Air Conditioning Technical Data FXAQ-A

Air Conditioning Technical Data FXAQ-A . > FXAQ15 AUV1B > FXAQ63 AUV1B. > FXAQ20 AUV1B. > FXAQ25 AUV1B. > FXAQ32 AUV1B. > FXAQ40 AUV1B. > FXAQ50 AUV1B. ,QGRRU 8 QLW );$4 $. 7$%/( 2) &217(176. );$4 $. 1 Features .. 2. 2 Specifications .. 3. Technical Specifications .. 3. Electrical Specifications .. 3. 3 Electrical data .. 5. 4 Safety device settings.. 6. 5 Options.. 7. 6 Dimensional drawings .. 8. 7 Centre of gravity .. 10. 8 Piping diagrams .. 12. 9 Wiring diagrams .. 13. Wiring Diagrams - Single Phase .. 13. 10 Sound data .. 14. Sound Pressure Spectrum .. 14. 959 6\VWHPV );$4 $.

959 6\vwhpv );$4 $ )hdwxuhv $:g h w q x r p o o d w l q 8 u r r g q ,v p h w v \ 6 9 5 9 4 $ ; ))ru urrpv zlwk qr idovh fhlolqjv qru iuhh iorru vsdfh )odw vw\olvk iurqw sdqho eohqgv hdvlo\ zlwklq dq\ lqwhulru gpfru dqg lv hdvlhu wr fohdq &dq hdvlo\ eh lqvwdoohg lq …

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Air Conditioning Technical Data FXAQ-A

1 Air Conditioning Technical Data FXAQ-A . > FXAQ15 AUV1B > FXAQ63 AUV1B. > FXAQ20 AUV1B. > FXAQ25 AUV1B. > FXAQ32 AUV1B. > FXAQ40 AUV1B. > FXAQ50 AUV1B. ,QGRRU 8 QLW );$4 $. 7$%/( 2) &217(176. );$4 $. 1 Features .. 2. 2 Specifications .. 3. Technical Specifications .. 3. Electrical Specifications .. 3. 3 Electrical data .. 5. 4 Safety device settings.. 6. 5 Options.. 7. 6 Dimensional drawings .. 8. 7 Centre of gravity .. 10. 8 Piping diagrams .. 12. 9 Wiring diagrams .. 13. Wiring Diagrams - Single Phase .. 13. 10 Sound data .. 14. Sound Pressure Spectrum .. 14. 959 6\VWHPV );$4 $.

2 ,QGRRU 8 QLW );$4 $. )HDWXUHV. G WHV LWP QH 8XW RV PU\$ R6 RO4 G$9O Q;5D )RU URRPV ZLWK QR IDOVH FHLOLQJV QRU IUHH IORRU VSDFH. )9,: )ODW VW\OLVK IURQW SDQHO EOHQGV HDVLO\ ZLWKLQ DQ\ LQWHULRU GpFRU DQG LV 7KH DLU LV FRPIRUWDEO\ VSUHDG XS DQG GRZQZDUGV WKDQNV WR . HDVLHU WR FOHDQ GLIIHUHQW GLVFKDUJH DQJOHV WKDW FDQ EH SURJUDPPHG YLD WKH UHPRWH. FRQWURO. &DQ HDVLO\ EH LQVWDOOHG LQ ERWK QHZ DQG UHIXUELVKPHQW SURMHFWV. 0 DLQWHQDQFH RSHUDWLRQV FDQ EH SHUIRUPHG HDVLO\ IURP WKH IURQW RI WKH . 5 HGXFHG HQHUJ\ FRQVXPSWLRQ WKDQNV WR VSHFLDOO\ GHYHORSHG '& IDQ. XQLW. PRWRU.

3 +RPH OHDYH )DQ RQO\ $XWR FRROLQJ :KLVSHU TXLHW 9 HUWLFDO DXWR )DQ VSHHG 'U\ SURJUDPPH $LU ILOWHU :HHNO\ WLPHU. RSHUDWLRQ KHDWLQJ VZLQJ VWHSV. FKDQJHRYHU. ,QIUDUHG UHPRWH :LUHG UHPRWH &HQWUDOLVHG $XWR UHVWDUW 6 HOI GLDJQRVLV 0 XOWL WHQDQW 'UDLQ SXPS NLW. FRQWURO FRQWURO FRQWURO. 959 6\VWHPV );$4 $. ,QGRRU 8 QLW );$4 $. 6 SHFLILFDWLRQV. 2-1 Technical Specifications Power input - 50Hz Cooling Nom. kW. FXAQ15A. FXAQ20A FXAQ25A. FXAQ32A FXAQ40A. FXAQ50A. FXAQ63A.. Heating Nom. kW Dimensions Unit Height mm 290. Width mm 795 1,050. Depth mm 266 269 . Weight Unit kg 12 15.

4 Casing Colour White Heat exchanger Rows Quantity 2. Fin pitch mm Face area m Stages Quantity 14. Fan Type Cross flow fan Air flow rate - 50Hz Cooling High m /min Low m /min Fan motor Model KFD-280-40-8K ARW30W8P43DK. Drive Direct drive Air filter Type Washable resin net Sound power level Cooling High dBA Sound pressure level Cooling High dBA Low dBA Heating High dBA Low dBA Refrigerant Type R-410A. Control Electronic expansion valve Piping connections Liquid Type Flare connection OD mm 6,35 9,52. Gas Type Flare connection OD mm Drain VP13 ( 15 18). Sound absorbing insulation Foamed polystyrene / polyethylene Control systems Infrared remote control BRC7EA628 / BRC7EA629.

