C/CW/CC SeriesAir Control Valves3-Way, 3-Port, 2-Position4-Way, 4-Port, 2-PositionCatalog 0640-E/USAA pril 2004 Parker Hannifin CorporationPneumatic DivisionRichland, OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBEDHEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provideproduct and/or system options for further investigation by users having technical expertise. It is important that you analyzeall aspects of your application including consequences of any failure, and review the information concerning the product orsystem in the current product catalog. Due to the variety of operating conditions and applications for these products orsystems, the user, through its own analysis and testing, is solely responsible for making the final selection of the productsand systems and assuring that all performance, safety and warning requirements of the application are products described herein, including without limitation, product features, specifications, designs, availability and pricing,are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without of SaleThe items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or itsa

Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatic Pneumatic CJ1 CWJ1 C10 CW10 Application These 3-Way, 2-Position, remote pressure operated spool

Tags:

  Control, Position, Valves, Operated, Ports, Spool, 2 position, Air control valves 3 way, Operated spool

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Air Control Valves 3-Way, 3-Port, 2-Position 4 …

1 C/CW/CC SeriesAir Control Valves3-Way, 3-Port, 2-Position4-Way, 4-Port, 2-PositionCatalog 0640-E/USAA pril 2004 Parker Hannifin CorporationPneumatic DivisionRichland, OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBEDHEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provideproduct and/or system options for further investigation by users having technical expertise. It is important that you analyzeall aspects of your application including consequences of any failure, and review the information concerning the product orsystem in the current product catalog. Due to the variety of operating conditions and applications for these products orsystems, the user, through its own analysis and testing, is solely responsible for making the final selection of the productsand systems and assuring that all performance, safety and warning requirements of the application are products described herein, including without limitation, product features, specifications, designs, availability and pricing,are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without of SaleThe items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or itsauthorized distributors.

2 This offer and its acceptance are governed by the provisions stated on the separate page of thisdocument entitled Offer of Sale . Copyright 2004, Parker Hannifin Corporation. All Rights Reserved!Parker Hannifin CorporationPneumatic DivisionRichland, Basic Valve Features ..2C/CW Model Number Index ..3 Single Solenoid & Remote PressureCJ1, CWJ1, C10, CW10 ..4 Double Remote Pressure & Cam OperatedC12, CW12, C2, OperatedC94, CW94, C92, CW92, C13, CW13, C9, CW9 .. 6-7 Hand OperatedC5, CW5, C4, & Foot OperatedC3, CW3, Guard / C/CW Technical Data ..10 Dimensions3-Way, 2-Position Single , 2-Position Remote , 2-Position Heavy Duty Cam , 2-Position Cam operated ..143-Way, 2-Position Hand operated ..153-Way, 2-Position Foot operated & Guard ..16CC Basic Valve Features ..18CC Model Number Index ..19 Single & Double SolenoidCCJ1, CCJ11 ..20 Remote PressureCC10, OperatedCC92, CC94, CC9, CC13, CC2 ..22-24 Hand OperatedCC3, CC4, CC5.

3 24-25 Foot Technical Data ..27 Dimensions4-Way, 4-Port, 2-Position Single Solenoid ..274-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure ..284-Way, 4-Port, 2-Position Cam operated ..294-Way, 4-Port, 2-Position Cam & Hand operated ..304-Way, 4-Port, 2-Position Foot operated & Guard ..31 OptionsFlow Control Cross of Sale ..351 C/CW/CC Series ValvesTable of ContentsCatalog 0640-E/USAT able of ContentsParker Hannifin CorporationPneumatic DivisionRichland, SeriesFeatures 3-Way, 2-Position . Single Solenoid. Single Air Pilot. Manual, cam, hand, and foot operators. Inline mounting. Wall or base mounting. ports : 1/4 and 3/8 inch. No minimum operating pressure. Cv Suitable for vacuum service. May be used as diverter. Solenoid valve is CSA approved. Body - sandcast C/CW Series ValvesAir Control ValvesCatalog 0640-E/USAB asic Valve FeaturesParker Hannifin CorporationPneumatic DivisionRichland, C/CW Series ValvesAir Control ValvesCatalog 0640-E/USAM odel Number Index Basic Valve Port Coil Series Operator Size Option Modification C J1 25 01 --Valve OperatorsManual/Mechanical 2 Ball Cam, Spring Return 3 Palm Button, Spring Return 4 Hand Toggle, Non-Locking 5 Hand Toggle, Locking 6 Non-Locking Foot Actuator * 10 Remote Pressure, Spring Return 12 Double Remote Pressure 13 Roller Cam, Spring Return 92 Heavy Duty, Uni-Directional Roller Lever, Spring Return 94 Heavy Duty, Bi-Directional Roller Lever, Spring Return Alternating Current Solenoids J1 Single Solenoid, Spring Return, Non-Locking Override* Available in 1/4" Series C 2-Position , 3-Way, 3-Port, NC/NO Inline Valve, Horizontal Mounting CW 2-Position , 3-Way, 3-Port.

