6F EYSR Retrofit Sealing Fitting Cl. I, Div. 2, Groups …

US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2019 Eaton1225F5 FEYSR retrofitsealing fittingsCl. I, Div. 2, Groups C, DCl. II, Div. 2, Groups E, F, GExplosionproofDust-ignitionproofApplica tions:EYSR Retrofit Sealing fittings are installed: In rigid metal conduit systems in Class I, Division 2 hazardous locations To replace installed Eaton s Crouse-Hinds series EYS or EYD Sealing fittings Without disassembly of the conduit system In vertical or horizontal positions, indoors or outdoors To restrict the passage of gases, vapors or flames from one portion of the electrical system to another at atmospheric pressures and normal ambient temperatures To limit explosions to the sealed off enclosure To limit pre-compression or pressure piling in the conduit system To prevent accumulation of water in the conduit system when installed with an ECD15 drainFeatures.

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2015 Eaton’s Crouse-Hinds Business 6F 6F EYSR Retrofit Sealing Fitting Chico Sealing ...

Tags:

  Fitting, Leasing, Retrofit, Srey, 6f eysr retrofit sealing fitting cl, 6f eysr retrofit sealing fitting

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 6F EYSR Retrofit Sealing Fitting Cl. I, Div. 2, Groups …

1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2019 Eaton1225F5 FEYSR retrofitsealing fittingsCl. I, Div. 2, Groups C, DCl. II, Div. 2, Groups E, F, GExplosionproofDust-ignitionproofApplica tions:EYSR Retrofit Sealing fittings are installed: In rigid metal conduit systems in Class I, Division 2 hazardous locations To replace installed Eaton s Crouse-Hinds series EYS or EYD Sealing fittings Without disassembly of the conduit system In vertical or horizontal positions, indoors or outdoors To restrict the passage of gases, vapors or flames from one portion of the electrical system to another at atmospheric pressures and normal ambient temperatures To limit explosions to the sealed off enclosure To limit pre-compression or pressure piling in the conduit system To prevent accumulation of water in the conduit system when installed with an ECD15 drainFeatures.

2 Seal may be installed in the existing conduit run without disassembly of the conduit system, saving time and labor Overall length and spacing requirements do not exceed those of standard EYS seals; permits close nesting of seals Pipe plugs permit the installation of a standard ECD15 drain Fitting (ordered separately) for use in vertical conduit runs to drain any water that might accumulate in the conduit system Steel set screws provide grounding continuity Suitable for vertical and horizontal installations for indoor and outdoor applications Available in 3/4 to 4 NPT sizesStandard materials: Body Feraloy iron alloy Pipe plugs, bolts and set screws steel Gasket neopreneStandard finishes: Feraloy iron alloy electrogalvanized and aluminum acrylic paint Steel electrogalvanized Gasket naturalCertifications and compliances:NEC: Class I, Division 2, Groups C, D Class II, Division 2, Groups E, F, GCEC: Class I, Division 1, Groups C, D Class II, Division 1, Groups E, F, GUL standard.

3 UL1203 CSA standard: No. 30 EYSR Sealing fittings are approved for use in hazardous locations only when Chico A Sealing compound and Chico X fiber are used to make the the approximate internal volume in cubic inches to determine how much Chico A Sealing compound is (in inches):Ordering information:See pages 124-125 forChico Sealing compound and fiberApproximate internal volume in cubic inchesAApproximate amount (oz.) of fiber per hubHub sizeCat. #VerticalHorizontalVerticalHorizontal3/4 EYSR231/253/41/161/81 EYSR343/491/21/81/411/4 EYSR47131/21/41/211/2 EYSR5121/4241/41/212 EYSR6253/4401/21221/2 EYSR748751/211/233 EYSR8861/21262431/2 EYSR914721041/294 EYSR1018625241/29 Hub sizeABC3/4 311/1621/211/21 43/831/831/811/4 533/8311/2 51/435/832 61/44321/2 71/2537/83 81/251/241/431/2 913/6461/1643/44 93/465/851/4