A UTC Fire & Security CompanyEffective: October 2007K-84-11 Addressable Manual pull StationSeries 3300 FEATURES Exclusive KIDDE Design Unique Field Labeling for either Fire Alarm or Suppression Applications Dual Action Operation Interfaces directly to Kidde Addressable Control Panel SLC Communication Loop FM Approved cULus Listed for US and Canada Other domestic approvals in process Surface and Weatherproof Backboxes Flashing LED Keylock for ResetDESCRIPTIONThe Kidde Addressable Manual pull Stations is an intel-ligent initiating device that contains its

A UTC Fire & Security Company Effective: October 2007 K-84-11 Addressable Manual Pull Station Series 3300 FEATURES • Exclusive KIDDE® Design • Unique Field Labeling for either Fire Alarm or

Tags:

  Manual, Series, Station, Addressable, Pull, Addressable manual pull station series

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Addressable Manual Pull Station Series 3300 A …

1 A UTC Fire & Security CompanyEffective: October 2007K-84-11 Addressable Manual pull StationSeries 3300 FEATURES Exclusive KIDDE Design Unique Field Labeling for either Fire Alarm or Suppression Applications Dual Action Operation Interfaces directly to Kidde Addressable Control Panel SLC Communication Loop FM Approved cULus Listed for US and Canada Other domestic approvals in process Surface and Weatherproof Backboxes Flashing LED Keylock for ResetDESCRIPTIONThe Kidde Addressable Manual pull Stations is an intel-ligent initiating device that contains its

2 Own SmartOne Addressable Input (AI) module and interfaces directly tothe Kidde PEGAsys and ARIES control panels. Theinitiating device circuit is wired as NFPA Class B. The Manual pull Station is constructed of heavy die-castaluminum for long life and uses an internal toggle switchfor reliable to othe SmartOne devices, the unit is field pro-grammable using the control panel keypad or Hand-HeldProgrammer. The owner location message and reportingtype can be customized by the use of a programming util-ity utilized with the control panel.

3 A status LED ismounted on the unit and indicates the status by a 2 or 9second flash interval. A Trouble condition inhibits the sta-tus LED the pull Station is designed for quick, efficientemergency response, its double action PUSH/ pull levers prevent accidental pull Station can be mounted in an indoor or outdoorweatherproof backbox (Model SBG-32S or Model SGB-32C) or a North American 2-1/2 in. (64 mm) deep single-gang box. The Station terminal block on the AI module accepts 14,16 and 18 AWG ( mm2, mm2, and mm2) #18 is the minimum ALARM OR SUPPRESSION RELEASE LABELINGThe pull Station has a unique labeling method which pro-vides the installer the greatest amount of flexibility with-out the expense of having to carry extra inventory.

4 Sevenheavy-duty Lexan self-adhesive labels are shipped witheach Station : FIRE ALARM FM-200 RELEASE CO2 RELEASE FE-13 RELEASE FIRE SYSTEMS RELEASE HALON-1301 RELEASE NOVEC 1230 RELEASEA UTC Fire & Security Company400 Main StreetAshland, MA 01721Ph: : literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product s suitability for a particular application. The prod-uct must be properly applied to work you need more information on this product, or if you have a particular problem or ques-tion, contact KIDDE-FENWAL, INC.

5 , Ashland, MA 01721. Telephone: (508) Rev AA 2007 Kidde-Fenwal in USA SPECIFICATIONSSGB-32S INTERIOR SURFACE BACKBOXSGB-32C WEATHERPROOF SURFACEBACKBOXORDERING INFORMATIONDIMENSIONS(shown with Fire System Release Label installed) Station Type:Double Action, with integral Smart-One Addressable ModuleInitiating Device Circuit:EOL Resistor Value:Max. CircuitResistance:Max. CircuitCapacitance:Style B (Class B) Wiring10 K Ohm (06-129025-003)50 Ohm (25 ohm per conductor) FOperating Tempera-ture Range:-40 F to 150 F (-40 C to 66 C)Operating Humidity Range:0-95% RHConstruction:Die-cast metal housingCompatible Electrical Boxes:Indoor: Sheet metal Model SGB-32 SOutdoor: Weatherproof Die-cast Model SGB-32 CShipping lbs.

6 (510 g)Dimensions:4-3/4 in. H x 3-1/4 in. W x 2-1/4 in. DConstruction:Steel sheet :Two knockouts for 1/2 in. conduit connectors, one on top and :Mounts to the box with (4) 8/32 screws, which ship with each :4-3/4 in. H x 3-1/4 in. W x 2-1/4 :Cast :One threaded opening for 1/2 in. conduit :Mounts to the box with (4) 8/32 screws and a foam gasket, which ship with each NumberDescription84-330002-001 Addressable , Double Action Manual pull Station ships with mounting hard-ware, 2 keys, 1 break rod, and label Input Module (Normally Open Devices)84-100009-001 SGB-32S Indoor Backbox84-100009-002 SGB-32C Outdoor Waterproof Backbox06-129025-00310 K Ohm Resistor84-100008-002 Pkg.

7 Of (12) Breakrods 06-118013-001 Spare Key06-231866-930 Label Set3-1/4 in.(83 mm)1-5/64 in.(27 mm)4-3/4 in.(121 mm)31/32 in.(24 mm)2-1/4 in. MAX.(57 mm)PUSHPULLFIRESYSTEMRELEASEFIRESYSTEMRE LEASEK idde is a registered trademark of Kidde-Fenwal, is a trademark of Kidde-Fenwal, is a registered trademark of the Greak Lakes Chemical and Novec are trademarks of is a trademark of is a registered trademark of the General Electric Company.