Example: dental hygienist

ACS 2000, 4kV – 6.9kV 300-2000 HP - …

Medium voltage AC driveACS 2000, 4kV HPProduct brochureProudly Distributed by Gross Automation | (877) 268-3700 | ACS 2000 brochure | ABBP roudly Distributed by Gross Automation | (877) 268-3700 | | ACS 2000 brochure 3 ACS 2000 simple and reliable motor controlThe ACS 2000 medium voltage AC drive provides reliable motor control for a wide range of ACS 2000 is designed for high reliability, easy installation and fast commissioning, reducing the total cost of ownership. With the integration of an Active Front End (AFE) combined with multilevel control, the ACS 2000 is an Ultra Low Harmonic (ULH) design that minimizes line side harmonics.

6 ACS 2000 brochure | ABB ACS 2000 The air-cooled general purpose drive provides simple and reliable motor control for a wide range of applications.

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ACS 2000, 4kV – 6.9kV 300-2000 HP - …

1 Medium voltage AC driveACS 2000, 4kV HPProduct brochureProudly Distributed by Gross Automation | (877) 268-3700 | ACS 2000 brochure | ABBP roudly Distributed by Gross Automation | (877) 268-3700 | | ACS 2000 brochure 3 ACS 2000 simple and reliable motor controlThe ACS 2000 medium voltage AC drive provides reliable motor control for a wide range of ACS 2000 is designed for high reliability, easy installation and fast commissioning, reducing the total cost of ownership. With the integration of an Active Front End (AFE) combined with multilevel control, the ACS 2000 is an Ultra Low Harmonic (ULH) design that minimizes line side harmonics.

2 This technology eliminates expensive, specialized transformers, while offering the added benefit of a smaller overall package. With its compact packaging, the ACS 2000 can be retrofitted to control standard induction motors via a direct connection to the line supply (direct-to-line). Alternatively, a simple two-winding input isolation transformer can be applied to allow for connection to various line side supply ACS 2000 direct-to-line configuration combines the cost savings of a transformerless variable speed drive system with the benefits of Voltage Source Inverters (VSIs), including excellent availability and reliability, high and constant power factor and superior dynamic control performance.

3 The heritage of ABB s VSI topology, along with a patented HV-IGBT-based multi-level control, provides a proven track record for reliable and motor friendly medium voltage AC drive product features Suitable for use with or without an input isolation transformer Meets IEEE 519 and IEC 61000-2-4 Direct-to-line configuration (transformerless) allows 3 in and 3 out power cabling for quick and easy installation Multi-level switching topology and built-in dv/dt filtering enables use with new or existing induction motors Regenerative option and ability to maintain near unity power factor across the entire speed range provides additional energy savings Modular construction provides high reliability and low maintenance costsFields of applicationIndustriesApplicationsWaterPu mps, blowersHVACC hillers, pumps, fansPower generationFans, pumps, conveyors and coal millsCement, mining and mineralsConveyors, crushers, mills, fans and pumpsChemical, oil and gasPumps, compressors.

4 Extruders, mixers and blowersMetalsFans and pumpsPulp and paperFans, pumps, refiners, vacuum pumps and chippersOther applicationsTest standsProudly Distributed by Gross Automation | (877) 268-3700 | ACS 2000 brochure | ABBKey featuresThe ACS 2000 general purpose drive offers unique features which provide superior application flexibility with a standard ; of the ACS 2000 with direct-to-line connectionLine supply connection flexibilityDepending on the user preference or the existing installation, the ACS 2000 is available for connection to an external input isolation transformer or for use without a transformer, the latter allowing a direct connection to the industrial line supply (direct-to-line).

5 Direct-to-line connectionThe ACS 2000 direct-to-line configuration can lower investment costs substantially. Due to its compact size and lighter weight compared to a drive requiring a transformer, it also results in lower transportation costs and requires less space in the electrical ACS 2000 can be easily retrofitted to existing motors while the direct-to-line technology results in quick and easy installation and disconnectABB can also offer a configurable disconnect option package for a flexible, self contained switchgear solution where no control coordination is required upstream. It provides a visible blade switch disconnect and integral input contactor with options such as as motor protection relay, control power transformer and other customer ; isolatorTopology of the ACS 2000 with direct-to-line connection with configurable disconnectProudly Distributed by Gross Automation | (877) 268-3700 | | ACS 2000 brochure 5 Active Front End for network friendly and energy efficient operation The ACS 2000 is equipped with an Active Front End (AFE) which can be used in conjunction with a simple input isolation transformer or for direct connection to the line supply.

