Introduction_____The 670 Series Full Circle Sprinklers are designed for irrigation oflarge turf areas such as golf courses, parks, recreational fieldsand school from durable, high strength engineering plastic andstainless steel components, these Sprinklers incorporate manyinnovative and time-proven features for lasting, maintenance-freeoperation. Prior to installing the sprinkler , read through the recommendedinstallation and start-up procedures. Please observe all Warningsand Cautionswhen installing and operating Series Rotary SprinklersInstallation & Service Instructions670 Electric Valve-In-HeadFeatures _____ Four standard pressure regulation settings available toensure consistently accurate nozzle performanceregardless of elevation Four body styles/activation types available to fit everyapplication: Electric VIH, Normally Open Hydraulic VIH,Normally Closed Hydraulic VIH and Check-O-Matic Manual control at the sprinkler , On-Off-Auto (Electricand Normally Closed) Bowl-vented discharge (atmospheric) minimizes the differential pressure required for regulation and ensurespositive valve closure (Electric and Normally Closed) Time-prov

Installation Procedure _____ To assure maximum performance from your 670 Series Rotary Sprinklers, read these instructions completely prior to installation or service.

Tags:

  Series, Rotary, Sprinkler, 670 series rotary sprinklers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 670 Series Rotary Sprinklers - Century Equipment

1 Introduction_____The 670 Series Full Circle Sprinklers are designed for irrigation oflarge turf areas such as golf courses, parks, recreational fieldsand school from durable, high strength engineering plastic andstainless steel components, these Sprinklers incorporate manyinnovative and time-proven features for lasting, maintenance-freeoperation. Prior to installing the sprinkler , read through the recommendedinstallation and start-up procedures. Please observe all Warningsand Cautionswhen installing and operating Series Rotary SprinklersInstallation & Service Instructions670 Electric Valve-In-HeadFeatures _____ Four standard pressure regulation settings available toensure consistently accurate nozzle performanceregardless of elevation Four body styles/activation types available to fit everyapplication.

2 Electric VIH, Normally Open Hydraulic VIH,Normally Closed Hydraulic VIH and Check-O-Matic Manual control at the sprinkler , On-Off-Auto (Electricand Normally Closed) Bowl-vented discharge (atmospheric) minimizes the differential pressure required for regulation and ensurespositive valve closure (Electric and Normally Closed) Time-proven gear drive design All internal components serviceable from the top of thesprinkler Large selection of nozzles available Fixed stator (#70 and #71 nozzle) Variable stator (#72, #73 and #74 nozzle) Durable plastic and stainless steel constructionSpecifications _____ Radius: 70' 102' ( m 31,1 m) Flow Rate: GPM l/mn m3/hr Arc: Full Circle Models: Normally Open Valve-In-Head Check-O-Matic Electric Valve-In-Head Normally Closed Valve-In-Head Maximum Pressure: All Models - 150 PSI ( kg/cm2) ( kPa) Body Height: 11" ( mm) Pop-Up Height: " ( cm) Pop-Up to Nozzle: 1" ( mm) Trajectory: 25 " NPT or BSP Female Thread Inlet Solenoid: 24 VAC, 50/60 Hz Inrush Current:50 Hz, Amps ( VA)60 Hz, Amps ( VA) Holding Current: 50 Hz, Amps ( VA)60 Hz, Amps ( VA) Manual Control.

3 On-Off-Auto Check-O-Matic model checks up to 37' ( m) Information _____2 Square SpacingNo Wind 55% of diameter4 50% of diameter8 45% of diameterTriangular SpacingNo Wind 60% of diameter4 55% of diameter8 50% of diameterSingle Row SpacingNo Wind 50% of diameter4 50% of diameter8 45% of diameterConversion Information All gallons per minute shown are To convert to Imperial gallons per minute, multiply by .833. To convert to liters per minute, multiply by To convert pounds per square inch (PSI) to atmospheres,divide by To convert pounds per square inch (PSI) to kilograms persquare centimeter (kg/cm2) divide by To convert feet to meters, divide by To convert inches to millimeters, multiply by NOZZLE PERFORMANCE METRIC kPa = kilo PascalsRad = metersl/mn = liters per minutem3/hr - cubic meters per hour = Pressure Regulation Models = Nozzles not recommended at this pressureRad = feetGPM = gallons per minute = Pressure regulation = Nozzles not recommended at this SETNOZZLE SET NOZZLE SETNOZZLE SETNOZZLE NOZZLE PERFORMANCE SETNOZZLE SET NOZZLE SETNOZZLE SETNOZZLE SETPRESSURE7071727374kg/cm2kPaRadl/mn m3/hr Radl/mn m3/hrRadl/mn m3/hr Radl/mn m3/hrRadl/mn m3 Spacing of

4 SprinklersOrdering Information _____Note: Pressure regulation available on Electric and Normally Closed Valve-In-Head models XArcBody / ValveNozzlePres. = Full Circle01 = NPT, NO Valve-In-Head705 = 50 PSI02 = NPT, Check-O-Matic716 = 65 PSI06 = NPT, Electric Valve-In-Head728 = 80 PSI08 = NPT, NC Valve-In-Head731 = 100 PSI51 = BSP, NO Valve-In-Head7452 = BSP, Check-O-Matic56 = BSP, Electric Valve-In-Head58 = BSP, NC Valve-In-HeadInstallation Procedure _____To assure maximum performance from your 670 series rotary sprinklers ,read these instructions completely prior to installation or Swing Joints1. Construct or provide triple swing joints for each sprinkler as shown inFigure 1. Use PVC or ABS pipe nipple for sprinkler :On sites where the possibility of heavy Equipment rollingover a sprinkler exists, the swing joint will flex preventing damage tothe lateral or main lines.

