Example: stock market

Agilent 7800/7900 ICP-MS

Agilent 7800/7900 ICP-MS . Site Preparation Checklist Agilent Technologies Notices No part of this manual may be reproduced in Technology Licenses C AU T I O N. any form or by any means (including elec- tronic storage and retrieval or translation The hardware and/or software described in into a foreign language) without prior agree- this document are furnished under a license A CAUTION notice denotes a haz- ment and written consent from Agilent Tech- and may be used or copied only in accor- ard. It calls attention to an operating nologies, Inc. as governed by United States dance with the terms of such license. procedure, practice, or the like that, and international copyright laws. if not correctly performed or adhered Restricted Rights Legend to, could result in damage to the Manual Part Number If software is for use in the performance of a product or loss of important data.

installation dependent upon the readiness of your laboratory. 2 Should your site not be ready for whatever reasons, please contact Agilent as soon as possible to re-arrange any services that have been purchased. 3 Other optional services such as …

Tags:

  Installation

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Agilent 7800/7900 ICP-MS

1 Agilent 7800/7900 ICP-MS . Site Preparation Checklist Agilent Technologies Notices No part of this manual may be reproduced in Technology Licenses C AU T I O N. any form or by any means (including elec- tronic storage and retrieval or translation The hardware and/or software described in into a foreign language) without prior agree- this document are furnished under a license A CAUTION notice denotes a haz- ment and written consent from Agilent Tech- and may be used or copied only in accor- ard. It calls attention to an operating nologies, Inc. as governed by United States dance with the terms of such license. procedure, practice, or the like that, and international copyright laws. if not correctly performed or adhered Restricted Rights Legend to, could result in damage to the Manual Part Number If software is for use in the performance of a product or loss of important data.

2 Do G8400-90020 Government prime contract or subcon- not proceed beyond a CAUTION. tract, Software is delivered and licensed as notice until the indicated conditions Commercial computer software as defined are fully understood and met. Edition in DFAR (June 1995), or as a Rev. B, June 2015 commercial item as defined in FAR. Agilent Technologies (a) or as Restricted computer soft- ware as defined in FAR (June NOTE. 9-1 Takakura-cho, Hachioji-shi, 1987) or any equivalent agency regulation or Tokyo 192-8510 Japan contract clause. Use, duplication or disclo- A NOTE contains helpful informa- Agilent Technologies, Inc. 2015 sure of Software is subject to Agilent Tech- tion on the usage - it does not nologies' standard commercial license denote a hazard.

3 Terms, and non-DOD Departments and Agen- Warranty cies of the Government will receive no The material contained in this docu- greater than Restricted Rights as defined in ment is provided as is, and is sub- FAR (c)(1-2) (June 1987). Gov- ject to being changed, without notice, ernment users will receive no greater than Limited Rights as defined in FAR in future editions. Further, to the maxi- (June 1987) or DFAR (b)(2). mum extent permitted by applicable (November 1995), as applicable in any tech- law, Agilent disclaims all warranties, nical data. either express or implied, with regard to this manual and any information Safety Notices contained herein, including but not limited to the implied warranties of merchantability and fitness for a par- WA R N I N G.

4 Ticular purpose. Agilent shall not be liable for errors or for incidental or A WARNING notice denotes a haz- consequential damages in connection ard. It calls attention to an operat- with the furnishing, use, or perfor- ing procedure, practice, or the like mance of this document or of any infor- that, if not correctly performed or mation contained herein. Should adhered to, could result in personal Agilent and the user have a separate injury or death. Do not proceed written agreement with warranty beyond a WARNING notice until terms covering the material in this document that conflict with these the indicated conditions are fully terms, the warranty terms in the sepa- understood and met. rate agreement shall control.

5 Contents Contents Checklist and Requirement Summary 5. Customer Responsibilities 5. Important Customer Information 6. Space, Weight and Access Requirements 7. Environmental Conditions and Site Requirements 10. Power Consumption and Configuration 12. Cooling Water Requirements 14. Gas Requirements 15. Essential Requirements for Cell Gas installation 16. Communications 17. Laboratory Supply Requirements 18. Other Requirements 19. Important Customer Web Links 20. Appendix 21. Detailed Environmental Conditions and Site Requirements 21. Detailed Power Consumption and Configuration 23. Detailed Cooling Water Requirements and Operating Supplies 28. Detailed Gas Requirements 29. Agilent 7800/7900 ICP-MS Site Preparation Checklist 3.

6 Contents This page is intentionally left blank. 4 Agilent 7800/7900 ICP-MS Site Preparation Checklist Checklist and Requirement Summary Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation , please refer to this specification or set of requirements. Correct site preparation is the first key step in ensuring that your instruments and software systems operate reliably over an extended lifetime. This document is an information guide AND checklist prepared for you that outlines the supplies, consumables, space and utility requirements for your equipment for your site. Customer Responsibilities Make sure your site meets the following prior specifications before the installation date.

7 This checklist includes information on these product G8421A. and G8403A. For details, see specific sections within this checklist, including: The necessary laboratory or bench space is available. Refer to "Space, Weight and Access Requirements" on page 7. The environmental conditions for the lab as well as laboratory gases and plumbing. Refer to "Environmental Conditions and Site Requirements" on page 10. The power requirements related to the product ( , number & location of electrical outlets). Refer to "Power Consumption and Configuration" on page 12. The cooling water requirements for the product and installation . Refer to "Cooling Water Requirements" on page 14. The gas requirements for the product and installation .

8 Refer to "Gas Requirements" on page 15. The required network communication configuration. Refer to "Communications" on page 17. The required items and tools necessary for the product and installation . Refer to "Laboratory Supply Requirements" on page 18. For other product specific information, refer to "Other Requirements" on page 19. Agilent Technologies service providers will not install your Agilent ICP- MS. system until an adequate exhaust system is present and functioning. Refer to "Environmental Conditions and Site Requirements" on page 10. If Agilent is delivering installation and familiarization services, users of the instrument should be present throughout these services; otherwise, they will miss important operational, maintenance and safety information.

9 Agilent 7800/7900 ICP-MS Site Preparation Checklist 5. Important Customer Information 1 If you have questions or problems in providing anything described as part of the Customer Responsibilities above, please contact your local Agilent or partner support/service organization for assistance prior to delivery. In addition, Agilent and/or its partners reserve the right to reschedule the installation dependent upon the readiness of your laboratory. 2 Should your site not be ready for whatever reasons, please contact Agilent as soon as possible to re- arrange any services that have been purchased. 3 Other optional services such as additional training, operational qualification (OQ) and consultation for user- specific applications may also be provided at the time of installation when ordered with the system, but should be contracted separately.

10 6 Agilent 7800/7900 ICP-MS Site Preparation Checklist Space, Weight and Access Requirements Identify the laboratory bench space before your system arrives based on the information in Table 2. Pay special attention to the total height and total weight requirements for all system components you have ordered and avoid bench space with overhanging shelves. Also pay special attention to the total weight of the modules you have ordered to ensure your laboratory bench can support this weight. Special Notes 1 The Agilent 7800/7900 ICP- MS, its data system and accessories will be delivered to your site in large and small shipping containers. Note the size of the largest shipping container below. 2 The containers will be delivered in a large truck.


Related search queries