Example: confidence

Advanced Environmental Instrumentation - …

Advanced Environmental InstrumentationHarnessing the Power of Mobile ComputingGrayWolf is transforming how to Measure, Data-log and Document worker exposure levels and indoor air quality parameters. The AdvancedSense and DirectSense TOX are powerful Environmental data collection tools; intuitive and Easy-To-Use. Choose from SO2, NO2, NO, CO, H2S, HCN, EtO, Cl2, O2, O3, NH3, HCl, H2, SiH4, AsH3, and more Up to 5 electrochemical gas sensors (plus F / C) per probe Connect multiple probes simultaneously (up to 4) Snap-Shot instantaneous data capture and long-term trending Stores measured data along w/calibration history, text notes, audio notes, user created field note and more On-board measurement tips, industry guidelines and help files Remote Access any WiFi enabled platforms via optiona

Advanced Environmental Instrumentation Harnessing the Power of Mobile Computing GrayWolf is transforming how to Measure, Data-log and Document worker

Tags:

  Advanced, Instrumentation, Environmental, Advanced environmental instrumentation, Graywolf

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Advanced Environmental Instrumentation - …

1 Advanced Environmental InstrumentationHarnessing the Power of Mobile ComputingGrayWolf is transforming how to Measure, Data-log and Document worker exposure levels and indoor air quality parameters. The AdvancedSense and DirectSense TOX are powerful Environmental data collection tools; intuitive and Easy-To-Use. Choose from SO2, NO2, NO, CO, H2S, HCN, EtO, Cl2, O2, O3, NH3, HCl, H2, SiH4, AsH3, and more Up to 5 electrochemical gas sensors (plus F / C) per probe Connect multiple probes simultaneously (up to 4) Snap-Shot instantaneous data capture and long-term trending Stores measured data along w/calibration history, text notes, audio notes, user created field note and more On-board measurement tips, industry guidelines and help files Remote Access any WiFi enabled platforms via optional GrayWolfLive Cal checks, and extensive additional features are highly intuitive and Easy-To-UseSurveyedDocumentedReported graywolf SenSinG SolutionSPh.

2 1-203-402-0477fax: Snap-Shot LogTrend LoggingRealtimeOn-Board DocsExample ScreensToxic Gas Test MetersAdvancedSens e Dire ctSens e TOX Attached Photo(s)AttachedAudio NoteAttachedText NoteProbe Calibration Info Hydrogen Chloride ppmChlorine ppmOxygen % Sulfur Dioxide ppmHydrogen 0 ppmTemperature CMenuSnapFile Log Probe ViewFile Log Probe ViewLive: Fabrication FloorOzone mg/m3 Ammonia mg/m3 Sulfur Dioxide mg/m3 Nitric Oxide mg/m3 Hydrogen Sulfide mg/m3 Temperature CBarometric mmHgMenuSnapSnap Shot log to Lab 4 File Log Probe ViewLogging: Ammonia ppm(1) STEL : 8-hr TWA : Max ppmOptions Full Screen Select 9:14 9:19 9:25 9:29 9:35 Ammonia ppm(1)Menu LiveLog Chem lab 30 secsO3 ppmNH3 ppmSO2 ppmNO ppmH2S ppmTemp F Click the SNAP icon to record measurements, time, date and detailedlocation nameLog at intervals of your choice.

3 Optionally display trend graphs on meterExample AdvancedSense/WolfPack ScreensDocumenting and data-logging gas parameters has never been easier. Provide a descriptive name for files using the virtual keyboard. Record your readings as snap-shot data captures, or as trend logs over time. On-board educational info. Efficiently attach notes, in-situ (or after-the-fact) direct to data files: Text Photos/Video Drawings Custom Audio Events (time-tagged text) Template Field Forms Auto-Fill (data & text)Example WIN 8/7/XP ScreensAdvanced ToxicGas MeasurementIntuitive File NamingAlarm LinesSensor Tips(extensive info for each parameter)Realtime (multi-probe)WolfPack Modular Area MonitorAdvancedSense Handheld Embedded PC MeterChoose Your Platform.