5 On a new installation in raw ground wherethe Sprinklers are to be initially installed above the finished grade andlowered when new turf is established, the swing joint allows sprinklerrepositioning without changing risers. This is a common and practi-cal procedure which eliminates the problem of dirt being accidentallyintroduced into the lateral lines when a riser is Flush lines thoroughly prior to installing Apply Teflon tape on riser threads. Install sprinkler to riser only Teflon tape on riser threads. Use of pipe dope or othertypes of sealing compounds can cause deterioration of sprin-kler body Electric Control Wires1. Route control wires to sprinkler location(s). Provideenough extra wire at sprinkler to allow for movement ofsprinkler without straining wire connections.

6 One commonwire and station wire is required for each sprinkler . SeeWire Sizing Chart, Table 1for proper Attach control wires to solenoid leads using an approvedwaterproof splicing wire connections must be waterproofed to pre-vent short circuit to ground and subsequent con-troller Hydraulic Control Tubing1. Route control tubing from controller to sprinkler location(s).NOTE: Leave an 18" (45,7 cm) service loop of tubing at eachsprinkler to facilitate movement of sprinkler and serviceoperations. Tubing runs in excess of 1,000' (304,8 m) are not advis-able due to delayed response time. The valve elevation for normally open valve-in-headsystems should not exceed 25' (7,6 m) above controllerelevation or 70' (21,3 m) below controller elevation. The valve elevation for normally closed valve-in-headsystems should not exceed 0' above controller elevationor 70' (21,3 m) below controller elevation.

7 If connecting more than one VIH sprinkler per control tub-ing run, refer to the chart below. 2. Flush tubing thoroughly to remove all air and Remove tube retainer and poly cap from tubing adapter at base of Slide tube retainer over control tubing and attach tubing to adapter. 5. Slide tube retainer over adapter area to secure 1 Triple Swing Joints7 5 0 S E R I E ST U R F S P R I N K L E RO F F A U T O O NWIRE NUMBERSIZEOF VALVESCONTROLCOMMON123423 VAC14142348101254935323 VAC14122890123967343323 VAC14103378144878650523 VAC12123759160487356123 VAC121045911973107168823 VAC12854112328126381223 VAC101059452555138789224 VAC14142765130984654924 VAC141233931608103967324 VAC141039621877121378324 VAC121243942082134687224 VAC1210539725571652107124 VAC128636430181949126324 VAC10106986331121401387 Table 1: Wire Sizing ChartMaximum allowable length in feet from controller to electric based on the followingTransformer - 115/230 VAC - 24 VAC, 45 VACoil 24 VAC, 60 HzHolding.

8 30 AmpsIn Rush- .40 AmpsRecommendedMaximum1" " VIH23 OUTPUTVOLTAGE ATCONTROLLERTRANSFORMER34 System Start-UpThe following is a recommended procedure that will protect system components during system start-up. The procedure isbased on a velocity fill rate of less than 2' ( m) per second. See Table 2 Use jockey pump only to fill system at velocity fill rate of less than 2' ( m) per Use quick coupler keys at all tees and greens with quick coupler valves to bleed air from system lines during fillingprocess. Do not compress air and then relieve, bleed air while filling After water has filled all lines and all air is removed, remove quick coupler to comply with recommended fill rate will increase line pressure resulting in a water hammer effectthat could damage 2 Recommended System Fill RatePilot Valve Operation (Models 674-X6-XXX and 674-X8-XXX Only)The main function of the pilot valve is to control the operation of the main valve located in the base of the sprinkler main valve is operated by the release of water metered through the pilot valve when it is activated either manually atthe sprinkler or by the irrigation system important function of the pilot valve is to regulate the water pressure to the sprinkler nozzle.

9 Pressure regulationcompensates for large variations within the system and maintains a constant pressure for optimum sprinkler operation. Thepilot valve is factory set to regulate one of four pressure levels 50 PSI ( kg/cm2), 65 PSI ( kg/cm2), 80 PSI ( kg/cm2)or 100 PSI ( kg/cm2).NOTE: Sprinklers built between 1986 and 1988 utilized an adjustable pilot valve assembly. Although factory-set at 100 PSI( kg/cm2) regulating pressure, the pilot valve can be set to regulate between 40 120 PSI ( kg/cm2) to compen-sate for various field conditions. See Adjusting Pressure Regulation on page 11 for more sprinkler operation mode is set using a Toro Selector Tool (P/N 995-15) inserted through the body flange onto the pilotvalve D-shaped selector cam. The "AUTO" mode permits automatic operation from the system controller.

10 The "ON" modeopens the main valve for manual operation and "OFF" mode prevents the main valve from TO HIGH OPERATING PRESSURE, NEVER STAND OR LEAN DIRECTLY OVERSPRINKLER OR COME IN CONTACT WITH SPRAY WHEN ACTUATING sprinkler MANU-ALLY OR AUTOMATICALLY. PRIOR TO ACTUATION OF sprinkler , USE A SLOT HEADSCREWDRIVER TO LIFT CAP TO OBSERVE DIRECTION OF NOZZLE. FAILURE TO COM-PLY MAY RESULT IN SERIOUS TO HIGH OPERATING PRESSURE, NEVER STAND OR LEAN DIRECTLY OVER TOP OFSPRINKLER OR COME IN CONTACT WITH SPRAY. FAILURE TO COMPLY MAY RESULT INSERIOUS SizeFlowVelocityPipe Troubleshooting Pilot ValvePossible Equipment failures with causes and corrective action are listed CAUSE CORRECTIVE will not turn on(a) No 24 VAC to coil assembly. (Electric Models) Measure voltage with a Digital Volt Meter (DVM).