Example: tourism industry

Advanced Alkaline Electrolysis - Energy

Advanced Alkaline ElectrolysisRichard Bourgeois, Global Research CenterNiskayuna, NYThis presentation does not contain any proprietary or confidential informationProject #PDP162 AcknowledgementsAcknowledgment: This material is based upon work supported by the Department of Energy under Award Number DE-FC-0706-ID14789 Disclaimer: This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights.

Distributed Industrial (250kWe – 1MWe) Sources: Chemical Economics Handbook (SRI, 2004) 1 US Census (2002) 10 100 1000 10000 100000 1000000 0 50 100 150 200 250 300 350 Number of Sites (US) Site Capacity, kg H2/day Ammonia Production Petroleum Float Refining Glass Food Hydrogenation Electronics Metals BWR Water Chemistry Generator Cooling ...

Tags:

  Distributed

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Advanced Alkaline Electrolysis - Energy

1 Advanced Alkaline ElectrolysisRichard Bourgeois, Global Research CenterNiskayuna, NYThis presentation does not contain any proprietary or confidential informationProject #PDP162 AcknowledgementsAcknowledgment: This material is based upon work supported by the Department of Energy under Award Number DE-FC-0706-ID14789 Disclaimer: This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights.

2 Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency : 30 September 2006 End: 30 December 200820% completeBudgetTotal Funding: $1,239,479 DOE Share:$ 973,783 Contractor:$ 265,696funded by both the DOE Nuclear Hydrogen Initiative and DOE HFCIT programs Received in 2006: $542,5462007 Funding (to date) : $ 92,478 Barriers AddressedG.

3 Capital Cost of Electrolysis SystemsI. Grid Electricity EmissionsPartnersGE Global ResearchGE Energy NuclearEntergy NuclearNational Renewable Energy Laboratory4 ObjectivesStudy the feasibility of using Alkaline Electrolysis technology with current-generation nuclear power for large scale hydrogen production:Economic Feasibility :Market study of existing industrial H2 usersTechnical Feasibility :Developing pressurized low cost electrolyzerCodes and Safety:Environmental and regulatory impact assessmentUnitsDOE 2012 TargetCell Efficiency%69% ( )System Cost$/kg H2$ ($400/kW)Electricity Cost$/kg H2$ Cost$/kg H2$ 1.

4 Define market and requirements Industrial users survey Technical and pricing requirements Nuclear regulatory and environmental impact issuesTask 2: Design and build pressurized electrolyzer stack Develop plastic stack technology Low cost electrode methodsTask 3: Plastics oxidation lifing Creep resistance Oxidation Task 4: Demonstrate electrolyzer performance and capital costsTask 5: System operation testing O&M cost assessmentTask 6: Create industrial-scale system conceptual designTask 7: Create 1-kg-per-second demonstration system conceptual design80% complete10% complete5% complete6 $ 1 BSize:Growth: $ B 10 % CAGR $ 17 B % CAGR >$ B 5% CAGR Flat Demand Key Use.

5 Fertilizer Captive H2 Production Facilities CAGR 5% CAGR >$ BCaptive (90%)Merchant (10%) Hydrogen Used to Remove Sulfur EU & US Regulations Mandating Lower Sulfur Content in Gas, Diesel Captive H2 Production Facilities Hydrogen Used for High Heat Processes Plasma Spray Batch type process Manufacture of Specialty Chemicals for a Variety of Industries Methanol Hydrogenating Oils for a range of applications:Source: HSBC, 2004 RefineriesAmmonia ProductionMetals Fab. &TreatmentChemical Mfr gFood &Personal CareGlobal Hydrogen Market7 Industrial market infrastructure can lead fueling infrastructureDistributed Industrial (250kWe 1 MWe)Sources.