6 It provides low harmonics and enables optional regenerative capability for increased energy Low Harmonic Design The AFE provides an ultra low harmonic (ULH) footprint which meets the most stringent requirements for harmonic distortion as defined by IEEE 519 and IEC 61000-2-4. This avoids the need for harmonic analysis or the installation of additional harmonic energy consumption For applications with high braking energy, the ACS 2000 is available with optional Regeneration capability, which feeds back braking energy to the line supply and reduces overall energy currentLine voltage50 Hz operation pointAmpsVolts-15000-10000-5000050001000 015000 VoltsLine and motor current and voltage at 6kV operationPowerful performance with DTC Precise and reliable process control, together with low energy consumption, results in high performance.

7 The ACS 2000 control platform uses ABB s award-winning Direct Torque Control (DTC), resulting in the highest torque and speed performance as well as the lowest losses ever achieved in medium voltage AC drives. Control of the drive is immediate and smooth under all conditions. Motor friendly output waveform for use with new or existing motors The ACS 2000 provides near sinusoidal current and voltage waveform making it compatible for use with existing motors. This is achieved with ABB s patented multilevel topology which utilizes one DC link enabling a multi-level output waveform with a minimum number of power currentMotor voltage50 Hz operation pointAmpsVolts-15000-10000-5000050001000 015000 VoltsVoltsVoltsProudly Distributed by Gross Automation | (877)

8 268-3700 | ACS 2000 brochure | ABBACS 2000 The air-cooled general purpose drive provides simple and reliable motor control for a wide range of 2000, 1000 hp, 4 kVFrame 1 User-friendly drive control panel for local operation Keypad with multi-language display Main supply on/off pushbuttons Emergency off pushbuttonDC bus grounding switch for safetyElectromechanically interlocked doors for safetyInput reactor with common mode filter for direct-to-line connectionProudly Distributed by Gross Automation | (877) 268-3700 | | ACS 2000 brochure 7 Designed for easy installation, fast commissioning and efficient maintenance reducing the total cost of unit (INU)Active Front End (AFE)Cable connection section allows top and bottom entryControl sectionWithdrawable phase modulesACS 2000, 2000 hp, 4 kVFrame 2 Redundant fan (optional)Proudly Distributed by Gross Automation | (877) 268-3700 | ACS 2000 brochure | ABBF eatures and benefitsFeaturesAdvantagesBenefitsOperat ion without transformer (direct-to-line)

9 No transformer requiredReduces capital expenditure, light weight, compactEasy retrofit to existing motorsMinimizes investmentEasy and fast commissioningReduces overall cost of projectCompact and light drive systemLowers transportation costs; less space required in electrical roomActive Front End (AFE)Ultra low harmonic (ULH) footprintHarmonic emissions compliant with all relevant standardsAllows operation with an input isolation transformer or for direct connection to the line supplyFlexibility of installationEnergy savingsMaintains near unity power factor across the entire speed rangeReduces energy loss in distribution system, avoiding utility penalties and the need for larger cablesRegenerative braking optionMinimizes energy consumptionMultilevel topologyPatented multilevel topologyLow parts count boosts drive availabilityProvides near sinusoidal current and voltage waveformsCompatible with new or existing motorsVoltage Source Inverter (VSI)

10 TopologyExcellent availability, reliability and efficiencyHigher uptime of plant or processHigh and constant power factorEliminates utility penaltiesSuperior dynamic control performanceSafe ride through during supply voltage dips and better process controlDirect Torque Control (DTC)Precise and reliable process control with superior performanceHigher productivityCompact sizeRequires less space in electrical roomFrees up valuable floorspaceProudly Distributed by Gross Automation | (877) 268-3700 | | ACS 2000 brochure 9 Simple drive system integrationInstalling a medium voltage AC drive could not be easier with ABB s ACS 2000 ultra low harmonic with its flexible line supply connection options and advanced software tools the ACS 2000 allows smooth and simple drive system integration into any industrial control interfaceABB offers an open communication strategy, enabling connection to higher-level process controllers.