Example: biology

Advanced Heating High Efficiency Fire Tube Heating Boiler ...

Advanced Heating & Hot water Systems One of a kind design from the inside, out! High Efficiency fire Tube Heating Boiler up to 97% Efficient 10:1 Turndown Ratio201 8A Closer LookExhaust Vent ConnectionIntake Vent ConnectionStainless Steel fire Tube Heat Exchanger2 Line 40 Character LCD Display - Program & Monitor Boiler OperationSealed Electronic Enclosure(Moisture & Corrosion Resistant)Negative Regulation Gas ValveField ConnectionBoardCondensate SystemIntegrated Digital ControlAlternate Bottom ReturnAl ternate Bottom SupplyAlternate Top SupplyAlternate Top ReturnEasily Removable CoverSpark Ignition system with Flame MonitoringModulating Combustion Blower Assembly Extremely Durable and Reliable Minimal Maintenance RequiredEnergy SavingsUp to AFUE operating Efficiency Outdoor reset lowers operating set point automatically to increase system efficiencyModulating burner input matches system load, conserving energy and increasing system efficiencyLow NOx emission - Reduces environmental impact Unbeatable combined vent length of up to 150 ft 3 PVC pipe (EFT-285)(4 PVC pipe for EFT-399)

Advanced Heating & Hot Water Systems ® One of a kind design from the inside, out! High Efficiency Fire Tube Heating Boiler up to 97% Efficient 10:1 Turndown Ratio

Tags:

  System, Efficiency, Water, Tubes, Advanced, Fire, Boiler, Heating, Advanced heating amp hot water systems, Efficiency fire tube heating boiler

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Advanced Heating High Efficiency Fire Tube Heating Boiler ...

1 Advanced Heating & Hot water Systems One of a kind design from the inside, out! High Efficiency fire Tube Heating Boiler up to 97% Efficient 10:1 Turndown Ratio201 8A Closer LookExhaust Vent ConnectionIntake Vent ConnectionStainless Steel fire Tube Heat Exchanger2 Line 40 Character LCD Display - Program & Monitor Boiler OperationSealed Electronic Enclosure(Moisture & Corrosion Resistant)Negative Regulation Gas ValveField ConnectionBoardCondensate SystemIntegrated Digital ControlAlternate Bottom ReturnAl ternate Bottom SupplyAlternate Top SupplyAlternate Top ReturnEasily Removable CoverSpark Ignition system with Flame MonitoringModulating Combustion Blower Assembly Extremely Durable and Reliable Minimal Maintenance RequiredEnergy SavingsUp to AFUE operating Efficiency Outdoor reset lowers operating set point automatically to increase system efficiencyModulating burner input matches system load, conserving energy and increasing system efficiencyLow NOx emission - Reduces environmental impact Unbeatable combined vent length of up to 150 ft 3 PVC pipe (EFT-285)(4 PVC pipe for EFT-399)

2 Room air intakeBalanced or unbalanced venting systemVersatilityTop and Bottom piping connectionsField convertible from Natural to LP gasWall hung for space savingsCascade up to 8 boilers - linked and sequenced to function together for commercial installationsmake-up watercloselyspacedteesspace Heating zone circuitpurgingvalvesSuper Stor UltraIndirect DHW Tankmixing valvezonecirculatorscoldwaterT/PT/Ppurgi ngvalvesCommercial InstallationStainless Steel fire TubeHeat Exchanger Down fire design, promotes self cleaning of combustion system Durable high grade stainless steel construction provides extended service life Increased thermal mass provides low pressure drop and eliminates short cyclingCompatible with glycol based systemsBuilt-in condensate collection system10:1 turndown Ratio272 Duchaine Blvd, New Bedford, MA 02745 MKTLIT-36 11 / 2018 HTP Comfort Solutions /TEHeating Capacity MBHABCDEFGHJKLMNOPQEFT-285** 5/8 20 5/8 11 1/8 6 7/8 3 7/8 2 1/4 6 14 15 1/4 11 1/8 7 3/4 6 7/8 2 1/4 13 3/8 16 5/8 20 EFT-399** *36736 3/8 23 5/8 13 5/8 8 1/2 4 3/4 2 3/4 7 3/8 18 1/8 18 3/4 13 5/8 9 3/4 8 1/2 2 3/4 16 1/2 19 1/4 25 1/2 OPTIONAL EQUIPMENT - ModBus Adapter- 3 , 4 , 6 Stainless Steel Outside Termination Vent Kit- 3 Concentric Vent Kit- 3 Polypro Vent Kit - 3 Polypro Pipe- 353 Compliant Low water Cutoff w/ Manual Reset- Alarm system to Monitor Failures- PC Connection Kit- Condensate Neutralizer- system Sensor- 3 Speed Pump with integrated Flow Check- LP Conversion KitSTANDARD FEATURES- Up to AFUE- Modulating Burner - 10:1 Turndown ratio- Venting Options - Concentric - 3 Pipe.