5 Wired remote control BRC1E61. Simplified wired remote control for hotel - applications Standard Accessories : Installation and operation manual; Quantity : 1;. Standard Accessories : Installation panel; Quantity : 1;. Standard Accessories : Paper pattern for installation; Quantity : 1;. Standard Accessories : Insulation tape; Quantity : 1;. Standard Accessories : Clamps; Quantity : 1;. Standard Accessories : Screws; Quantity : 1;. 2-2 Electrical Specifications FXAQ15A FXAQ20A FXAQ25A FXAQ32A FXAQ40A FXAQ50A FXAQ63A. Power supply Name V1. Phase 1~. Frequency Hz 50.

6 Voltage V 220-240. Current - 50Hz Minimum circuit amps (MCA) A Maximum fuse amps (MFA) A 16. Full load amps Total A (FLA). 959 6\VWHPV );$4 $ . ,QGRRU 8 QLW );$4 $. 6 SHFLILFDWLRQV. 1 RWHV. Cooling: indoor temp. 27 CDB, CWB; outdoor temp. 35 CDB; equivalent piping length: 5m (horizontal). Heating: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; equivalent refrigerant piping: 5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Sound levels are measured in an anechoic room. Operation sound differs with operation and ambient conditions The sound pressure level is measured via a microphone at 1m distance of the unit.

7 Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. Maximum allowable voltage range variation between phases is 2%. MCA/MFA: MCA = x FLA. Contains fluorinated greenhouse gases Instead of a fuse, use a circuit breaker Select wire size based on the value of MCA. Next lower standard fuse rating minimum 16A. MFA 4 x FLA. 959 6\VWHPV );$4 $. ,QGRRU 8 QLW );$4 $. (OHFWULFDO GDWD. (OHFWULFDO 'DWD. &y Y . Indoor unit Power supply IFM Input (W). Model name Hz Voltage Voltage range MCA MFA kW FLA Cooling Heating MAX.

8 50Hz 264V.. FXAQ15 AUV1B 50 220~240 0,30 16 0,040 0,2 17 25. MIN. 50Hz 198V. MAX. 50Hz 264V. FXAQ20 AUV1B 50 220~240 0,30 16 0,040 0,2 19 29. MIN. 50Hz 198V. MAX. 50Hz 264V. FXAQ25 AUV1B 50 220~240 0,40 16 0,040 0,3 28 34. MIN. 50Hz 198V. MAX. 50Hz 264V. FXAQ32 AUV1B 50 220~240 0,40 16 0,040 0,3 30 35. MIN. 50Hz 198V. MAX. 50Hz 264V. FXAQ40 AUV1B 50 220~240 0,40 16 0,043 0,3 20 20. MIN. 50Hz 198V. MAX. 50Hz 264V. FXAQ50 AUV1B 50 220~240 0,50 16 0,043 0,4 33 39. MIN. 50Hz 198V. MAX. 50Hz 264V. FXAQ63 AUV1B 50 220~240 0,70 16 0,043 0,6 50 60. MIN. 50Hz 198V. Notes 1) The units are suitable for use with electrical systems in which the voltage supplied to the unit terminals is not below or above the listed range limits.

9 2) The maximum allowable voltage that is unbalanced between phases is 2 %. 3) MCA/MFA. MCA = X FLA. MFA 4 X FLA. 4) Select the wire size according to the MCA. 5) Use a circuit breaker instead of a fuse. Symbols MCA: Minimum Circuit Ampere [A]. MFA: Maximum Fuse Ampere [A]. kW: Fan motor rated output [kW]. FLA: Full Load Ampere [A]. IFM: Indoor fan motor . 959 6\VWHPV );$4 $ . ,QGRRU 8 QLW );$4 $ . 6 DIHW\ GHYLFH VHWWLQJV. 6 DIHW\ 'HYLFH 6 HWWLQJV. &y Y .. Safety devices 15 20 25 32 40 50 60. FXAQ~AUV1B PCB fuse 250V, . 959 6\VWHPV );$4 $ . ,QGRRU 8 QLW );$4 $. 2 SWLRQV.

10 2 SWLRQV. &y Y . Availability VRV. FXAQ15 AUV1B. FXAQ20 AUV1B. Option kit Product name FXAQ25 AUV1B. FXAQ32 AUV1B . FXAQ40 AUV1B. FXAQ50 AUV1B. FXAQ63 AUV1B. Individual control Wired remote control BRC1H51W/S/K, BRC1E53A/B/C . systems Wireless remote control (H/P) BRC7EA628, BRC7EA629 . Centralised Central remote control DCS302C51/DCS302CA61 . control systems Unified ON/OFF controller DCS301A51/DCS301BA61 . Schedule timer DST301B51/DST301BA61 . Adaptor for wiring KRP1B56 . Wiring adaptor for electrical appendices 1 KRP2A51 , KRP2A61 . Wiring adaptor for electrical appendices 2 KRP4AA51.