Air Control Valves P2 LAX 1/8". P2 LBX 1/4". P2 LCX 3/8". P2 LDX 1/2". Section H. H. Basic Valve H2 IEM Bar Manifolds, Assemblies & H10. Basic Valve H3 22mm Solenoid Pilot Operators & Solenoid Extreme Operation ATEX Complete Valve & Solenoid Pilot H13. Solenoid Common Part Numbers .. H4 Intrinsically Safe & Hazardous Duty H14. Solenoid Model Number Index .. H5 Technical H15. Remote Air Pilot Common Part H6 Electrical Connectors / Manual & Remote Air Pilot Model Number Index .. H7 Lever Operated Common Part H7 DOT Normal Operation Solenoid Common Part H8. Solenoid Model Number Index .. H9. BOLD ITEMS ARE MOST POPULAR. H1 Parker Hannifin Corporation Pneumatic Division Richland, Michigan Catalog 0600P-10/USA Viking Xtreme Series Valves Basic Valve Functions Air Control Valves Single Solenoid 4 2.

Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics H2 H 4 2 5 3 1 #14 #12 4 2 5 3 Sol 14 #12 4 2 5 3 1 #14#12 Double Solenoid

Tags:

  Control, Parker, Valves, Parker hannifin, Hannifin, Air control valves

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Air Control Valves - Parker Hannifin

1 Air Control Valves P2 LAX 1/8". P2 LBX 1/4". P2 LCX 3/8". P2 LDX 1/2". Section H. H. Basic Valve H2 IEM Bar Manifolds, Assemblies & H10. Basic Valve H3 22mm Solenoid Pilot Operators & Solenoid Extreme Operation ATEX Complete Valve & Solenoid Pilot H13. Solenoid Common Part Numbers .. H4 Intrinsically Safe & Hazardous Duty H14. Solenoid Model Number Index .. H5 Technical H15. Remote Air Pilot Common Part H6 Electrical Connectors / Manual & Remote Air Pilot Model Number Index .. H7 Lever Operated Common Part H7 DOT Normal Operation Solenoid Common Part H8. Solenoid Model Number Index .. H9. BOLD ITEMS ARE MOST POPULAR. H1 Parker Hannifin Corporation Pneumatic Division Richland, Michigan Catalog 0600P-10/USA Viking Xtreme Series Valves Basic Valve Functions Air Control Valves Single Solenoid 4 2.

2 Single Remote Pilot 4 2. Sol 14 #12 #14 #12. Single Pressure At Inlet Port 1: 5 3 Single Pressure At Inlet Port 1: 5 3. 1 1. De-energized position Solenoid operator #14 Normal position Pressure at inlet port 1 connected de-energized. Pressure at inlet port 1 connected to to outlet port 2. Outlet port 4 connected to exhaust port 5. outlet port 2. Outlet port 4 connected to exhaust port 5. Operated position Maintained air signal at port 14. Energized position Solenoid operator #14 energized. Pressure at inlet port 1 connected to outlet port 4. Pressure at inlet port 1 connected to outlet port 4. Outlet port 2 connected to exhaust port 3. Outlet port 2 connected to exhaust port 3. 4 2 4 2. Double Solenoid #14 #12. Double Remote Pilot #14 #12.

3 H Single Pressure At Inlet Port 1: 5. 1. 3 Single Pressure At Inlet Port 1: Momentary air signal at port 14 last. Pressure at inlet 5. 1. 3. Solenoid operator #14 energized last. Pressure at inlet port 1 connected to outlet port 4. Outlet port 2 connected port 1 connected to outlet port 4. Outlet port 2 connected to exhaust port 3. to exhaust port 3. Solenoid operator #12 energized last. Pressure at inlet Momentary air signal at port 12 last. Pressure at inlet port 1 connected to outlet port 2. Outlet port 4 connected port 1 connected to outlet port 2. Outlet port 4 connected to exhaust port 5. to exhaust port 5. 4 2 4 2 4 2 4 2. #14 #12 #14 #12 #14 #12 #14 #12. 5 3 5 3 5 3 5 3. 1 1 1 1. All Ports Blocked Center Exhaust All Ports Blocked Center Exhaust 4 2 4 2.