3 Balanced or Unbalanced (EFT-285) - 4 Pipe (EFT-399)- Limited 12 Year Warranty- Wall Mounted-Total system Control-The Elite FT is ASME CertifiedINCLUDED IN THE BOX- Temperature and Pressure Gauge- Pressure Relief Valve 80 PSI - Indirect Sensor & Outdoor Sensor- Intake PVC w/ Screens- Exhaust PVC Coupling w/ Screens- Installation Manual- Warranty- Condensation Removal system - Wall Mount* Thermal Efficiency (Not AFUE)ABDRAINOUTLETIN LETCONDENSATEGAS LINEMNOKPJLQAIR IN LETEXHAUSTDFGCEHABDRAINOUTLETIN LETCONDENSATEGAS LINEMNOKPJLQAIR IN LETEXHAUSTDFGCEHABDRAINOUTLETIN LETCONDENSATEGAS LINEMNOKPJLQAIR IN LETEXHAUSTDFGCEHTop ViewSide ViewBottom View** add PU to end of stock code to include a pump Model 285399 InstallationIndoor, Wall Hung, Fully CondensingMinimum / Maximum Input (Btu/Hr)28,500 / 285,00039,900 / 399,000 Heating Capacity (MBH)262367*Turndown Ratio10:110:1 Flue SystemCategory IV, Sealed Combustion Direct Vent, Power VentMinimum Combined Vent Run16 feetMaximum Combined Vent Run3 (150 feet)4 (200 feet)Approved Exhaust Vent MaterialsPVC, CPVC, PP, Stainless SteelShipping Weight (lbs)203298 Gas Supply to 14 WCLPM anifold PressureMin / MaxNG/LP: WCPower Supply120V 60 Hz, Operating ConditionsAmbient Temperature Range: 33 104oF ( 40oC)Product Approvals and Requirements.

4 ANSI / CSA SystemDirect Electronic Spark Ignition / Flame RectificationBurner SystemPremixed Fuel Modulation / Stainless Steel Metal Fiber BurnerGas Valve SystemAir Ratio ValveDimensions(in Inches) water Content (Gallons) Flow Rate @ 30oF T (GPM) Setpoint Temperature Range50 190oF / 32 - 190oF (with Outdoor Reset Curve)DHW Indirect Setpoint Temperature Range70 180oFWater Pressure (PSI)Heat Exchanger MAWP80 Pressure Relief Valve80 Control Panel / Main ControllerLCD Display with LED Indicators / 926 SIT ControlConnection SizesSupply / Return1 1/2 Copper SWTGas Inlet1 NPTFM aterialsCabinetPowder Coated Galvaneal SteelHeat ExchangerS43932 Stainless Steel fire TubeSafety DevicesFlame Rectifier Probe, Dual water Supply Temperature Sensor (199oF), water Pressure Switch (Min. 10 PSI), Freeze Protection, Blocked Condensate Pressure Switch, Condensate Trap with Float, Flue Temperature High Limit Sensor (210oF), Blocked Vent Pressure Switch, Optional UL353 Low water Cut-OffHeat Exchanger Bears the ASME H Stamp201 8


Related search queries