4 NC/NO Inline Valve, Vertical Mounting (Wall Mount)Port Size 25 1/4" 37 3/8" ** Not available with operator 6 Modification Blank None M28 Viton SealsCoil Option - Solenoid 01 120V/60 HzNote: Refer to back of Catalog for Cross Reference Information.(Revised 04-06-11)Parker Hannifin CorporationPneumatic DivisionRichland, 3-Way, 2-Position , remote pressure operated spoolvalves are used to operate single acting cylinders. Theycan be used as normally closed or normally open, and asa for inline use. Use C Series for mounting tohorizontal surfaces. Use CW Series for mounting to or Spring Returned position of the spool Pressure at inlet port A is blocked and port 0 is connected toport B . When pilot is energized, port A is connected to port 0 and port B is blocked. Because of the area-balancedconstruction of the spool , either port A or port B may be usedas the inlet supply port. Pressure to port A valve is normallyclosed valve.

5 Pressure to port B is normally open 3-Way, 2-Position , direct solenoid operated , (maintainedcontact) spool Valves are used to operate single actingcylinders. They can be used as normally closed or normallyopen, and as a for inline use. Use C Series for mounting tohorizontal surfaces. Use CW Series for mounting to De-energized Port A is blocked, port 0 isconnected to port B . When solenoid is energized, port A isconnected to port 0 and port B is blocked. Because of thearea-balanced construction of the spool , either port A or port B may be used as the inlet supply port. Pressure to port A valve is normally closed valve. Pressure to port B valve isnormally open Selection InformationPort SizeDescriptionModel Number1/4" NPTBase MountedC10253/8" NPTBase MountedC1037 Port SizeDescriptionModel Number1/4" NPTWall MountedCW10253/8" NPTWall MountedCW1037 Model Selection InformationFollowing model numbers are for 120 SizeDescriptionModel Number1/4" NPTBase MountedCJ125013/8" NPTBase MountedCJ13701 Port SizeDescriptionModel Number1/4" NPTWall MountedCWJ125013/8" NPTWall MountedCWJ137010B0 ANormally OpenNormally ClosedAB0B0 ANormally OpenNormally ClosedAB4 C/CW Series Valves3-Way, 2-PositionCatalog 0640-E/USAS ingle Solenoid & Remote PressureParker Hannifin CorporationPneumatic DivisionRichland, 3-Way, 2-Position , cam operated spool Valves are used tooperate single acting cylinders.

6 They can be usedas normally closed or normally open, and as a for inline use. Use C Series for mounting to horizontalsurfaces. Use CW Series for mounting to vertical or Spring Returned position of the spool Pressure at inlet port A is blocked and port 0 is connected toport B . When ball is activated, port A is connected to port 0 and port B is blocked. Because of the area-balancedconstruction of the spool , either port A or port B may be usedas the inlet supply port. Pressure to port A valve is normallyclosed valve. Pressure to port B is normally open 3-Way, 2-Position , double remote pressure operatedspool Valves are used to operate single acting cylinders. Theycan be used as normally closed or normally open,and as a for inline use. Use C Series for mounting tohorizontal surfaces. Use CW Series for mounting to pressure is applied to port 2 last, pressure at inlet port A is blocked and port 0 is connected to port B.

