1 ABB AG Calor Emag Medium Voltage ProductsGas-insulated switchgear Type switchgear type | Gas-insulated switchgearType Voltage switchgear Type busbar systems12 kV,..2500 A,.. kA24 kV,..2500 A,.. kA36 kV, ..2500 A, .. kA switchgear type | Gas-insulated switchgearType IAC classificationAFL kA 1sAFLR kA 1s1)Dependent on currentRated voltagekV122436 Rated current of current of tee-offswith circuit-breakerwith switch-disconnector/fuse short-circuit breaking , , ,5 Widthamm450 / 600 / 1200 1)

Gas-insulated switchgear Type ZX0.2 3 With IAC classification AFL 31.5 kA 1s AFLR 31.5 kA 1s 1) Dependent on current. Rated voltage. …

Tags:

  Product, Medium, Voltage, Medium voltage products

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ABB AG –Calor Emag Medium Voltage Products …

1 1 ABB AG Calor Emag Medium Voltage ProductsGas-insulated switchgear Type switchgear type | Gas-insulated switchgearType Voltage switchgear Type busbar systems12 kV,..2500 A,.. kA24 kV,..2500 A,.. kA36 kV, ..2500 A, .. kA switchgear type | Gas-insulated switchgearType IAC classificationAFL kA 1sAFLR kA 1s1)Dependent on currentRated voltagekV122436 Rated current of current of tee-offswith circuit-breakerwith switch-disconnector/fuse short-circuit breaking , , ,5 Widthamm450 / 600 / 1200 1)

2 Heightbmm2400 Depth cmm1330acb switchgear type | Gas-insulated switchgearType individually partitionedfor extended application range Up to 36kV rated Voltage Currents up to 2500A for busbars and incoming feeders Short-circuit currents up to kA for all Voltage levels Local manual operation of all switching devices Optionally also with remote control Suitable for any protection or control device Replacement of a panel in the row without gas work switchgear type | Gas-insulated switchgearType low Voltage compartment2 Three position disconnector operating mechanism3 Mechanism bay with operator controls4 Circuit-breaker operating mechanism5 Cable connector6 Window-type current transformer7 Bushing with outer cone8 Isolatable Voltage transformer on the cable9 Pressure relief disk10 Vacuum circuit-breaker11 Three position disconnector12 Busbars13 Plug-in busbar Voltage transformersSF612345687910111213 Circuit-breaker panel.

3 1250 A switchgear type | Gas-insulated switchgearType variant Circuit-breaker panel 630A up to 24kV switchgear type | Gas-insulated switchgearType variants Circuit-breaker panel630A / 1250A for all voltages Cable termination panel 630A / 1250A switchgear type | Gas-insulated switchgearType variants Circuit-breaker panel 2500A Cable termination panel 2500 ASimilarly for 1600A 2000A switchgear type | Gas-insulated switchgearType variants Sectionalizer / Riser 1250A Sectionalizer / Riser 2000 ASimilarly for 1600A and 2500A switchgear type | Gas-insulated switchgearType variants Switch-disconnector panel with fusesUp to 24kV switchgear type | Gas-insulated switchgearType Partitioned function compartments maximum safety Completely shockproof arrangement High Voltage section totally independent of environmental influences Maximum availability for the operator Independence of the environment makes for extremely long system life Minimum maintenance requirement Longer life than other

4 System types switchgear type | 1 Gas-insulated switchgear Type AG Calor Emag Medium Voltage Products switchgear type | Gas-insulated switchgearType Voltage switchgeartype busbar systems12 kV,..2500 A,..31,5 kA24 kV,..2500 A,..31,5 kA36 kV,..2500 A,..31,5 kA switchgear type | Gas-insulated switchgearType 1)Rated current of current of short-circuit breaking , , ,5 Rated short-circuit making currentkA808080 Insulating gasSF62)SF62)SF62)Widthamm600 / 800 3) 4)600 / 800 4)Heightbmm2100 Depthcmm1400-19005)Height of Cable fixing pointmm12501)Higher values as per international standards on request2)Insulating gas.

5 Sulphur hexafluoride (SF6) 3)Double feeder panel up to 25 kA, 2 x 630 A4)Rated feeder current above 1250 A5)Depending on quantity of cables per phasewith a 500mm deep LVcompartmentacbWith IAC classificationAFLR kA 1sAFL kA 1s switchgear type | Gas-insulated switchgearType sensor2 Circuit-breaker operating mechanism3 Multifunction Protection and Switchgear Control unit4 Three position disconnector operating mechanism5 Three position disconnector6 Busbar7 Pressure relief disk8 Pressure relief duct (optional)9 Ring type current transformer10 Cable plug11 Cable socket12 Measuring sockets for capacitive Voltage indicator system13 Test socket14 Circuit-breakerSF6 Feeder 1250 A switchgear type | Gas-insulated switchgearType Control Unit Modern solution of a conventional switchgear control in ZX Integral control.

6 Indication and annunciation unit Conventional control without active components Control via conventional push-buttons and key operated local / remote switch Operation of a switchgear panel without multi-functional protection-and control-unit switchgear type | Gas-insulated switchgearType meteringSingle lines of switchgear variants (SBB)Cable connection switchgear type | Gas-insulated switchgearType Voltage transformer2 Disconnecting device for Voltage transformers3 Density sensor4 Circuit-breaker operating mechanism5 Multifunction Protection and Switchgear Control unit6 Three position disconnector operating mechanism7 Three position disconnector8 Busbar9 Pressure relief disk10 Pressure relief duct12 Cable socket13 Measuring sockets for capacitive Voltage indicator system14 Test socket15 Circuit-breaker16 Combined current and Voltage sensoror

7 Current transformer17 Plasma diverterSF6 Feeder 2000 A23456789191716151413121110 switchgear type | Gas-insulated switchgearType sensor (temperature-compensated) 2 Multifunction Protection and Switchgear Control unit 3 Circuit-breaker operating mechanism4 Circuit-breake5 Three position disconnector6 Three position disconnector operating mechanism7 Busbars8 Pressure relief disk9 Pressure relief duct10 Current transformer or Rogowski coil11 Inner cone cable plug12 Inner cone cable bushing13 Measuring sockets for capacitive Voltage indicator system 14 Test socket15 Plasma diverterSF6 Double feeder panel up to 24 kV630 A for each feeder26731452891011121314158 switchgear type

8 | Gas-insulated switchgearType sectionalizer 2000 Awith option Integrated Voltage metering switchgear type | Gas-insulated switchgearType riser 2000 Awith option Integrated Voltage metering switchgear type | Gas-insulated switchgearType componentsDummy plugTest plugSurge arrestorVoltage transformerBB plug-in systemCable plug switchgear type | Gas-insulated switchgearType Partitioned function compartments maximum safety Completely shockproof enclosures High Voltage section totally independent of environmental influences No effect of site altitude on dielectric strength Maximum availability for the operator Independence of the environment makes for extremely long system life Minimum maintenance requirement Longer life than other system types switchgear type |