Example: bachelor of science

910 Series Compact Control Valve - Trerice

For optimal performance, the serviceconditions (medium, flow, temperature,inlet and outlet pressures) of the application must be considered whenselecting a Valve . Please refer to the Valve Selection Section of this the Valve Selection tables for the capabilities of a particularvalve/actuator assembly. Improperapplication may cause failure of thevalve, resulting in possible personalinjury or property replacement or service parts pleasesee Accessories and Replacement Partsin the Regulators and Control valves section of the list price shown910 SeriesCompact Control ValveCONTROL VALVESD iaphragm Actuated7", 9", & 12"Actuator SizesHeavy Duty Die CastHousing1/2" 6" Valve SizesThe Trerice 910 Series PneumaticControl Valveoffers high quality at a

910 Series Compact Control Valve CONTROL VALVES Diaphragm Actuated 7", 9", & 12" Actuator Sizes Heavy Duty Die CastHousing 1/2" – 6" Valve Sizes The Trerice 910 Series Pneumatic Control Valveoffers high quality at an economical price, incorporating many features found only on more expensive units. Models are available

Tags:

  Series, Control, Compact, Valves, 190 series, 910 series compact control valve, 910 series compact control valve control

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 910 Series Compact Control Valve - Trerice

1 For optimal performance, the serviceconditions (medium, flow, temperature,inlet and outlet pressures) of the application must be considered whenselecting a Valve . Please refer to the Valve Selection Section of this the Valve Selection tables for the capabilities of a particularvalve/actuator assembly. Improperapplication may cause failure of thevalve, resulting in possible personalinjury or property replacement or service parts pleasesee Accessories and Replacement Partsin the Regulators and Control valves section of the list price shown910 SeriesCompact Control ValveCONTROL VALVESD iaphragm Actuated7", 9".

2 & 12"Actuator SizesHeavy Duty Die CastHousing1/2" 6" Valve SizesThe Trerice 910 Series PneumaticControl Valveoffers high quality at an economical price, incorporatingmany features found only on more expensive units. Models are available to provide the proper flow responserequired by the 910A, 910B & 910 Care used for On/Off Control applications, providing a quick-opening flow responsewhen used with single or double seated 910 TBis used for proportionalor PID Control applications, providinga throttling flow response when used with double seated or 3-way 910 EPA & 910 EPCis used for proportional or PID Control applications,providing an equal percentage flowresponse when used with single seated W.

3 Eight Mile Road Oak Park, MI 48237-3288 TEL:248/399-8000 FAX: 248/399-7246 NPTHOW TO ORDERS ample Order Number:910TB - A56 Actuator Model( Control Action) Valve Body Number910A 910B On/OffRefer to pages 230 234910C910 TBThrottlingRefer to pages 235 238910 EPAE qual PercentageRefer to page 239910 EPCH ousingDie cast aluminum, epoxy powdercoated blue finishSetting ScaleIntegral to housingAdjustment ScrewBrassAdjustment Screw BushingLubricant impregnated sintered bronzeRange Adjustment SpringCadmium platedPressure PlateAluminumDiaphragmNylon reinforced EDPMAir Pressure to Diaphragm30 psig maximumAir Pressure Connection1/8 NPT FemaleOperating TemperatureAmbient.

4 -40 F (-40 C) to 180 F (82 C)Process Flow:-40 F (-40 C) to 410 F (210 C)Specifications910 SeriesCompact Control ValveCONTROL VALVESAll dimensions are nominal. Dimensions in [ ] are in millimetersActuatorDiaphragmControl InputModelSizeActionSignal910A7"On/Off15 psi910B10"On/Off15 psi910C12"On/Off15 psi910TB10"Throttling*3-15 psi910 EPA7"Equal3-15 psiPercentage910 EPC12"Equal3-15 psiPercentage*Includes 3-WayActuator NumberAB Approx. Shipping Weight [178] [249] lbs [ kg] [236] [249] lbs [ kg] [290] [249] lbs [ kg] [236] [249] lbs [ kg] [178] [249] lbs [ kg] [290] [249] lbs [ kg]B1.

5 Determinethe Actuator Model (910A, 910B, 910C, 910TB,910 EPA or 910 EPC) required. Note:Refer to the maximum close-off pressure columns in the Valve Body Selection tables to determine the Actuator size required by your Determinethe Valve Size, style and material requiredby the application. Note: Consult the Valve Selection Table to determine the required Valve Body W. Eight Mile Road Oak Park, MI 48237-3288 TEL:248/399-8000 FAX: 248/399-7246