ABS submersible sewage pump AFP 0831-2046

ABS submersible sewage pump AFP 0831-2046 Text var Type testedand monitoredRobust, reliable submersible pumps from to 30 kW for pump-ing wastewater and sewage from buildings and sites in private, commercial, industrial and municipal areas in accordance with EN 12050-1. Available as standard AFP or as higher specification AFP(K).ApplicationsAFP submersible pumps have been designed for the economic and reliable pumping of clear or wastewater, gaseous liquids, and for sewage and sludge, in fixed or portable applications.* For fixed, wet well applications the AFP is pedestal mounted.

ABS submersible sewage pump AFP 0831-2046 Type tested Text var and monitored Robust, reliable submersible pumps from 1.3 to 30 kW for pump-ing wastewater and sewage from buildings and sites in private, commercial, industrial and municipal areas in accordance with EN 12050-1. Available as standard AFP or as higher specification AFP(K). Applications

Tags:

  Pumps, 3108, Submersible, Sewage, Abs submersible sewage pump afp 0831

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ABS submersible sewage pump AFP 0831-2046

1 ABS submersible sewage pump AFP 0831-2046 Text var Type testedand monitoredRobust, reliable submersible pumps from to 30 kW for pump-ing wastewater and sewage from buildings and sites in private, commercial, industrial and municipal areas in accordance with EN 12050-1. Available as standard AFP or as higher specification AFP(K).ApplicationsAFP submersible pumps have been designed for the economic and reliable pumping of clear or wastewater, gaseous liquids, and for sewage and sludge, in fixed or portable applications.* For fixed, wet well applications the AFP is pedestal mounted.

2 Us-ing a self-sealing coupling system the pump seals automatically on the pedestal when lowered by guide rail into position.* Dry well applications have the option of horizontal or vertical installation.* With vortex hydraulics the AFP is particularly suitable for sew-age, abrasive matter, and fluids containing stringy materials that tend to rope .* The Contrablock hydraulic system offers higher efficiency and is suitable for larger proportions of solid or fibrous water-pressure-tight, encapsulated, fully flood-proof motor and the pump section form a compact, robust, modular construc-tion.

3 Maximum allowable temperature of the medium for con-tinuous operation is 40 C (information on applications at other temperatures available on request).Available in explosion-proof versions in accordance with interna-tional standards EExd II BT4, FM and : Free-circulation cooling by the (K): Closed loop cooling system with circulation of glycol and water which has no contact with the sewage being pumped. This optimises heat exchange and avoids the danger of blockage of the cooling system with sewage installation is possible without cooling system, for intermittent use only and subject to strict stainless steel motor shaft is supported in lubricated-for-life ball sealingBetween the motor and hydraulic section is by means of a high quality, silicon carbide, double mechanical seal.

4 Standard AFP has a single mechanical seal and upper lip seal. AFP(K) has the option of double mechanical seals or a seal cartridge. The seal cartridge combines both mechanical seals into a complete, easy-to-replace unit (not available with ME motor). All seals are independent of rotation direction and resistant to temperature 80, 100, 150 and 200 DIN monitoringTCS (Thermo-Control-System) with thermal sensors in the stator to switch off the pump in the case of overheating and switch on automatically after cooling monitoringDI system consisting of a sensor in the motor and oil chambers which signals an inspection alert if there is leakage at the shaft seals (not in oil chamber on Ex version).

5 HydraulicsAFP 0831-0835, 1031-1035, 1533: vortex, open, recessed, four-vane 0841-0844, 1041-1049, 1541, 1543 & 2045: Contrablock, open single-vane 1546 & 2046: Contrablock, open double-vane * High-efficiency hydraulic design using Contrablock or vortex impellers.* Available as standard AFP or higher specification AFP(K).* AFP(K) has class H insulation and double mechanical seals as standard, with options of seal cartridge and closed loop cooling system.* Automatic seal and temperature monitoring.* Available as explosion-proof.* Designed for fixed or transportable installation.

6 * For lifting, AFP has cast eyelet, AFP(K) has stainless steel lifting , 400 V, 50 Hz, squirrel-cage motor as 2-pole (2900 r/min), 4-pole (1450) and 6-pole (980). Protection type IP 68, with stator insulation Class F (155 C) for standard AFP or Class H (180 C) for AFP(K) starting up to 3 kW; from 4 kW star-delta or direct starting is possible. Motors with other operating voltages and frequencies are also Code: AFP ME 250/2 Hydraulics:AFP .. Product range10 .. Discharge outlet DN (cm) 35 .. Hydraulic number .3 .. ImpellerMotor:ME .. M = modular motor; E = high efficiency250.