4 graywolf provides embedded computer based meters and Windows tablets that are ideal for the application; or connect probes to your own s TOX kits come with WolfSense PC software for data transfer, analysis, graph/report gen-eration and/or simple export to HelpHydrogen Fluoride ppmFluorine ppmPhosphine ppmChlorine Dioxide ppmPhosgene ppmTemperature F Arsine ppmEthylene Oxide ppmHydrogen Cyanide ppm<< Back Next >> Auto ScrollNew Site New Loc Rename Del OutdoorBldg 74th FloorBoiler RoomBio LabGeneral OfficeLondon UniversityToledo Haz SiteHurricane Sandy AftermathBldg 6 Options Full Screen Select Carbon Monoxide ppmOxygen %Nitric Oxide ppmNitrogen Dioxide ppmSulfur Dioxide ppmTemperature C

5 Chem LabMenu Live LogSensor Basics forThe Nitric Oxide sensor, per the manufacturer (AlphaSense), exhibits the following cross-sensitivity with common gases: NO2 sensitivity measured gas @ 50ppm NO2 < SO2 sensitivity measured gas @ 20ppm SO2 < 4ppm Cl2 sensitivity measured gas @ 10ppm Cl2 < H2S sensitivity measured gas @ 20ppm H2S < ppmLive Notes Log Locs Graph ReviewOzone ppmAmmonia ppmSulfur Dioxide ppmNitric Oxide ppmHydrogen Sulfide ppmCarbon Monoxide ppmTemperature C Hydrogen Fluoride ppmFluorine ppmPhosphine ppmChlorine Dioxide ppmPhosgene ppmTemperature FArsine ppmEthylene Oxide ppmHydrogen Cyanide

6 PpmHydrogen Chloride ppmChlorine ppm<< Back Next >> Auto ScrollLive: Biology ClassroomFile Log Probe ViewFeature InfoSnooze MessagesCloseNext TipAttaching Notes to Location files, or to Sites, provides efficientreliable documentation for surveys. Click on the Notes icon while aLocation is open, and select the note(s) to create/attach. This is apowerful productivity Supplied TabletEntry level platform with great standard features (built-in camera, WiFi)Or Use Your Own Windows PC as the instrument platformRemote Data Access to, and email/text alerts from, any WiFi enabled platforms via optional GrayWolfLive TG-501 Easy to calibrate all parameters Calibration history stored in probe CO & H2S available in a single sensor Allows up to 5 gas sensors in one probe Plus Temperature IQ-610 Carbon Dioxide, Carbon Monoxide, ppb VOCs, %RH, F / C plus one additional gasAS-201 Air Velocity probePC-3016A6-Channel Particle MeterDisplaySelect up to 5 gas sensors in one probe (plus F/ C).

7 Note: Sensors are factory installed (this optimizes their ). Sensors may be added or changed at a later time by graywolf or by an authorized cal lab. Sulfur Dioxide (SO2) Nitrogen Dioxide (NO2) Nitric Oxide (NO) Carbon Monoxide (CO) Hydrogen Sulfide (H2S) Hydrogen Cyanide (HCN) Hydrogen Chloride (HCl) Hydrogen Fluoride (HF) Ethylene Oxide (C2H4O) Chlorine Dioxide (ClO2) Ozone (O3) Oxygen (O2) Ammonia (NH3) Chlorine (Cl2) Hydrogen (H2) Fluorine (F2) Phosphine (PH3) Arsine (AsH3) Silane (SiH4) Phosgene (COCl2)Display units as.

8 PPB PPM g/m mg/m (mass readings are auto compensated w/optional AdvancedSense barometric pressure sensor) EC-202 Any 1 (one) sensor in one probe, plus F/ C Interface these meters to graywolf platforms; and/or use as stand-alones PM-205 Particulate ConcentrationFM-801 Formaldehyde(ppb HCHO)TG-502 VOCs (PID) plus 3 specific gases, %RH, and temperatureNotateData LogOrganizeReportACC-TPD1 tripod shown w/ ACC-MNT2P dual mount and ACC-MNT1 & ACC-MNT3 meter mounts. A soft carry case (PCC-TPDL)is also included with the ACC-TPDL-KIT tripod kituCA-GSXX Gas Calibration Kit.

9 Specific calibration gases are available in various portable cylinder sizespPCC-15 Multi-Probe Security Case(shown at left w/optional ACC-BRK1 brackets for external HCHO or particulate meters)uACC-FIL6 Probe Filters for dirty environments AdvancedSense TOX kits include an AdvancedSense meter, DirectSense TOX TAB kits include a tablet PC. These complete kits also come with WolfSense PC desktop data transfer software, hardshell security case, probe/meter pouches and more. Contact graywolf for details.*HCl, NO, EtO; up to 2, but not all 3 may be installed into a single TG-501 probeSPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT FURTHER NOTICE All gas sensors are electrochemical.

10 One per EC-202 or up to 5 per TG-501 may be included. Typical sensor life, sensor drift and response times vary by sensor. Probe wall mounting brackets, automated reporting software, and many other accessories are available from graywolf . View them on our website at : SenSinG SolutionSannacotty industrial Park, unit 1 Cannacotty, County limerick irelandPh. (353) 61358044fax: (353) 61358160 Measure Smart report efficientlyCA-HD2 Calibration Hood May alternatively be used with air pump to draw sample across sensorsuACC-APUMP1 Portable Air SamplingPump with belt clipuuuPCC-05IQ probe pouch.