Transcription of 7Series Instructions for Use
1 Dental wings7 SeriesInstructions for UseOriginalInstructions for UseModel DW-7-140 CONTENTS1. About this License, trademarks and other rights62. Introduction and Intended Device description and Accessories and products used in Compatibility Further Scope of Disposal123. Installation144. Basic principles and user Starting scanner and User interface195. Scanning Step-by-step scanning instructions226. Calibration (pre-use check) Cleaning and Service327. Troubleshooting338. Packing the scanner349. Distributors and service3510. Technical data and label3611. Explanation of symbols42EU Declaration of Conformity441. About this guideThese Instructions for Use are valid for the product life cycle of your device and its software unless new Instructions arepublished within this provided Instructions contain important information on the safe and appropriate use of your scanner and itssoftware.
2 Make sure to have read and understood this document prior to working with the device. In case ofquestions, contact your keep this document for future Instructions for UseInstructions for Use for your scanner are provided in electronic form. They are stored on your , DentalWings Instructions for Use may be accessed from our IFU website at: DisclaimerThis device is designed for use by persons who have appropriate knowledge in dentistry and dental user of this device is solely responsible for determining whether or not this device is suitable for a particularpatient case and circumstances. The user is solely responsible for the correctness, completeness and adequacyof alldataentered into this device and the provided software.
3 The user has to check the correctness and accuracyof the results and to assess each Wings products must be used in accordance with their accompanying Instructions for use. Improper useor handling of DentalWings products willvoid the warranty, if any, given for DentalWings products. If you requireadditional information on the proper use of Dental Wings products, contact your local distributor. The user is notallowed to modify DentalWings WINGS, ITS AFFILIATES OR DISTRIBUTORS DISCLAIM REPRESENTATIONS AND WARRANTIES OF ANYKIND, WHETHER EXPRESSED OR IMPLIED, WRITTEN OR ORAL, WITH RESPECT TO THE PRODUCTS, INCLUDINGANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, ERROR-FREE OPERATION ORNON-INFRINGEMENT, AND THE PRODUCTSARE SOLD ASIS.
4 CHAPTER 1 |7 Series Instructions for Use5 Our maximum liability arising out of the products or their use, whether based upon warranty, contract, tort orotherwise, shall not exceed the actual payments received by us in respect of the purchase price thereof. In noevent shall we be liable for special, incidental or consequential damages, including, but not limited to, loss ofprofits, loss of dataor loss of use damages, arising hereunder or from the sale of the to hardware and software components are made regularly. Therefore, some of the Instructions ,specifications and pictures contained in these Instructions for Use may differ slightly from your particularsituation. Dental Wings reserves the right to revise or make changes or improvements to this product ordocumentation at any time without obligation to notify any person of such revisions or improvements.
5 The useris obliged to study the latest developments party products and product dataWhen scanning and designing cases, the user may work with third party products and/or product data. DentalWings, its subsidiaries, or distribution partners disclaim any liability for damages in connection with or arisingfrom such third party product dataor products being used within this License, trademarks and other rightsSoftware licensesYour scanner software is protected by a license agreement and may be used or copied only in accordance withthe terms of this agreement. It is illegal to copy or use the software on any medium except those permitted in thelicense of the software applications may require an additional license key.
6 Contact your local distributor for of the products and accessories mentioned in these Instructions for Use may not be available in names and trademarksDentalWings, DWOS and coDiagnostiX are trademarks or registered trademarks of 1 |7 Series Instructions for UseAll other trademarks and logos mentioned in this document are trademarks, registered trademarks or logos oftheir respective Wings documents may not be reprinted or published, in whole or in part, without the written authorizationof 1 |7 Series Instructions for Use72. Introduction and Intended useThe 7 Series is intended to be used by dental laboratory professionals as dental 3D scanner for positive andnegative models (impressions).
7 Device description and featuresThis device is an optical3D variants and configurationThe device is delivered in the following variants and configuration:nWith the distributor logo and colornWith adistributor-specific set of accessoriesnWith adistributor-specific software configurationnWith acountry-specific power cordnWith or without standard PCperipheralsIf standard PC peripherals are not included in the delivery, the following items will be required to use thescanner as intended:nMonitor (21 inches)with DVI, VGA or HDMI ports and aminimum screen resolution of 1600 X1080 pixelsnKeyboard (USB or PS/2)nTwo-button mouse with scrollwheel(USB or PS/2)nNetwork cable (RJ45)nUninterruptible power supply to protect against power interruption and voltage fluctuation;for the operatingvoltage of your device seeTechnical data and label ( ).
8 8 CHAPTER 2 |7 Series Instructions for UseThe multi-die holder contains mounting putty to hold the dies. You may replace the delivered mounting putty withan equivalent materialwhich:nis non-reflecting, non-staining, non-toxic, removable without tracenhas sufficient plasticity in the operating temperature rangePrinciples of operationCases scanned and designed with DWOSare called "order". The order number is aunique identifier used to identifythe order and manage the case during the entire process. Generation of such order number is the first of fourmain steps most commonly used in the four main steps are:1. Creating the order(see Step-by-step scanning Instructions , p. 22)2. Scanning the physicalmodelto create adigital3D model(see Step-by-step scanning Instructions , p.)
9 22)3. Designing the restoration4. Exporting the order for production (choose between in-house and out-sourced production)For complete software Instructions , refer to DWOSUser Accessories and products used in combinationOnly use accessories specified by the manufacturer. A list of accessories and products which may be used incombination with this scanner is included in chapterTechnical data and label ( ).The scanner scans alllambertian materials. Scanning accuracy has been validated with the materialLeanRock XL5(Whip Mix Corporation). Other plaster, wax-up and impression materials may, in principle, be suitable as , the user has to validate their compatibility with the device. Surface coating may improve thescannability of the note, the scanner is available in different configurations.
10 For device variants and optional PC peripherals,see chapterDevice variants and configuration ( ). Information on distributor specific accessory sets can beobtained from your 2 |7 Series Instructions for IndicationsThe scanner is a non-contact optical 3D scanning device for use in dental laboratories or dental practice. Thedevice is designed for use by persons who have appropriate knowledge in dentistry and dental laboratorytechnology. Users must also have basic skills to operate a computer. The device combines laser triangulationtechnology with free movement of axes and scans both positive and negative models (impressions). Thesoftware digitally replicates the obtained dataon the ContraindicationsThe scanner is not intended to be used in direct contact with the patient nor is it intended to be used with life-sustaining PrecautionsThis scanner is capable of very precise scanning.