Aegis ring main unitproviding intelligent solutionsTo find out more about us, Switchgear has a policy of continuous research and development and accordingly reserves the right to change the design and specification of its products without prior Middle East FZEPO Box 17335, Jebel Ali, Dubai, United Arab Emirates Tel: +97 148 129 999 Fax: +97 148 129 900 Email: Lucy Switchgear Ltd. Howland Road, Thame, Oxfordshire,OX9 3UJ, United Kingdom Tel: +44 1844 267 267 GeneralTel: +44 1844 267 222 SalesFax: +44 1844 267 223 Email: Lucy Switchgear worldwide officesLucy Asia Pacific Sdn BhdL13A-03-03A, PJX-HM Shah Tower,No16A Jalan Persiaran Barat,46050 Petaling Jaya, Selangor, Malaysia Tel: +603 74910700 Fax: +603 79316923 Email: Electric (Beijing) Co. Ltd. 18 A 1122 : 100027 : +86 1059 231 176 : +86 1059 231 177 : Switchgear Arabia Co.

Aegis ring main unit providing intelligent solutions To find out more about us, visit: www.lucyswitchgear.com Disclaimer Lucy Switchgear has a policy of continuous research and

Tags:

  Unit, Main, Ring, Egia, Aegis ring main unit

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Aegis ring main unit - Lucy Electric

1 Aegis ring main unitproviding intelligent solutionsTo find out more about us, Switchgear has a policy of continuous research and development and accordingly reserves the right to change the design and specification of its products without prior Middle East FZEPO Box 17335, Jebel Ali, Dubai, United Arab Emirates Tel: +97 148 129 999 Fax: +97 148 129 900 Email: Lucy Switchgear Ltd. Howland Road, Thame, Oxfordshire,OX9 3UJ, United Kingdom Tel: +44 1844 267 267 GeneralTel: +44 1844 267 222 SalesFax: +44 1844 267 223 Email: Lucy Switchgear worldwide officesLucy Asia Pacific Sdn BhdL13A-03-03A, PJX-HM Shah Tower,No16A Jalan Persiaran Barat,46050 Petaling Jaya, Selangor, Malaysia Tel: +603 74910700 Fax: +603 79316923 Email: Electric (Beijing) Co. Ltd. 18 A 1122 : 100027 : +86 1059 231 176 : +86 1059 231 177 : Switchgear Arabia Co.

2 Business Centre, Box 35340, Dammam 31488,Saudi ArabiaTel: +966 3 8147 910 Fax: +966 3 8147 914 Email: Lucy Switchgear (South Africa) unit 2, Cranberry Industrial Park, Cranberry StreetLaser Park, Honeydew, 2170, South AfricaTel: +27 11 025 7490 Fax: +27 11 794 3277 Email: Box 1078, Honeydew, 2040 Page 3To find out more about us, Cost effective Safe Maintenance free Simple operation Easy to install Climate independent Automation readyContentsWhy Aegis ?Introduction to Lucy Switchgear 4 Product panorama: Lucy medium voltage and high voltage range 5 Introduction to Aegis 6 Installation and operating conditions 7 Safety features 8 Application examples 9 Aegis range presentation 10 Available configuration 12 Standards 12 Product characteristics 13 General 13 Product presentation User interface and interlocking mechanism L: LBS Load Break Switch 14 Standard features Optional features, factory fitted Optional features also available as retrofit Circuit Breaker.

3 T or V modules 15 Standard features Optional features, factory fitted Optional features also available as retrofit Circuit breaker protection 16 TLF Protection relays Protection CT (Current transformers) for TLF and relays Options and accessories 19 Secondary injection Actuators (motorised) Cable compartment Shunt trip coils Earth Fault Indicators (EFI)Air metering unit 20 Switchgear automation 21 Cable bushings and cable terminations 22 Technical data sheet 23 Dimensions 24 Order form 26 Page 5 Page 4 Lucy Switchgear is a global leader in switching, protection and automation solutions for electrical distribution systems, with over 100 years industry experience. Today the company is a specialist in secondary power distribution, engineering high-performance medium voltage switchgear for utility, industrial and commercial applications, overhead line equipment and providing retrofit and automation solutions to customers internationally.

4 Engineering excellence, based on a long tradition of expertise, coupled with state of the art technology to meet customers stringent specifications, make Lucy Switchgear one of the few companies that can offer truly bespoke solutions. We have the capability to manufacture units for any location, climate or situation and offers a complete product portfolio, with a wide scope of services and dedicated after sales support throughout the product lifecycle. A specialist UK research and development facility, with a continuous programme of R&D, ensures that Lucy Switchgear s products are always at the cutting edge, designed to anticipate the evolving technical and market demands of our customers. And our multi-million pound, purpose built, state of the art UK manufacturing facility provides complete control over Switchgear is a truly international company with offices in China, Dubai, Malaysia and South Africa; manufacturing facilities in the United Arab Emirates, Saudi Arabia and India.

