A-Series - Carling Tech

NOW PART OF. A-Series Hydraulic-Magnetic Circuit breaker P ROD UC T W E BP A GE. request sample, configure part Compact and Versatile Design The A-Series hydraulic-magnetic circuit breakers offer precise operation in a compact size for both general purpose as well as full amp load applications. Visi Rocker and recessed paddle actuators are ideally suited for clean, front panel designs while the metal toggle configuration is ideal for harsh environments. The A-Series is available as a one to six pole configuration, rated up to 50 amps, 277 VAC/80 VDC and has a max IC. of 7,500 amps. 1-6 50 277 80 7500A. Poles Amps Max VAC Max VDC Max Max IC. Typical Applications Marine Renewable Energy Welders Industrial Automation Medical Equipment Telecom Generators Military Commercial Food Tech Specs Electrical Mechanical Endurance 10,000 ON-OFF operations @ 6.

(Values Based on Series Trip Circuit Breaker) AMPERE RATING 1000 100 10 1 0.1 0.01 0.01 0.100-5.0 5.1-20.0 20.1-50.0 15% FIGURE 1 S M H O 25% 35% CURRENT (AMPS) TOLERANCE (%) 0.1 1 10 100 0.001 RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) 60 Hz 1/2 Cycle Multiple of Rated …

Tags:

  Series, Breaker, A series

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of A-Series - Carling Tech

1 NOW PART OF. A-Series Hydraulic-Magnetic Circuit breaker P ROD UC T W E BP A GE. request sample, configure part Compact and Versatile Design The A-Series hydraulic-magnetic circuit breakers offer precise operation in a compact size for both general purpose as well as full amp load applications. Visi Rocker and recessed paddle actuators are ideally suited for clean, front panel designs while the metal toggle configuration is ideal for harsh environments. The A-Series is available as a one to six pole configuration, rated up to 50 amps, 277 VAC/80 VDC and has a max IC. of 7,500 amps. 1-6 50 277 80 7500A. Poles Amps Max VAC Max VDC Max Max IC. Typical Applications Marine Renewable Energy Welders Industrial Automation Medical Equipment Telecom Generators Military Commercial Food Tech Specs Electrical Mechanical Endurance 10,000 ON-OFF operations @ 6.

2 Maximum Voltage 277 VAC 50/60 Hz, 80 VDC. per minute; with rated Current &. Current Ratings Standard current coils: , Voltage. , , , , , , Trip Free All A-Series Circuit Breakers will , , , , , , , trip on overload, even when the , Other ratings available actuator is forcibly held in the ON. - consult ordering scheme. position. Standard Voltage Coils DC-6V, 12V; AC-120V, Other ratings Trip Indication The operating actuator moves available, consult ordering positively to the OFF position scheme. when an overload causes the Auxiliary Switch Rating SPDT; A - 250 VAC, circuit breaker to trip. When A-65 A - 80 VDC, mid-trip handle is specified, the - 125 VAC (with gold contacts) handle moves to the mid position on electrical trip of the circuit Insulation Resistance Minimum: 100 Megohms at 500 breaker .

3 When mid-trip handle VDC with alarm switch is specified, the handle moves to the mid Dielectric Strength UL, CSA - 1500V 60 Hz for one position & the alarm switch minute between all electrically actuates when the circuit breaker isolated terminals. A-Series is electrically tripped rocker circuit breakers comply with the 8mm spacing & 3750V. dielectric requirements from Physical hazardous voltage to operator accessible surfaces per EN 60950 Number of Poles 1 - 6 Poles (handle) and 1-3 poles and VDE 0805. (rocker) at 30 Amps or and 2 poles at 31 Amps thru 50 Amps. Resistance, Impedance Values from Line to Load Terminal based on series Trip Circuit Internal Circuit Config. series , (with or without auxiliary breaker . switch), Shunt and Relay with RESISTANCE. RESISTANCE, PER POLEVALUES. IMPEDANCE VALUES current or voltage trip coils, Dual from from Line Line to to Load Load Terminals Terminals Coil, Switch Only with or without (Values (Values Based Based onon series series Trip Trip Circuit Circuit breaker ).)