4 #14 #12 #14 #12. 5 3 5 3. 1 1. Pressure Center Pressure Center Double Solenoid Double Remote Pilot 3-Position 3-Position With #12 operator energized inlet port 1 connected to With #12 operator signaled inlet port 1 connected to cylinder port 2, cylinder port 4 connected to exhaust port 5. cylinder port 2, cylinder port 4 connected to exhaust port 5. With #14 operator energized inlet port 1 connected to With #14 operator signaled inlet port 1 connected to cylinder port 4, cylinder port 2 connected to exhaust port 3. cylinder port 4, cylinder port 2 connected to exhaust port 3. Closed Center Closed Center All ports blocked in the center position. All ports blocked in the center position. Vented Center Vented Center Cylinder ports 2 and 4 connected to exhaust ports 3 and 5 in Cylinder ports 2 and 4 connected to exhaust ports 3 and 5.

5 Center position. Port 1 is blocked. in center position. Port 1 is blocked. Pressurized Center Pressurized Center Pressure port 1 connected to cylinder ports 2 and 4, and Pressure port 1 connected to cylinder ports 2 and 4, and exhaust ports 3 and 5 blocked in center position. exhaust ports 3 and 5 blocked in center position. H2 Parker Hannifin Corporation Pneumatic Division Richland, Michigan Catalog 0600P-10/USA Viking Xtreme Series Valves Basic Valve Features Air Control Valves Specifications P2 LAX P2 LAX: Cv P2 LBX P2 LBX: Cv P2 LCX. P2 LCX: Cv P2 LDX P2 LDX: Cv P2 LAX. Double Solenoid, Inline, Materials of Construction 14 End Energized Valve Body: Anodized Aluminum Spool: Aluminum & Nitrile Rubber End Caps: Anodized Aluminum Coils: Thermoplastic Fasteners: Stainless Steel Operating Temperature H.

6 Normal: 14 F to 122 F. (-10 C to 50 C). P2 LBX. Extreme: -40 F to 158 F Double Solenoid, 3-Position APB. (-40 C to 70 C) Shown De-energized Operating Pressure Normal: Vacuum to 145 PSIG. (Vacuum to 10 bar). Extreme: Vacuum to 232 PSIG. (Vacuum to 16 bar). Ports P2 LAX. P2 LAX: 1/8" NPT & BSPP. P2 LBX P2 LBX: 1/4" NPT & BSPP. P2 LCX. P2 LCX. P2 LCX: 3/8" NPT & BSPP. Single Solenoid, Inline, Spring Return P2 LDX P2 LDX: 1/2" NPT & BSPP Shown De-energized Compliance / Approval IP65 Rated ATEX Option Available Solenoids to Watt Conduit, Grommet, 22mm & 30mm 3-Pin (DIN 43650), Hazardous Duty, Intrinsically Safe 12 VDC to 240 VAC. P2 LDX. Mounting Single Solenoid, Inline, Spring Return Inline Shown De-energized IEM Aluminum Bar Pressure Exhaust H3 Parker Hannifin Corporation Pneumatic Division Richland, Michigan Catalog 0600P-10/USA Viking Xtreme Series Valves Common Part Numbers Extreme Operating Pressure / Temperature Single Solenoid Double Solenoid 2-Position 2-Position 4 2 4 2.

7 Sol 14 #12 Sol. 14 Sol. 12. 5 3 51 3. 1. P2 LAX P2 LAX591 ESHDDB47 P2 LAX P2 LAX591 EEHDDB47. 12 VDC 12 VDC. P2 LAX591 ESHDDG47 P2 LAX591 EEHDDG47. Cv Cv P2 LAX591 ESHDDB48 P2 LAX591 EEHDDB48. 24 VDC 24 VDC. P2 LAX591 ESHDDG48 P2 LAX591 EEHDDG48. H P2 LBX P2 LBX592 ESHDDB47. P2 LBX592 ESHDDG47. 12 VDC. Cv P2 LBX P2 LBX592 EEHDDB47. P2 LBX592 EEHDDG47. 12 VDC. Cv P2 LBX592 ESHDDB48 P2 LBX592 EEHDDB48. 24 VDC 24 VDC. P2 LBX592 ESHDDG48 P2 LBX592 EEHDDG48. P2 LCX P2 LCX593 ESHDDB47 P2 LCX P2 LCX593 EEHDDB47. 12 VDC 12 VDC. P2 LCX593 ESHDDG47 P2 LCX593 EEHDDG47. Cv Cv P2 LCX593 ESHDDB48 P2 LCX593 EEHDDB48. 24 VDC 24 VDC. P2 LCX593 ESHDDG48 P2 LCX593 EEHDDG48. P2 LDX P2 LDX594 ESHDDB47 P2 LDX P2 LDX594 EEHDDB47. 12 VDC 12 VDC. P2 LDX594 ESHDDG47 P2 LDX594 EEHDDG47.

