Transcription of Accessories - Cooper Industries
1 Accessories Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Accessories118 Meter Mounting EquipmentCovers & Sealing Rings .. 119AW & H-Base Hubs .. 119 Flush Trim Kits & Overhead Conversion Kits .. 120 Lug-Stud & Lug-Lug Terminal Pad Assemblies .. 121 Terminal Landing Pads, 5th Jaw Terminal Kits, Insulator .. 121 Breaker Stab Assembly, Jumper Link, MTB Cover Kit .. 122 Test Blocks for TB Sockets .. 122 Class T Replacement Fuses for MTBP & MTBPL Units .. 122 Sealing Device Packages & Oil-Tight Hole Seals .. 123 Ground Lug Kits, Triplex Ground Connectors, Touch-Up Paint .. 124 Accessories Data subject to change without notice. Consult local utility for area acceptance.
2 All dimensions are in inches. AccessoriesMeter Mounting Equipment11925016A25016B (shown)2516226016 DInterchangeable gasketless hubs for conduit sizes 1"through 21 2" per ANSI All hubs are threaded andsecured by bolting hub to top of meter enclosure withtapped holes in gasketless hubs for conduit sizes 2" through4" per ANSI All hubs are threaded and secured bybolting hub to top of meter enclosure with tapped holes Description Number 30420 Steel Cover For Socket Opening25162 Clear Lexan Cover For Socket Opening25016A Aluminum Snap Type Sealing Ring25016B Stainless Steel Snap Type Sealing Ring25016D
3 Anodized Aluminum Screw Type Sealing RingCatalog Hub Description Number AW CAP CapAW100 1 Conduit SizeAW125 11/4 Conduit SizeAW150 11/2 Conduit SizeAW200 2 Conduit SizeAW250 21/2 Conduit SizeCatalog Hub Description Number H7 Adapter From Large H-Base Hub To AW HubH10 Closure PlateH20 2 Conduit SizeH25 21/2 Conduit SizeH30 3 Conduit SizeH35 31/2 Conduit SizeH40 4 Conduit SizeCovers & Sealing RingsAW HubsH-Base HubsAW200AW CAPH7H10 Accessories Data subject to change without notice.
4 Consult local utility for area acceptance. All dimensions are in inches. Accessories120 Meter Mounting EquipmentFlush trim kits are used to change a meter enclosure from a surface mount to a include all necessary hardware and instructions for field conversion kits are used on the U404 series to convertmeter enclosure from underground to overhead feed. Kit isconstructed with knockouts, an H-base hub provision and sealableutility cover. The kit includes (3) mechanical lugs to convert lineside stud termination to mechanical termination: stud spacing 13 4" center to range per lug: (1) 4 AWG 600 kcmil or (2) 1 AWG 250 kcmil or (2) 2 AWG 3/0 AWGC atalog Size (Height x Width x Depth)
5 Number CK8326 32 x 8 x 6 Catalog Fits Enclosures Number FK1432 14 x 32FK2432 24 x 32FK2438 24 x 38FK3038 30 x 38FK3447 34 x 47FK1421A 14 x 211/2FK1430 14 x 30FK2421A 24 x 211/2FK2430A 24 x 30FK3221A 32 x 21FK3230 32 x 30FK2832A 28 x 321/2 Overhead Conversion KitFlush Trim KitsAccessories Data subject to change without notice.
6 Consult local utility for area acceptance. All dimensions are in inches. AccessoriesMeter Mounting Equipment121251049005E shownCatalog Description Number 25104 Insulator - Red Poly-Glass 13/8 H x 13/8 D, 3/8 ThreadCatalog Description Number 50371 100 Amp & 200 AMP, 1 , 3W Applications50365 100 Amp & 200 AMP, 1 , 3W ApplicationsEach pad comes complete with insulator.
7 Catalog Max Amperes Max Incoming/Outgoing Number Conductors9005B 200 Amp (1) 250 kcmil9005BB 200 Amp (1) 250 kcmil9005C 400 Amp (1) 600 kcmil or (2) 250 kcmil9005D 600 Amp (2) 600 kcmil or (4) 250 kcmil9005E 800 Amp (3) 600 kcmil or (6) 250 kcmil9005F 1200 Amp (4) 600 kcmil or (8) 250 kcmilR-9002_ SeriesR-9002 EEshownR-9002 EELshownCatalog Max Amperes Phase & Neutral Conductor Number Line LoadR9002C 400 Amp 2 Studs / (1) 4 AWG- 600 kcmil or (2) 1/0 - 250 kcmilR9002CC 400 Amp 2 Studs / (1) 4 AWG- 600 kcmil or (2) 1/0 - 250 kcmilR9002E 800 Amp 4 Studs / (3) 4 AWG- 600 kcmil or (6) 1/0 - 250 kcmilR9002EE 800 Amp 4 Studs / (3) 4 AWG- 600 kcmil or (6)
8 1/0 - 250 kcmilR9002F 1200 Amp 6 Studs / (4) 4 AWG- 600 kcmil or (8) 1/0 - 250 kcmilR9002FF 1200 Amp 6 Studs / (4) 4 AWG- 600 kcmil or (8) 1/0 - 250 kcmilEach pad comes complete with insulator. Each pad comes complete with insulator. Catalog Max Amperes Phase & Neutral Conductor Number Line / LoadR9002CL 400 Amp (1) 4 AWG- 600 kcmil or (2) 1/0 - 250 kcmilR9002 CCL 400 Amp (1) 4 AWG- 600 kcmil or (2) 1/0 - 250 kcmilR9002EL 800 Amp (3) 4 AWG- 600 kcmil or (6) 1/0 - 250 kcmilR9002 EEL 800 Amp (3) 4 AWG- 600 kcmil or (6) 1/0 - 250 kcmilR9002FL 1200 Amp (4) 4 AWG- 600 kcmil or (8) 1/0 - 250 kcmilR9002 FFL 1200 Amp (4) 4 AWG- 600 kcmil or (8)
9 1/0 - 250 kcmilR-9002_L Series9005_ SeriesLug - Lug Terminal Pad Assemblies *UL ListedTerminal Landing Pads *Not UL Listed5th Jaw Terminal KitsMiscellaneousLug - Stud Terminal Pad Assemblies *UL Listed5037150365 Accessories Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Accessories122 Meter Mounting Equipment20213A20212 ASJ-1002543920252 ACatalog Description Number 20212A 2-Pole20213A 3-PoleSJ-100 100 & 200 Ampere Jumper Link25439 Cover Kit For MTB UnitsCatalog Description Number
10 20252A 100 Amp, 2-Pole Test Block20250C 100 Amp, 2-Pole Test Block With Barriers20252B 200 Amp, 2-Pole Test Block20251C 200 Amp, 2-Pole Test Block With Barriers20258A 100 Amp, 2-Pole With Lugs On Both Ends20258B 200 Amp, 2-Pole With Lugs On Both EndsCatalog Description Number 25339A 100 Amp, 300 Volt25339B 200 Amp, 300 Volt25339C 100 Amp, 600 Volt25339D 200 Amp.