 AM Page 205 WARNING: Cancer and Reproductive Harm - INTERCEPTORSINTERCEPTORSThis checklist of interceptors is provided as a guide to selection of the proper type interceptor to control specific waste materials.

3 First determine the waste material to becontrolled, then follow the check marks for the types of interceptors to OrderSelect Type Number from Dimension Table and use suffix numbers to indicate :Series No. 601060106H-EXT-ISIType ,Integral ExtensionOption,Integrated Solids InterceptorHOW TO ORDER INTERCEPTORS WITH EXTENDED TOPSWhen ordering extensions for GREASE and Oil Interceptors (-EXT), specify dimension from the pipe centerline to finished ChecklistTYPE OFWASTEMATERIALTYPES OF INTERCEPTORSGREASE INTERCEPTORSOILSEPARATORSSOLIDS INTERCEPTORSAUTOMATICSEMI-AUTOMATICMANUA LAUTOMATICB ariumPPBenzinePPPPPPC heesePPPPPPPPPPPPPPC utting OilsPPPPPPE lemental Mercury*PFatsPPPPPPPPPPPPPPG asolinePPPPPPG auzePPPG lass GrindingsPGravelPPPPG reasePPPPPPPPPPPPPPHairPPPPJ ewelsPPPK erosenePPPPPLintPPPPPL ubricating OilPPPPPPN aphthaPPPPPPOilPPPPPPOil SludgePParaffinPPPPPPPPPPP lasterPPPrecious MetalsPPPQ uench OilPPPPPPR ougePRubber GrindingsPSandPPPPS edimentPPPPWaxPPPPPPPPPP*Cast Iron Interceptor 3/27/08 11:58 AM Page 206 WARNING.

4 Cancer and Reproductive Harm - INTERCEPTORSGREASE INTERCEPTORSINTERCEPTORSS izingConsult PDI-G101 or ASME Standards or your local TableTYPE & OUTLETSIZE (INCHES)AUTOMATIC TYPE60306A25360307A35360308A50360309A754 60310A100460311A150460312A200660313A2506 60314A350660315A5006 SEMI-AUTOMATIC TYPE60102-SA, -RT, -ET7260103-SA, -RT, -ET10260104-SA, -RT, -ET15260105-SA, -RT, -ET20360106-SA, -RT, -ET25360107-SA, -RT, -ET35360108-SA, -RT, -ET503 SEMI-AUTOMATIC LOW TYPE60115-SA353 GREASE MONITORING DEVICEEGOLD-1000 CEGOLD-2000-SAPTYPE & OUTLETSIZE (INCHES)MANUAL CLEANING TYPE60102H, -EXT, -RT, -ET7260103H, -EXT, -RT, -ET10260104H, -EXT, -RT, -ET15260105H, -EXT, -RT, -ET20360106H, -EXT, -RT, -ET25360107H, -EXT, -RT, -ET35360108H, -EXT, -RT, -ET50360109H, -EXT, -RT, -ET75360110H, -EXT, -RT, -ET1004 MANUAL CLEANING LOW TYPE60115A20260117A353 MANUAL CLEANING HIGH VOLUME TYPE60213A, -EXT150460214A, -EXT200560215A, -EXT250560216A, -EXT350660217A, 3/27/08 11:58 AM Page 207 WARNING.

5 Cancer and Reproductive Harm - Pictorial Selection GuideINTERCEPTORS Pictorial Selection Guide208 INTERCEPTORSAUTOMATICELECTRONIC GREASE /OIL LEVEL DETECTORS60300 AGI-2000A Fully Electronic SS InterceptorPage 21960100H-GRDG rease Removal DevicePage 211 EGOLD-1000 Monitoring Device forInterceptors Inside BuildingPage 220 CEGOLD-2000 Monitoring Device forInterceptors Outside BuildingPage 220 SAPS ensing & Alarm ProbePage 217 MANUAL CLEANING60115A/60117 ALow-BoyPage 21660210 AHigh VolumePage 21760210A-EXTHigh Volume, Extended TopPage 218 MANUAL CLEANING60100 HOn-Floor TypePage 21160100H-EXTE xtended TopPage 21260100H-ETEnclosed TopPage 21260100H-RTRecessed TypePage 213 SEMI-AUTOMATIC CLEANING60100-SAOn-Floor TypePage 21460100-SA-ETEnclosed TypePage 21560100-SA-RTRecessed TypePage 21560115-SALow BoyPage 3/27/08 11:58 AM Page 208 WARNING.

