Example: biology

700/3000 VA User's Guide - Power management solutions | …

eaton 9130 UPS. 700/3000 VA. User's Guide eaton 9130 UPS. 700/3000 VA. User's Guide Requesting a Declaration of Conformity Units that are labeled with a CE mark comply with the following harmonized standards and EU directives: l Harmonized Standards: EN 62040-1-1 and EN 62040-2; IEC 60950-1. l EU Directives: 73/23/EEC, Council Directive on equipment designed for use within certain voltage limits 93/68/EEC, Amending Directive 73/23/EEC. 2004/108/EEC, Council Directive relating to electromagnetic compatibility The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the EC. Declaration of Conformity, contact: eaton Power Quality Oy Koskelontie 13.

Eaton 9130 700/3000 VA UPS User’s Guide 164201718—Rev 8 1 Chapter 1 Introduction The Eaton® 9130 uninterruptible power system (UPS), protects your sensitive electronic equipment from the most common power problems, including power failures, power sags, power surges, brownouts, line noise,

Tags:

  Power, Eaton, Uninterruptible, Uninterruptible power

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 700/3000 VA User's Guide - Power management solutions | …

1 eaton 9130 UPS. 700/3000 VA. User's Guide eaton 9130 UPS. 700/3000 VA. User's Guide Requesting a Declaration of Conformity Units that are labeled with a CE mark comply with the following harmonized standards and EU directives: l Harmonized Standards: EN 62040-1-1 and EN 62040-2; IEC 60950-1. l EU Directives: 73/23/EEC, Council Directive on equipment designed for use within certain voltage limits 93/68/EEC, Amending Directive 73/23/EEC. 2004/108/EEC, Council Directive relating to electromagnetic compatibility The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the EC. Declaration of Conformity, contact: eaton Power Quality Oy Koskelontie 13.

2 FIN-02920 Espoo Finland Phone: +358-9-452 661. Fax: +358-9-452 665 68. eaton , FERRUPS, and Intelligent Power Protector are registered trademarks of eaton or its subsidiaries and affiliates. National Electrical Code and NEC are registered trademarks of National Fire Protection Association, Inc. Phillips is a registered trademark of Phillips Screw Company. All other trademarks are property of their respective companies. Copyright 2011 2015 eaton , Raleigh, NC, USA. All rights reserved. No part of this document may be reproduced in any way without the express written approval of eaton . Class A EMC Statements FCC Part 15. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.

3 These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense EN 62040-2. Some configurations are classified under EN 62040-2 as Category C2 UPS. For these configurations, the following applies: WARNING. This is a category C2 UPS product.

4 In a residential environment, this product may cause radio interference, in which case the user may be required to take additional measures. Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol. CAUTION: REFER TO OPERATOR'S MANUAL - Refer to your operator's manual for additional information, such as important operating and maintenance instructions. This symbol indicates that you should not discard the UPS or the UPS. batteries in the trash. This product contains sealed, lead-acid batteries and must be disposed of properly.

5 For more information, contact your local recycling/reuse or hazardous waste center. This symbol indicates that you should not discard waste electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center. Table of Contents 1 INTRODUCTION .. 1. 2 SAFETY WARNINGS .. 3. 3 INSTALLATION .. 13. Inspecting the Equipment .. 13. Unpacking the Cabinet.. 13. Checking the Accessory Kit .. 14. Rackmount Installation .. 14. Checking the Rail Kit Accessories .. 14. Tools Required .. 15. Rackmount Setup .. 15. Rackmount Wiring Installation .. 18. Installing the UPS .. 18. Connecting the EBM(s) .. 20. Tower Installation .. 22.

6 Tower Wiring Installation .. 22. Installing the UPS .. 22. Connecting the EBM(s) .. 24. UPS Initial Startup .. 26. 4 OPERATION.. 29. Control Panel Functions .. 29. Changing the Language.. 30. Display Functions .. 30. User Settings.. 31. Operating Modes .. 34. Normal Mode .. 34. Battery Mode .. 34. Bypass Mode .. 34. Standby Mode .. 35. UPS Startup and Shutdown .. 35. Starting the UPS .. 35. Starting the UPS on Battery .. 35. UPS Shutdown .. 36. Transferring the UPS Between Modes .. 36. Retrieving the Event Log .. 36. Logic Power Off.. 36. Setting Power Strategy .. 37. Configuring Bypass Settings .. 37. Configuring Load Segments .. 38. Configuring Battery Settings .. 38. Configuring the UPS for EBMs.

7 38. Running Automatic Battery Tests .. 39. Configuring Automatic Restart .. 39. eaton 9130 700/3000 VA UPS User's Guide 164201718 Rev 8 i Table of Contents 5 COMMUNICATION .. 41. Installing Communication Options and Control Terminals.. 41. Communication Options .. 42. RS-232 and USB Communication Ports .. 42. Connectivity Cards .. 43. Remote Emergency Power -off .. 43. Forced to Bypass State .. 44. Relay Output Contacts .. 45. Programmable Signal Inputs .. 46. Power management and Protection Software .. 46. 6 MAINTENANCE.. 47. UPS and Battery Care .. 47. Storing the UPS and Batteries.. 47. When to Replace Batteries .. 47. Replacing Batteries .. 47. Replacing Rackmount UPS Internal Batteries.

8 48. Replacing Tower UPS Internal Batteries .. 50. Replacing Rackmount EBMs .. 53. Replacing Tower EBMs .. 54. Testing New Batteries.. 55. Recycling the Used Battery or UPS.. 55. Updating the UPS Firmware .. 55. 7 SPECIFICATIONS .. 57. Rear Panels .. 73. 8 TROUBLESHOOTING.. 89. Typical Alarms and Conditions .. 89. Alarm or Condition .. 89. Silencing the Alarm .. 91. Service and Support .. 92. 9 WARRANTY .. 93. ii eaton 9130 700/3000 VA UPS User's Guide 164201718 Rev 8. Chapter 1 Introduction The eaton 9130 uninterruptible Power system (UPS), protects your sensitive electronic equipment from the most common Power problems, including Power failures, Power sags, Power surges, brownouts, line noise, high voltage spikes, frequency variations, switching transients, and harmonic distortion.

9 Power outages can occur when you least expect it and Power quality can be erratic. These Power problems have the potential to corrupt critical data, destroy unsaved work sessions, and damage hardware causing hours of lost productivity and expensive repairs. With the eaton 9130, you can safely eliminate the effects of Power disturbances and guard the integrity of your equipment. Providing outstanding performance and reliability, the eaton 9130's unique benefits include: l True online double-conversion technology with high Power density, utility frequency independence, and generator compatibility. l Advanced Battery management (ABM )technology that uses advanced battery management to increase service life, optimize recharge time, and provide a warning before the end of useful battery life.

10 L Selectable High Efficiency mode of operation. l Rackmount models in a space-optimizing 2U size that fits any standard 19" rack. l Standard communication options: one RS-232 communication port, one USB communication port, and relay output contacts. l Optional connectivity cards with enhanced communication capabilities. l Extended runtime with up to four Extended Battery Modules (EBMs) per UPS. l Firmware that is easily upgradable without a service call. l Emergency shutdown control through the Remote Emergency Power -off (REPO) port. l Backed by worldwide agency approvals. Figure 1 shows the eaton 9130 rackmount UPS, and Figure 2 shows the optional rackmount EBM. Figure 1. The eaton 9130 Rackmount UPS.


Related search queries