6 Chemical Economics Handbook (SRI, 2004) US Census (2002)1101001000100001000001000000050100 150200250300350 Number of Sites (US)Site Capacity, kg H2/dayAmmonia ProductionPetroleum RefiningFloat GlassFoodHydrogenationElectronicsMetalsB WR Water ChemistryGeneratorCoolingLarge-Scale Commercial (200 MWe Electrolysis )Industrial Hydrogen Market Segments8$446$5,000 Production$1,426$16,000 PrototypePer Nm3/hPer kg/hProjected CapEx, 5 kg/hr stack :$446 Production$1,426 PrototypePer Nm3/hrPer kg/hrGE Technology Capital CostsAt 50 kWh/kg H2, production stack cost is $100/kW9$ $ $ $ $ $ $ $ $ $ $ Cost, Cents / kWh56 Hydrogen Cost per kgFeedstockO&MBOP CapitalStack Capital$ $ $ $ $ $ $ $ $ $ $ CapitalStack CapitalSource: GE Global Research, NREL H2A ModelProjected H2 Cost with GE Electrolyzer:1000 kg/day, 30 bar pressureLow-cost electricity still key to meeting targets.

7 *electricity, water*DOE Target $3/kg10existing fleet - US /kWh (2005)Source: NEI, 2006 Electricity Production CostsLowest costelectricity available from existing nuclearElectricity market demands set actual price11GE Alkaline Electrolysis Technology110100base metalsGE el ec t r o depositedGE sp r a yprecious metalsCell OverpotentialRelative Cost per Unit AreaTa r g etZonedimensionallystabilized anode (DSA)110100base metalsGE el ec t r o depositedGE sp r a yprecious metalsCell OverpotentialRelative Cost per Unit AreaTa r g etZonedimensionallystabilized anode (DSA)High Surface Electrode1000x electrode surface.

8 Performance at 1/10 traditional electrode cost Wire arc electrode system ElectrodepositionPlastic Stack One piece stack assembly: minimal part count Molded passages, not +H+H+H+HHHHe-e-e-e-e-e-e-elect rolyt eO2H2H2 OHHcurrent2 H2O + ELECTRICITY O2+ 2 H2elect rodeelect rodeoxygenhydrogenwaterOHHOHHOOe-H+H+H+H +HHHHe-e-e-e-e-e-e-elect rolyt eO2H2H2 OHHOHH current2 H2O + ELECTRICITY O2+ 2 H2elect rodeelect rodeoxygenhydrogenwater+_DiaphragmBipola r conductorPorous CathodePorous AnodeMulticell Bipolar Stackcatholyte passageanolyte passageanodeseparation diaphragmcathode other sideBipolar type half-cells Cathode (-):2H2O + 2e- 2OH-+ H2 Anode (+).

9 2OH- H2O + 2e-+ O2 Electrolysis Cell Basics13 Technical Details - Electrode110100base metalsGE el ec t r o depositedGE sp r a yprecious metalsCell OverpotentialRe l a t i v e Cost p e r Unit AreaTa r g etZonedimensionallystabilized anode (DSA)2004-2005 Project : Wire-arc sprayed high surface elect rodesHigher EfficencyLow er Co stTo d a y : Elect rodeposit ion110100base metalsGE el ec t r o depositedGE sp r a yprecious metalsCell OverpotentialRe l a t i v e Cost p e r Unit AreaTa r g etZonedimensionallystabilized anode (DSA)2004-2005 Project : Wire-arc sprayed high surface elect rodesHigher EfficencyLow er Co stTo d a y : Elect rodeposit ion Achieved target performance with hot spray technique in 2005.

10 Researching electrodeposition for additional cost and performance advantage:- Thinner bipolar plate- Eliminates warping- Coats 3D electrode surfaceGE electrode technology applies a high effective surface area, nickel-based coating to the base metal bipolar plate for high performance at low Details Electrode CELLTank/ HeaterTEST SETUPMESH ELECTRODE Single flow cell Ambient pressure, 80 CFLAT PLATE ELECTRODES Plastic mesh for flow distribution Some oxide left leaching blocked by plastic mesh Cathode mesh applied Higher coated surface areaFLAT , mA/cm2 (Scale removed to protect proprietary information)


Related search queries