US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds BusinessARK- trol Electrical ConnectorsRPX "Time Slot" Delayed Action ConnectorsHazardous LocationsCl. I, Div. 1 and 2, Group D*ExplosionproofRaintightDimensions see page 1454 Applications:RPX "Time-Slot" delayed actionconnectors are used: In areas which are hazardous due to thepresence of gasoline or gases or vaporsof equivalent hazard (comparable toNEC Class I, Group D), whereconstruction and test procedures arerequired to meet applicable sections ofMIL-STD-810E For connection of devices ranging fromsimple lighting units, power tools andsimilar portables requiring only a powercircuit to sophisticated control andinstrumentation assemblies requiringdisconnectFeatures:The same basic features, described indetail for RPC and RPE Connectors , applyto RPX Connectors as well and include thefollowing: High-strength impact extrudedaluminum shell parts "Tri-Disc" insert assemblies Contacts snap in after termination Positive polarization Interchangeability of inserts in each shellsize Grounding contacts, where used, makefirst and break last The RPX "Time-Slot" delayed actionfeature prevents complete withdrawal ofthe plug in one continuous movement,eliminating the possibility of a circuit-breaking arc occurring in a hazardousarea.

1448 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business ARK-trol® Electrical Connectors RPX "Time Slot" Delayed Action Connectors

Tags:

  Electrical, Industreis, Cooper industries, Cooper, Connectors, Trol, 8p ark trol electrical connectors, Ark trol, 174 electrical connectors

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 8P ARK-trol Electrical Connectors - Cooper Industries

1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds BusinessARK- trol Electrical ConnectorsRPX "Time Slot" Delayed Action ConnectorsHazardous LocationsCl. I, Div. 1 and 2, Group D*ExplosionproofRaintightDimensions see page 1454 Applications:RPX "Time-Slot" delayed actionconnectors are used: In areas which are hazardous due to thepresence of gasoline or gases or vaporsof equivalent hazard (comparable toNEC Class I, Group D), whereconstruction and test procedures arerequired to meet applicable sections ofMIL-STD-810E For connection of devices ranging fromsimple lighting units, power tools andsimilar portables requiring only a powercircuit to sophisticated control andinstrumentation assemblies requiringdisconnectFeatures:The same basic features, described indetail for RPC and RPE Connectors , applyto RPX Connectors as well and include thefollowing: High-strength impact extrudedaluminum shell parts "Tri-Disc" insert assemblies Contacts snap in after termination Positive polarization Interchangeability of inserts in each shellsize Grounding contacts, where used, makefirst and break last The RPX "Time-Slot" delayed actionfeature prevents complete withdrawal ofthe plug in one continuous movement,eliminating the possibility of a circuit-breaking arc occurring in a hazardousarea.

2 Details of operation are shown inthe illustrations Turn plug clamping nutcounterclockwise 45 to unlock Pull to disengage pin and socketcontacts, breaking circuit while contactsare still inside the receptacle. Anyresulting Electrical arc is quenched withinthe receptacle Turn plug clamping nut an additional45 counterclockwise to the releaseposition, thereby effecting delayed Disengage plug and Materials: Back boxes and adapters Feraloy ironalloy Plug, receptacle and cord connectorshells impact extruded aluminum Insulation diallyl phthalate (DAP) Sealing wafer silicone rubber Contacts hard drawn copperStandard Finishes: Feraloy zinc electroplate and aluminumacrylic paint Impact extruded aluminum hard coatanodized Diallyl phthalate natural (blue) Silicone rubber natural (grey)Options:The following options available for RPCand RPE Connectors are also applicable to RPX Connectors . For complete detailssee pages 1431 1432 Alternate polarities ungrounded andgrounded Connectors Crimp type contacts Wire mesh cord gripElectrical Rating Ranges: 10, 20, 30 and 60 amperes 50 to 400 hertz 250, 480 and 600 VAC See listings for specific ratingsCertifications andCompliances: RPX delayed action Connectors have thesame physical properties, characteristicsand environmental capabilities of RPCand RPE Connectors .