8 Cv Cv P2 LDX594 ESHDDB48 P2 LDX594 EEHDDB48. 24 VDC 24 VDC. P2 LDX594 ESHDDG48 P2 LDX594 EEHDDG48. Double Solenoid 3-Position All Ports Blocked 3-Position Center Exhaust All Ports Blocked Center Exhaust 4 2 4 2. Sol 14 Sol 12 Sol 14 Sol 12. 5 3 5 3. 1 1. All Ports Blocked Center Exhaust P2 LAX P2 LAX691 EEHDDG47 12 VDC P2 LAX P2 LAX891 EEHDDG47 12 VDC. Cv Cv P2 LAX691 EEHDDG48 24 VDC P2 LAX891 EEHDDG48 24 VDC. P2 LBX P2 LBX692 EEHDDG47 12 VDC P2 LBX P2 LBX892 EEHDDG47 12 VDC. Cv Cv P2 LBX692 EEHDDG48 24 VDC P2 LBX892 EEHDDG48 24 VDC. P2 LCX P2 LCX693 EEHDDG47 12 VDC P2 LCX P2 LCX893 EEHDDG47 12 VDC. Cv Cv P2 LCX693 EEHDDG48 24 VDC P2 LCX893 EEHDDG48 24 VDC. P2 LDX P2 LDX694 EEHDDG47 12 VDC P2 LDX P2 LDX894 EEHDDG47 12 VDC. Cv Cv P2 LDX694 EEHDDG48 24 VDC P2 LDX894 EEHDDG48 24 VDC.

9 NOTE: See Page H5 for Valve Description. H4 Parker Hannifin Corporation Pneumatic Division Richland, Michigan Catalog 0600P-10/USA (Revised 12-07-07) Viking Xtreme Series Valves Model Number Index Extreme Operating Pressure / Temperature Single & Double Solenoid Operated Valves Vacuum to 232 PSIG (Vacuum to 16 bar). -40 F to 158 F (-40 C to 70 C). P2L A X 5 91 E S H D D G 47. Valve Size Voltage / Frequency 1/8" A 42 24 VAC. 1/4" B 45 12 VDC. 3/8" C* 47* 12 VDC Mobile 1/2" D* 48* 24 VDC Mobile * See Note Below for Pressure rating. 49 24 VDC. 53 120 VAC. Valve Type / Function 57 240 VAC. Blank Valve Less Coil H. Internal Pilot Supply to Solenoid * Only Available with Enclosures A , B & G . 2-Position Valve 5. Additional voltages are available upon request.

10 3-Position Valve APB 6 Contact Customer Support for more information. 3-Position Valve PC 7. 3-Position Valve CE 8 Enclosures / Lead Length External Pilot Supply to Solenoids through Ports #12 & #14. 30mm Square 3-Pin ISO 4400. 2-Position Valve N A. Form A (Male Only). 3-Position Valve APB P 22mm Rectangular 3-Pin Type B. B. 3-Position Valve PC Q Industrial (Male Only). 3-Position Valve CE R G Grommet - 18" Leads H 1/2" NPT Conduit - 18" Leads N Solenoid Pilot Operator Less Coil Main Port Thread G1/8 (P2LA) 11. Overrides G1/4 (P2LB) 12 D Extended, Non-Locking G3/8 (P2LC) 13 A No Override G1/2 (P2LD) 14 H Heavy Duty, Locking 1/8" NPT (P2LA) 91. 1/4" NPT (P2LB) 92 Solenoid Pilot Type 3/8" NPT (P2LC) 93 D Vented Pilot Exhaust 1/2" NPT (P2LD) 94 N Tapped Pilot Exhaust (M5).