Example: quiz answers

Air Conditioning Technical Data

Air ConditioningTechnical DataConcealed ceiling unitEEDEN16-100 FDXM-F split - Sky Air FDXM-F1 Indoor Unit FDXM-FTABLE OF CONTENTSFDXM-F1 Features .. 22 Specifications .. 3 Technical Specifications .. 3 Electrical Specifications .. 33 Options .. 44 Dimensional drawings .. 55 Centre of gravity.. 76 Piping diagrams .. 97 Wiring diagrams .. 10 Wiring Diagrams - Single Phase .. 108 Sound data .. 11 Sound Pressure Spectrum - Cooling .. 11 Sound Pressure Spectrum - Heating .. 129 Fan characteristics .. 13 Indoor Unit FDXM-F1 split - Sky Air FDXM-F21 FeaturesIndoor UnitSplit - SkFDXM-FConcealed cCompact concealed ceiling unit, with a height of only 200mm Compact dimensions, can easily be mounted in a ceiling void of only 240mm Discretely concealed in the ceiling: only the suction and discharge grilles are visible Choosing for an R-32 product, reduces the environmental impact with 68% compared to R-410A and leads directly to lower energy consumption thanks to its high energy efficiency Low energy consumption thanks to DC fan motor Medium external static pressure up to 40Pa facilitates unit use with flexible ducts of varying lengthsFan onlyFan s

• Indoor Unit • FDXM-F 1 2 • Split - Sky Air • FDXM-F 1 Features ktc iS nd Ue - l r a tFC oe - i oc M l dn X npDo ISFCompact concealed ceiling unit, with a height of only 200mm • Compact dimensions, can easily be mounted in a ceiling void of only

Tags:

  Data, Technical, Split, Conditioning, Air conditioning technical data

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Air Conditioning Technical Data

1 Air ConditioningTechnical DataConcealed ceiling unitEEDEN16-100 FDXM-F split - Sky Air FDXM-F1 Indoor Unit FDXM-FTABLE OF CONTENTSFDXM-F1 Features .. 22 Specifications .. 3 Technical Specifications .. 3 Electrical Specifications .. 33 Options .. 44 Dimensional drawings .. 55 Centre of gravity.. 76 Piping diagrams .. 97 Wiring diagrams .. 10 Wiring Diagrams - Single Phase .. 108 Sound data .. 11 Sound Pressure Spectrum - Cooling .. 11 Sound Pressure Spectrum - Heating .. 129 Fan characteristics .. 13 Indoor Unit FDXM-F1 split - Sky Air FDXM-F21 FeaturesIndoor UnitSplit - SkFDXM-FConcealed cCompact concealed ceiling unit, with a height of only 200mm Compact dimensions, can easily be mounted in a ceiling void of only 240mm Discretely concealed in the ceiling.

2 Only the suction and discharge grilles are visible Choosing for an R-32 product, reduces the environmental impact with 68% compared to R-410A and leads directly to lower energy consumption thanks to its high energy efficiency Low energy consumption thanks to DC fan motor Medium external static pressure up to 40Pa facilitates unit use with flexible ducts of varying lengthsFan onlyFan speed stepsDry programmeAir filterWeekly timer24 hour timer Infrared remote controlWired remote controlCentralised controlAuto-restartSelf diagnosisMulti model application32 split - Sky Air FDXM-F3 Indoor Unit FDXM-F2 Specifications2-1 Technical SpecificationsFDXM25 FFDXM35 FFDXM50 FFDXM60 FPower ,150/620 Packed unitHeight/Width/Depthmm274/906/751266/1 ,306/751 WeightUnitkg2130 Packed unitkg2937 Heat exchangerLengthmm500900 RowsQuantity32 Fin type 7 Hi-XDFinTypeMulti slit finAir filterTypeRemovable / washable / mildew proofFanTypeSirocco fanAir flow rateCooling Highm Highm static motorModelKFD-280-44-8 AKFD-280-65-8 ASpeedSteps3 Cooling High/Medium/Lowrpm1,270/1,180/1,0901,270 /1,180/1,0801,280/1,160/1,040 Heating High/Medium/Lowrpm1,270/1,180/1,0901,270 /1,180/1,0801,280/1,160/1,040 Sound power levelCoolingdBA535556 HeatingdBA535556 Sound pressure systemsInfrared remote controlBRC4C65 Wired remote controlBRC1D52 RefrigerantTypeR-32 Piping ( 20 26)

3 Heat insulationBoth liquid and gas pipesTemperature controlMicrocomputer control2-2 Electrical SpecificationsFDXM25 FFDXM35 FFDXM50 FFDXM60 FPower supplyNameV1 Phase1~FrequencyHz50 VoltageV230220-240 CurrentNominal running current (RLA) - Indoor Unit FDXM-F3 split - Sky Air FDXM-F43 Options3 - 1 Options34 split - Sky Air FDXM-F5 Indoor Unit FDXM-F4 Dimensional drawings4 - 1 Dimensional Drawings Indoor Unit FDXM-F4 split - Sky Air FDXM-F64 Dimensional drawings4 - 1 Dimensional Drawings35 split - Sky Air FDXM-F7 Indoor Unit FDXM-F5 Centre of gravity5 - 1 Centre of Gravity Indoor Unit FDXM-F5 split - Sky Air FDXM-F85 Centre of gravity5 - 1 Centre of Gravity36 split - Sky Air FDXM-F9 Indoor Unit FDXM-F6 Piping diagrams6 - 1 Piping Diagrams Indoor Unit FDXM-F7 split - Sky Air FDXM-F107 Wiring diagrams7 - 1 Wiring Diagrams - Single Phase38 split - Sky Air FDXM-F11 Indoor Unit FDXM-F8 Sound data8 - 1 Sound Pressure Spectrum.

4 Cooling Indoor Unit FDXM-F8 split - Sky Air FDXM-F128 Sound data8 - 2 Sound Pressure Spectrum - Heating39 split - Sky Air FDXM-F13 Indoor Unit FDXM-F9 Fan characteristics9 - 1 Fan Characteristics Indoor Unit FDXM-F9 split - Sky Air FDXM-F149 Fan characteristics9 - 1 Fan CharacteristicsDaikin Europe participates in the Eu-rovent Certification programme for LiquidChilling Packages (LCP), Air handling units(AHU), Fan coil units (FCU) and variable re-frigerant flow systems (VRF) Check ongo-ing validity of certificate or 11/15 Copyright Daikin The present publication supersedes EEDEN15-100 The present leaflet is drawn up by way of information only and does notconstitute an offer binding upon Daikin Europe Daikin Europe compiled the content of this leaflet to the best of its knowledge.

5 Noexpress or implied warranty is given for the completeness, accuracy, re-liability or fitness for particular purpose of its content and the productsand services presented therein. Specifications are subject to changewithout prior notice. Daikin Europe explicitly rejects any liability forany direct or indirect damage, in the broadest sense, arising from or re-lated to the use and/or interpretation of this leaflet. All content is copy-righted by Daikin Europe products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - - BE 0412 120 336 - RPR Oost


Related search queries