3 For detailedinformation on these properties, refer tosee page 1432. In addition to these properties, the"Time-Slot" delayed action featurepermits disconnect under full rated loadwith no possibility of an exposed arc,thus meeting the stringent requirementsof Military Specifications MIL-STD-810E*RPX series are suitable for hazardous areas due to thepresence of gasoline or other gases or vapors ofequivalent hazard (comparable to Class I, GroupD), where construction and test procedures are requiredto meet applicable sections of MIL-STD-810E. For use on systems less than 60 hertz the receptacles,plugs and Connectors are for disconnect use US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds BusinessPOWERC ircuitDescriptionContactSizeAmpsVolts(VA C)ShellSizeHubSize (In.)Square Flanged Receptacle,Dust Cap and Back BoxCat. # (For Surface Mounting) 20 ampsGrounded4w, 5p#12204800173/4 RPX217 914 S09A EDSC2711 RPX217 914 S09A EDSC371 Ungrounded5w, 5p#12204800173/4 RPX217 914 S08N EDSC2711 RPX217 914 S08N EDSC37130 ampsGrounded2w, 3p#10304800173/41 RPX217 914 S02A EDSC3713w, 4p#10304800173/4 RPX217 914 S04A EDSC2711 RPX217 914 S04A EDSC3714w, 5p#10304800213/4 RPX221 914 S17A EDSC2711 RPX221 914 S17A EDSC371 Ungrounded3w, 3p#10304800173/4 RPX217 914 S01N EDSC2711 RPX217 914 S01N EDSC3714w, 4p#10304800173/4 RPX217 914 S03N EDSC2711 RPX217 914 S03N EDSC3715w, 5p#10304800213/4 RPX221 914 S16N EDSC2711 RPX221 914 S16N EDSC371 Special Purpose ; ARK-trol Electrical ConnectorsRPX "Time-Slot" Delayed Action ConnectorsWith Solder Well Terminals , Hazardous Areas*Cl.

4 I, Div. 1 & 2, Group D*ExplosionproofRaintightDimensions see page US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds BusinessCableDiameter RangeCordConnectorCat. # PlugCat. # .250 to .625 RPX317 160 S09 ARPX117 150 to .875 RPX317 161 S09 ARPX117 151 to .625 RPX317 160 S08 NRPX117 150 to .875 RPX317 161 S08 NRPX117 151 to .625 RPX317 160 S02 ARPX117 150 to .875 RPX317 161 S02 ARPX117 151 to .625 RPX317 160 S04 ARPX117 150 to .875 RPX317 161 S04 ARPX117 151 to 161 S17 ARPX121 151 to 395 S17 ARPX121 387 to .625 RPX317 160 S01 NRPX117 150 to .875 RPX317 161 S01 NRPX117 151 to .625 RPX317 160 S03 NRPX117 150 to .875 RPX317 161 S03 NRPX117 151 to 161 S16 NRPX121 151 to 395 S16 NRPX121 387 P16N For alternate polarizations, see page 1431, "Options"section. Solder well terminals provided as standard. Crimpcontacts are optionally available, add suffix T to catalognumber.

5 Example: RPX217-914-S09AT-EDSC271. For square flanged receptacle withoutdust cap,change the middle three digits of the catalog numberfrom 914 to 913. Example: RPX217-913-S09A-EDSC271. For plugs and cord Connectors :Liquidtight/Conduit Adapter To order with adapter, add letters "LT" to first section ofcatalog number. Example: Cable Strain Relief Options Stainless steel wire mesh grip To order, add letter "K"to first section of catalog number. Example: Purpose ; ARK-trol Electrical ConnectorsRPX "Time-Slot" Delayed Action ConnectorsWith Solder Well Terminals, Hazardous Areas*Cl. I, Div. 1 & 2, Group D*ExplosionproofRaintightDimensions see page 14548P*RPX series are suitable for hazardous areas due to the presence of gasoline or other gases or vapors of equivalent hazard (comparable to Class I, Group D), where construction andtest procedures are required to meet applicable sections of MIL-E-5272C and US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds BusinessPOWERC ircuitDescriptionContactSizeAmpsVolts(VA C)ShellSizeHubSize (In.)