7 Whenpressure is applied to port 1 last, port A is connected to port 0 and port B is blocked. Because of the area-balancedconstruction of the spool , either port A or port B may be usedas the inlet supply port. Pressure to port A valve is normallyclosed valve. Pressure to port B valve is normally open Selection InformationPort SizeDescriptionModel Number1/4" NPTBase Mounted, Ball CamC2253/8" NPTBase Mounted, Ball CamC237 Port SizeDescriptionModel Number1/4" NPTWall Mounted, Ball CamCW2253/8" NPTWall Mounted, Ball CamCW237 Model Selection InformationPort SizeDescriptionModel Number1/4" NPTBase MountedC12253/8" NPTBase MountedC1237 Port SizeDescriptionModel Number1/4" NPTWall MountedCW12253/8" NPTWall MountedCW12370B0 ANormally OpenNormally ClosedAB0B0 ANormally OpenNormally Closed#2 OperatorEnd#1 OperatorEnd#1 OperatorEnd#2 OperatorEndAB5 C/CW Series Valves3-Way, 2-PositionCatalog 0640-E/USAD ouble Remote Pressure & Cam OperatedParker Hannifin CorporationPneumatic DivisionRichland, & CW94 Heavy DutyC92 & CW92 Overriding CamApplicationThese 3-Way, 2-Position , cam operated spool Valves are usedto operate single acting cylinders.

8 They can be usedas normally closed or normally open, and as a for inline use. Use C Series for mounting tohorizontal surfaces. Use CW Series for mounting to or Spring Returned position of the spool Pressure at inlet port A is blocked and port 0 is connected toport B . When cam is activated, port A is connected to port 0 and port B is blocked. Because of the area-balancedconstruction of the spool , either port A or port B may be usedas the inlet supply port. Pressure to port A valve is normallyclosed valve. Pressure to port B is normally open and CW92 are overriding cams which operate in onedirection 3-Way, 2-Position , cam operated spool Valves are usedto operate single acting cylinders. They can be usedas normally closed or normally open, and as a for inline use. Use C Series for mounting tohorizontal surfaces. Use CW Series for mounting to or Spring Returned position of the spool Pressure at inlet port A is blocked and port 0 is connected toport B.

9 When cam is activated, port A is connected to port 0 and port B is blocked. Because of the area-balancedconstruction of the spool , either port A or port B may be usedas the inlet supply port. Pressure to port A valve is normallyclosed valve. Pressure to port B valve is normally open and CW94 operate from either Selection InformationPort SizeDescriptionModel Number1/4" NPTBase Mounted, Heavy Duty,C9225 Overriding Roller Lever3/8" NPTBase Mounted, Heavy Duty,C9237 Overriding Roller LeverPort SizeDescriptionModel Number1/4" NPTWall Mounted, Heavy Duty,CW9225 Overriding Roller Lever3/8" NPTWall Mounted, Heavy Duty,CW9237 Overriding Roller LeverModel Selection InformationPort SizeDescriptionModel Number1/4" NPTBase Mounted, Heavy Duty,C9425 Roller Lever3/8" NPTBase Mounted, Heavy Duty,C9437 Roller LeverPort SizeDescriptionModel Number1/4" NPTWall Mounted, Heavy Duty,CW9425 Roller Lever3/8" NPTWall Mounted, Heavy Duty,CW9437 Roller Lever0B0 ANormally OpenNormally ClosedAB0B0 ANormally OpenNormally ClosedAB6 C/CW Series Valves3-Way, 2-PositionCatalog 0640-E/USACam operated ValvesParker Hannifin CorporationPneumatic DivisionRichland.

10 & CW13 CamC9 & CW9 Overriding CamApplicationThese 3-Way, 2-Position , cam operated spool Valves are usedto operate single acting cylinders. They can be usedas normally closed or normally open, and as a for inline use. Use C Series for mounting tohorizontal surfaces. Use CW Series for mounting to or Spring Returned position of the spool Pressure at inlet port A is blocked and port 0 is connected toport B exhaust as a normally closed valve. Because of thearea-balanced construction of the spool , either port A or port B may be used as the inlet supply port. Pressure to port A valve is normally closed valve. Pressure to port B valve isnormally open 3-Way, 2-Position , cam operated spool Valves are usedto operate single acting cylinders. They can be usedas normally closed or normally open, and as a for inline use. Use C Series for mounting tohorizontal surfaces. Use CW Series for mounting to or Spring Returned position of the spool Pressure at inlet port A is blocked and port 0 is connected toport B exhaust as normally closed valve.


Related search queries