4 breaker ). auxiliary switch. 1000. CURRENT TOLERANCE Weight Approximately 65 grams/pole. (AMPS) (%) (Approximately ounces/pole). 100. - 15 Standard Colors Housing - Black; Actuator- See 10. - 25 Ordering Scheme. - 35. O. H 1 Environmental M. S Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: 60 Hz 1/2 Cycle Inrush Pulse Tolerance Time Delay Curves Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per 42, 44 & 46. (50 Amps Max.). Rated Current Method 213, Test Condition I . Multiple of Time Delay Curves 1 10 100. 22, 24 & 26. (50 Amps Max.) Instantaneous and ultra-short curves tested @ 90% of rated AMPERE RATING. current. Pulse Tolerance Curves CURRENT TOLERANCE. (AMPS). 60 Hz 1/2 Cycle15%. (%) Time in Milliseconds Vibration Withstands excursion from Inrush Pulse Tolerance 25% 10-55 Hz, and 10 Gs 55-500 Hz, at 35%.

5 Time Delay Curves 42, 44 & 46. 50 Hz 1/2 Cycle rated current per Method 204C, FIGURE 1 Inrush Pulse Tolerance (50 Amps Max.). Test Condition A. Instantaneous Rated Current Rated Current Time Delay Curves and ultrashort curves tested at Multiple of 22x 42, 44 & 46. Multiple of (50 Amps Max.). Time Delay Curves 22, 24 & 26. (50 Amps Max.). 10x Time Delay Curves 22, 24 & 26. 90% of rated current. (50 Amps Max.). Moisture Resistance Method 106D; ten 24-hour cycles @ + 25 C to +65 C, 80-98% Time in Time in Milliseconds days @ +85 C, 85% RH. Milliseconds Salt Spray Method 101, Condition A (90-95%. 50 Hz 1/2 Cycle Inrush Pulse Tolerance RH @ 5% NaCl Solution, 96 hrs). Rated Current Time Delay Curves 22x 42, 44 & 46. Thermal Shock Method 107D, Condition A (Five Multiple of (50 Amps Max.). 10x Time Delay Curves cycles @ -55 C to +25 C to +85 C.)

6 22, 24 & 26. (50 Amps Max.) to +25 C). Operating Temperature -40 C to +85 C. 02. *Manufacturer reserves the right to change product specification without prior notice. Time in Milliseconds Tech Specs Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector. Component Supplementary Protectors Voltage Current Rating Short Circuit Capacity (Amps). Application Codes Circuit General UL / CSA. Configuration Max Full Load Notes Frequency Phase Purpose With Without Rating Amps UL CSA. Amps Backup Fuse Backup Fuse 32 DC --- - 15 --- --- 5000 TC1, OL1, U2 TC1, OL1, U2. 65 DC --- 31 - 50 --- --- 7500 TC1, 2, OL1, U1 TC1, 2, OL1, U1. - 30 --- --- 7500 TC1, 2, OL1, U1 TC1, 2, OL1, U1. 80 DC --- --- 31 - 50 --- 7500 TC1, 2, OL0, U1 TC1, 2, OL0, U1.