5 And an established global network of industrial partners and contractors operating in over 50 countries main unit range evolutionSabreIntroduction to Lucy SwitchgearProduct panorama: Lucy medium voltage and high voltage rangeSwitch disconnectorsRatedvoltage(up to)Mode offault current interruptionInsulationmediumRatedcurrent (up to)MountingInstallationconditionOperatio n24kVVacuumSF6630 AGround /TransformerIndoor /OutdoorLocal /RemoteAegis24kVVacuumSF6630 AGround /TransformerIndoor /OutdoorLocal /RemoteSabre36kV-Air800 APoleOutdoorLocal /RemoteRapier AX38V-SF6630 APoleOutdoorLocal /RemoteRapier /TransformerIndoor /OutdoorLocal /TransformerIndoor /OutdoorLocal /RemoteScimitar145kV-Air2500 AStructureOutdoorLocal /RemoteRapier DSBRing main units Page 7 Page 6IP54 Outdoor metal clad non extensible units onlyTemperature De-rating Curves700650600550500450404550 Ambient Temperature CRated Current (Amps)556065400350300630A at 40 Ci.

6 Indoor and outdoor type unitsii. Ambient temperature for operation without derating: 40 C (for higher temperature applications please refer to temperature derating curve below) iii. Average value over 24 hours max: 40 Civ. Maximum altitude for operation without derating: 1000m (above sea level)*v. Insulation medium: SF6 Gasvi. Rated pressure at +20 C: MPavii. Interruption medium: vacuum* For higher altitude applications please contact local Lucy Switchgear sales Indoor extensible and non extensibleAegis is a new generation of ring main Units mainly designed for secondary distribution networks up to 24kV. This range is available in indoor and outdoor formats to suit various application needs. All the live parts and switching functions are insulated with SF6 gas and sealed in a stainless steel tank ensuring a high level of reliability, personnel safety and virtually maintenance free structural tank welding is performed by a robotic welding process ensuring high reliability with a product life expectancy of more than 30 years.

7 The housing is fully treated using zinc coated steel and electro statically applied, oven cured paint to resist degradation from pollution and harsh climatic conditions. The transformer protection is by Vacuum Circuit Breaker. On request, the units can be supplied with integrated automation for remote monitoring and control : 12kV, and 24kV ratings Extensible and non extensible range with up to 4 switching functions in a single tank Hermetically sealed stainless steel tank insensitive to environment Intuitive single line mimic diagram for simple and safe operation Vacuum Circuit Breaker enclosed in an SF6 insulated tank for extra protection against corrosion and pollution Provision for motor actuators for remote operation and control Integrated cable testing facility on front face eliminating the need for cable disconnection Suitable for indoor and outdoor applications Various protection options (TLF, relays)

8 To suit customer needs Low roof height designed for kiosks and mini substations Easy integration with SCADA network for remote operation and control Standard RAL7032 paint finish with other colours available on requestIntroduction to AegisInstallation and operating conditions Page 9 Page 8 Operation mechanism The mechanism consists of one operating shaft and one selector. The operating shaft is used for switching ON / OFF (Mains or Earth) and the selector is used for selection of the Mains or Earth positions. It is impossible to simultaneously close the Load Break Switch or Circuit Breaker and the Earth mechanism incorporates mechanical interlocks and padlocking facilities to improve operator reflex mechanism:Ensures a time delay between switching operations to allow sufficient time for the main breaker to trip and clear a Arc withstandAegis SF6 Gas insulated stainless steel tanks are fully internal arc rated and this feature is also available on the cable compartment (optional) to ensure maximum operator safety in the event of internal faults.

9 As standard, all the tanks are rated for AF (operator safety from the front of the unit ) and there is an option to request for AFL (front and side) and AFLR (front, side and back of the unit ).For more details on IAC ratings, please refer to the technical data sheet on page socketsNeon indicator with push-to-test buttonsSafety featuresEarth and test facilityThe cable earth and test facility is an optional feature on the Load Break Switch and the Circuit Breaker. It is located at the front of the unit for ease of access. It is used for testing cable insulation and to locate faults in the circuit without the need to remove the main cables from the cable compartment, which improves the operator cable test access cover is fully interlocked and cannot be opened until the Load Break Switch or Circuit Breaker Switch is in Earth ON position.

10 The test bushings are earthed with a star bar which has to be removed for cable tests. Earth bar in cable compartmentA fully rated copper earth bar is mounted inside the cable compartment. This earth bar is used to connect the screened cable connectors through M12 size bolts. The bar runs through the width of the unit and protrudes 125mm to the rear of the cable compartment or connection to the main earthing system. For additional safety it is not possible to remove it while unit is live. VPISVPIS (Voltage Presence Indication System) is an optional feature in the Aegis range. It is used for checking the presence of voltages in the cables. The VPIS gets a voltage signal through the voltage divider built into the cable bushings. They can also be fitted with neon lights and momentary latching push buttons to show voltage presence without needing external testing types of voltage presence indication device are offered: Pfisterer sockets Neon indicators with push-to-test buttons and phase comparator socketsCable compartmentThe cable compartments are located at the front of the units with horizontal mounted DIN 400 type C bushings for ease of cable connection.