6 Square Flanged Receptacle,Dust Cap and Back BoxCat. # (For SurfaceMounting) 60 AmpsGrounded3w, 4p#46060003311/4 RPX233 914 S08A CES424w, 5p#46048003311/4 RPX233 914 S09A CES42 Ungrounded4w, 4p#46060003311/4 RPX233 914 S05N CES425w, 5p#46048003311/4 RPX233 914 S06N CES42 CONTROL6w, 7p#12204800173/4 RPX217 914 S06A EDSC2711 RPX217 914 S06A EDSC3717w, 7p#12204800173/4 RPX217 914 S05N EDSC2711 RPX217 914 S05N EDSC37118w, 19p#12202500213/4 RPX221 914 S08A EDSC2711 RPX221 914 S08A EDSC37119w, 19p#12202500213/4 RPX221 914 S09N EDSC2711 RPX221 914 S09N EDSC37138w, 39p#122025003311/4 RPX233 914 S19A CES4239w, 39p#122025003311/4 RPX233 914 S17N CES42 Special Purpose ; ARK-trol Electrical ConnectorsRPX "Time-Slot" Delayed Action ConnectorsWith Solder Well Terminals , Hazardous Areas*Cl. I, Div. 1 & 2, Group D*ExplosionproofRaintightDimensions see page US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business For alternate polarizations, see page 1431, "Options"section.

7 Solder well terminals provided as standard. Crimpcontacts are optionally available, add suffix T to catalognumber. Example: RPX217-914-S09AT-EDSC271. For square flanged receptacle withoutdust cap, changethe middle three digits of the catalog number from 914 to913. Example: RPX217-913-S09A-EDSC271. For plugs and cord Connectors :Liquidtight/Conduit Adapter To order with adapter, add letters "LT" to first section ofcatalog number. Example: Cable Strain Relief Options Stainless steel wire mesh grip To order, add letter "K"to first section of catalog number. Example: RPXK317-160-S09A.*RPX series are suitable for hazardous areas due to the presence of gasoline or other gases or vapors of equivalent hazard (comparable to Class I, Group D), where construction andtest procedures are required to meet applicable sections of MIL-E-5272C and Purpose ; ARK-trol Electrical ConnectorsRPX "Time-Slot" Delayed Action ConnectorsWith Solder Well Terminals, Hazardous Areas*Cl.

8 I, Div. 1 & 2, Group D*ExplosionproofRaintightDimensions see page 14548 PCableDiameter RangeCordConnectorCat. # PlugCat. # .875 to 163 S08 ARPX133 153 to 396 S08 ARPX133 388 to 397 S08 ARPX133 389 to 163 S09 ARPX133 153 to 396 S09 ARPX133 388 to 397 S09 ARPX133 389 to 163 S05 NRPX133 153 to 396 S05 NRPX133 388 to 397 S05 NRPX133 389 to 163 S06 NRPX133 153 to 396 S06 NRPX133 388 to 397 S06 NRPX133 389 to .625 RPX317 160 S06 ARPX117 150 to .875 RPX317 161 S06 ARPX117 151 to .625 RPX317 160 S05 NRPX117 150 to .875 RPX317 161 S05 NRPX117 151 to 161 S08 ARPX121 151 to 395 S08 ARPX121 387 to 161 S09 NRPX121 151 to 395 S09 NRPX121 387 to 163 S19 ARPX133 153 to 396 S19 ARPX133 388 to 163 S17 NRPX133 153 to 396 S17 NRPX133 388 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds BusinessCord Connector ReceptacleShell Typeand Sizea b *CES42* PlugRPX PlugShell Typeand Sizea b Connectors SquareFlanged Receptacle with Dust CapRPX Connectors SquareFlanged Receptacle with Dust CapShell Typeand BoxesBack BoxesCat.

9 #hlEDSC2717/813/16 EDSC371115/16 Dimension "f"; for #16, #12 and #10 contacts for #4 contacts. These dimensions are approximate and vary with cable size.*CES42 takes 60 ampere receptacle Cord Connector ReceptacleDimensionsIn Inches:8 PARK- trol Electrical ConnectorsRPX "Time-Slot" Delayed ActionConnectors


Related search queries