7 125 50 / 60 1 - 30 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Rocker 125 50 / 60 1 1 - 50 --- --- 2000 TC1, OL1, U2 TC1, OL1, U2. 125 50 / 60 14 1 - 50 --- --- 1000 TC1, OL1, U2 TC3, OL1, U3. 125 / 250 50 / 60 13 - 30 --- --- 3000 TC1, 2, OL1, U2 TC1, 2, OL1, U2 Rocker series 125 / 250 50 / 60 13 - 50 --- --- 3000 TC1, 2, OL1, U2 TC1, 2, OL1, U2 Handle - 30 --- --- 1500 TC1, 2, OL0, U2 TC1, 2, OL0, U2 Single Pole 1 - 30 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Two Pole --- --- 3000 TC1, 2, OL0, U1 TC1, 2, OL0, U1. 250 50 / 60. 14 1 - 50 --- --- 1000 TC1, OL1, U2 TC3, OL1, U3. - 30 --- 5000 2 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1. 3. 31 - 50 --- 2000 1 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1. 277 50 / 60 1 - 30 --- 5000 1 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1. 32 DC --- - 50 --- --- 5000 TC1, OL1, U2 TC1, OL1, U2.

8 65 DC --- - 50 --- --- 7500 TC1, 2, OL1, U1 TC1, 2, OL1, U1. - 30 --- --- 7500 TC1, 2, OL1, U1 TC1, 2, OL1, U1. 80 DC --- --- 31 - 50 --- 7500 TC1, 2, OL0, U1 TC1, 2, OL0, U1. - 30 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Rocker 125 50 / 60 1. 1 - 50 --- --- 2000 TC1, OL1, U2 TC1, OL1, U2. 125 50 / 60 14 - 30 --- --- 1000 TC1, OL1, U2 TC3, OL1, U3. 125 / 250 50 / 60 13 - 30 --- --- 3000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Rocker Dual Coil 125 / 250 50 / 60 13 - 50 --- --- 3000 TC1, 2, OL1, U2 TC1, 2, OL1, U2. 1 - 30 --- --- 1500 TC1, OL0, U2 TC1, OL0, U2 Single Pole 1 - 30 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Two Pole 1 --- 31 - 50 --- 3000 TC1, 2, OL0, U1 TC1, 2, OL0, U1. 250 50 / 60. 14 1 - 50 --- --- 1000 TC1, OL1, U2 TC3, OL1, U3. - 30 --- 5000 2 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1. 3.

9 31 - 50 --- 2000 1 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1. 277 50 / 60 1 - 30 --- 5000 1 --- TC1, 2, OL1, U1 TC1, 2, OL1, U1. 80 DC --- - 30 --- --- 7500 TC1, 2, OL1, U1 TC1, 2, OL1, U1. 125 / 250 50 / 60 1 - 30 --- --- 3000 TC1, 2, OL1, U1 TC1, 2, OL1, U1. Shunt 1 - 30 --- --- 3000 TC1, 2, OL1, U1 TC1, 2, OL1, U1. 250 50 / 60. 3 - 30 --- 5000 2 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1. 277 50 / 60 1 - 30 --- 5000 1 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1. 80 DC --- - 30 --- --- 7500 TC1, 2, OL1, U1 TC1, 2, OL1, U1. 125 / 250 50 / 60 13 - 30 --- --- 3000 TC1, 2, OL1, U1 TC1, 2, OL1, U1. Relay 1 - 30 --- --- 3000 TC1, 2, OL1, U1 TC1, 2, OL1, U1. 250 50 / 60. 3 - 30 --- 5000 2 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1. 277 50 / 60 1 - 30 --- 5000 1 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1. 65 DC --- - 50 --- 80 DC --- - 30 --- Switch Only 1 --- 31 - 50 not applicable 250 50 / 60.

10 3 - 50 --- 277 50 / 60 1 - 30 31 - 50. Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 2 Same as note 1, except that backup fuse is limited to 80 A maximum. 3 2 pole protector required (with one pole per power line) for: 125/250 VAC, 1 pole protector required for : 125 VAC, 1 Power System. 03. 4 Satisfies the requirements of clause of CSA STD No 100 for the use of supplementary protectors with portable generators. Tech Specs Electrical Tables Table B: Lists UL Recognized, CSA Accepted, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. Component Supplementary Protectors Voltage Current Rating Short Circuit Capacity (Amps). Application Codes UL / CSA VDE TUV.