6 Cancer and Reproductive Harm - Pictorial Selection GuideINTERCEPTORS Pictorial Selection Guide209 INTERCEPTORSOIL SEPARATORS60500 BGravity-Type Draw-OffPage 22560500B-EXTE xtended Top, Draw-Off TypePage 22560500-ESTwith External Storage TankPage 226 OIL SEPARATORS60610 AHigh Volume, Draw-Off TypePage 22760610A-EXTHigh Volume, Extended Top, Draw-Off TypePage 22760610-ESTHigh Volume with External Storage TankPage 228 (EST NOT SHOWN)OIL/SEDIMENTLINT INTERCEPTOR60810 Page 22961800 Galvanized Steel BucketPage 232 SOLIDS INTERCEPTORS61000 Barber Shop Type, Bottom AccessPage 22961030 Jewelry Shop Type, Top AccessPage 22961040A18" x 18" Top AccessPage 230610706108010-1/2" Top16-1/2 TopTop AccessPages 230, 3/27/08 11:58 AM Page 209 WARNING: Cancer and Reproductive Harm - INTERCEPTORS GREASE INTERCEPTORSINTERCEPTORST ypical InstallationsThe typical illustrations shown below are suggested ways of installing various types of JOSAM Interceptors.

7 All installations are subject togovernment and local code Series Interceptor on floor, servicing a Series Semi-Automatic shallow Interceptor installed onfloor, servicing a double compartment sink and Series Interceptor installed on floor under sink.(Recommended only if there is adequate head room for coverremoval and service.)NOTE:Install air intake from flow control to outside of building and terminate with elbow, turned down or intersect a local vent or vent stack without trap if permittedby code. Top of air intake from flow control should not be lower than rim of Series Interceptor recessed with deep roughingextended flush with Series Semi-Automatic Interceptor recessed flush withfloor,servicing a Series Interceptor recessed flush with floor, servicing asink and an additional 3/27/08 11:58 AM Page 210 WARNING: Cancer and Reproductive Harm - use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and GREASE (FOG).

8 Adequatespace and head room for removal of cover must be available for manual 60100H Series epoxy coated fabricated steel GREASE Interceptor, no-hub connec-tions, internal trap, removable diffuser baffle, gasketed non-skid cover, flow control fittingand PDI Seal of Approval. Conforms to Plumbing & Drainage Institute Standard to Plumbing and Drainage Institute Standard Options-40 Cover Recess for Floor Finish-61 Flange and Clamp Device* -ISII ntegrated Solids Interceptort-EXTE xtension, 6 Standard.(Specify Extension Height)t-RTRecessed Typet-ETEnclosed Type-HDHeavy-Duty Cover-SSStainless Steel Interceptort-GRD* GREASE Removal Device,60104H-60110H -GRDP GREASE Recovery Devicewith Probe-SAPS ensing and Alarm ProbeAPPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and GREASE (FOG).

9 The GreaseRemoval Device (GRD), with programmable timer, controls the internal pump toremove GREASE on 60100H-GRD Series epoxy coated fabricated steel GREASE Interceptor, no-hubconnections, internal trap, removable baffle, gasketed non-skid cover, flow control fit-ting and PDI Seal of Approval. Programmable timer controls internal pump forremoval of GREASE at predetermined N/A:-ISIGREASE INTERCEPTORSGREASE INTERCEPTORS211 INTERCEPTORSTYPE *-ISI and -GRD cannot be furnished together. 60100H-GRDP meets ANSI SERIESMANUAL CLEANING, ON-FLOOR TYPEtProduct Illustration SERIES with GREASE Removal DeviceTYPE 5/2/08 3:02 PM Page 211 WARNING: Cancer and Reproductive Harm - use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and GREASE (FOG).

10 Extendedtop with fixed extension for installations requiring additional roughing depth fromthe cover of the interceptor to the inlet and 60100H-EXT Series epoxy coated fabricated steel GREASE Interceptor, deeproughing, integral extension, flush-with-floor type, no-hub connections, internal trap,removable diffuser baffle, gasketed non-skid cover, flow control fitting and PDI Seal of to Plumbing and Drainage Institute Standard SERIES with Extension60100H-ET SERIESE nclosed TypeTYPE 60102H-EXT71428-1/49-3/814-7/81317-5/835 60103H-EXT102028-1/29-3/816-5/814-1/217- 7/84560104H-EXT153029-1/29-3/820-3/81718 -7/86060105H-EXT204031210-7/820-7/81922- 7/87060106H-EXT255031310-7/823-3/821-1/2 23-7/89060107H-EXT3570314-1/210-7/826-1/ 82325-3/811060108H-EXT50100316-1/210-7/8 27-7/825-1/227-3/813560109H-EXT751503211 241313322060110H-EXT10020042314473537325 DIMENSIONS BASED ON STD.