7 Motor power P2 kW x 102 .. Number of polesMaterialsDescriptionMaterialMotor housingCast iron EN-GJL-250 Motor shaftStainless steel (AISI 420)VoluteCast iron EN-GJL-250 ImpellerCast iron EN-GJL-250 Bottom plateCast iron EN-GJL-250 FastenersStainless steel (AISI 316)AFP(K) options: stainless steel motor shaft (AISI 316), stainless steel impeller (AISI 329), viton seals, and surface hardened cast iron impeller and is available in SX version as a complete stainless steel pump (see separate literature).* P1 = power at mains; P2 = power at motor shaft** Neoprene cable:(a) (b) (c) (d) 4G4 + (e) ( + for version with klixon)AFPI mpellersizeSolidsize(mm)Ratedvoltage (V) Motor power * (kW) P1 P2 Rated current (A)Speed(r/min)StartingCabletype **Weight** (kg)0831 M 15/4 M 22/4 M 30/4 S 22/43, 4, 5, 6, 7212, 3 80 80 80 80400 3~400 3~400 3~400 3~ 1450 1450 1450 1450 DOLDOLDOLDOL (a) (a) (a) (e)

8 78/90 79/90 80/92 45 M 70/2 M 40/21, 2, 34 80 80400 3~400 3~ 2900 2900Y Y (b) (b)105/121 81/930834 M 110/21, 2, 3, 4 80400 3~ 2900Y (b) 95/1030835 M 55/2 M 70/2 M 110/2651, 2, 3, 4 65 65 65400 3~400 3~400 3~ 2900 2900 2900Y Y Y (b) (b) (b)117/130117/130129/1420841 M 15/4 M 30/4 S 22/4 S 13/41, 2, 3, 4A12, 3, 4 80 80 80 80400 3~400 3~400 3~400 3~ 1450 1450 1450 1450 DOLDOLDOLDOL (a) (a) (e) (e) 78/90 80/92 56 41 M 40/21 50400 3~ 2900Y (b) 81/930844 M 110/2 M 70/212 45 45400 3~400 3~ 2900 2900Y Y (b) (b)

9 110/120100/1101031 M 30/4 M 22/4 M 15/4123, 5, 6, 7 100 100 100400 3~400 3~400 3~ 1450 1450 1450 DOLDOLDOL (a) (a) (a) 80/92 78/90 78/901032 M 90/4 M 60/4 M 40/4A12, 3, 4 100 100 100400 3~400 3~400 3~ 1450 1450 1450Y Y Y (b) (b) (b)120/136110/126107/1231033 ME 185/4 ME 160/4 ME 110/412, 34 100 100 100400 3~400 3~400 3~ 1450 1450 1450Y Y Y (c) (c) (b)290/320285/315280/3101034 ME 250/2 ME 200/2 ME 185/2 ME 150/21, 2, 3, 4, 5, 61, 2, 3, 4, 5, 678 75 75 75 75400 3~400 3~400 3~400 3~ 2900 2900 2900 2900Y Y Y Y (d) (c) (c) (c)240/270230/260225/255220/2501035 ME 150/2 ME 200/2 ME 250/26, 751, 2, 3, 4 64 64 64400 3~400 3~400 3~ 2900 2900 2900Y Y Y (c) (c) (d)

10 222/250227/255232/2601041 M 30/4 M 22/4 M 15/41,234 90 90 90400 3~400 3~400 3~ 1450 1450 1450 DOLDOLDOL (a) (a) (a) 80/92 78/90 78/901042 M 90/4 M 60/4 M 40/4A1, 23 100 100 100400 3~400 3~400 3~ 1450 1450 1450Y Y Y (b) (b) (b)117/133110/126107/1231043 M 70/21 55400 3~ 2900Y (b)105/1211045 ME 220/4 ME 185/4 ME 160/4 ME 140/4 ME 110/4A12, 2B2B3 100 100 100 100 100400 3~400 3~400 3~400 3~400 3~ 1450 1450 1450 1450 1450Y Y Y Y Y (d) (c) (c) (b) (b)300/320290/320285/315285/315280/31010 48 ME 250/2 ME 185/2 ME 150/2123 50 50 50400 3~400 3~400 3~ 2900 2900 2900Y Y Y (d) (c) (c)