All Button and OneTouch Control Systems …

All Button and OneTouchControl Systems installation ManualPool/Spa Combination Systemsand Pool/Spa Only SystemsTable of ContentsSafety Safety Information .. 4 system and Center Mounting .. Voltage system Power .. 3HP Relay (filter pump) .. Underwater Voltage Wiring .. Connecting the Power Center Bezel .. Controller Cable to Power Center PCB .. Gas Heater Connections .. Sensor Connections .. Jandy Valve Actuators .. Auxiliary Power Centers .. All Button Indoor Control Panels.

All Button and OneTouch Control Systems ™ Installation Manual Pool/Spa Combination Systems and Pool/Spa Only Systems

Tags:

  Manual, System, Installation, Control, Onetouch, And onetouch control systems, And onetouch control systems installation manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of All Button and OneTouch Control Systems …

1 All Button and OneTouchControl Systems installation ManualPool/Spa Combination Systemsand Pool/Spa Only SystemsTable of ContentsSafety Safety Information .. 4 system and Center Mounting .. Voltage system Power .. 3HP Relay (filter pump) .. Underwater Voltage Wiring .. Connecting the Power Center Bezel .. Controller Cable to Power Center PCB .. Gas Heater Connections .. Sensor Connections .. Jandy Valve Actuators .. Auxiliary Power Centers .. All Button Indoor Control Panels.

2 OneTouch Indoor Control Panels .. Wireless OneTouch Indoor Control Panels .. 22 system Button Button Reset and Display Messages .. OneTouch Programming .. OneTouch Reset and Display Messages .. Button and OneTouch system Defaults and General Modes .. Button Menu Flow Chart .. Button Cancel Button Flow Chart .. Menu Flow Chart .. Troubleshooting Wireless Quick Troubleshooting Guide .. Center Wiring Diagram .. Center DIP Switch Settings .. , Water Feature and Light Label Menus .. Information .. 404 Jandy AquaLink RSSafety Safety AND FOLLOW ALL la notice To reduce the risk of injury, do not permit children to usethis product unless they are closely supervised at all All electrical work must be performed by a licensed electrician and must conform toall national, state, and local Water temperature in excess of 100 F/38 C may beinjurious to your :Des Temp ratures de l'eau sup rieures 38 C/100 F peuvent pr senter un danger pour la sant.

3 Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurswhen the internal temperature of the body reaches a level several degrees abovethe normal body temperature of F. The symptoms include dizziness, fainting,drowsiness, lethargy, and an increase in the internal temperature of the body. Theeffects of hyperthermia include unawareness of impending danger, failure toperceive heat, failure to recognize the need to exit the spa, physical inability to exitthe spa, fetal damage in pregnant women, and unconsciousness resulting in adanger of The use of alcohol.

4 Drugs or medication can greatlyincrease the risk of fatal hyperthermia in hot tubs & consommation d'alcool ou de drogue augmenteconsid rablement les risques d'hyperthermie mortelledans une cuve de to provide drainage of compartment for electrical Install the Power Center at least five (5) feet ( ) from the inside wall of thepool and/or hot tub. Canadian installations must be at least three (3) meters fromthe water. Les installations Canadiennes doivent se trouver au moins trois (3)m tres de l A ground-fault circuit-interrupter must be provided if this device is used to controlunderwater lighting fixtures.

5 The conductors on the load side of the ground-faultcircuit-interrupter shall not occupy conduit, boxes, or enclosures containing otherconductors unless the additional conductors are also protected by a ground-faultcircuit-interrupter. Refer to local codes for complete A terminal bar marked GROUND is provided within the Power Center. To reducethe risk of electrical shock, connect this terminal bar to the grounding terminal ofyour electric service or supply panel with a continuous green insulated copper wireequivalent in size to the circuit conductors supplying this equipment, but no smallerthan No.

6 12 AWG ( ). In addition, a second wire connector should be bondedwith a No. 8 AWG ( ) copper wire to any metal ladders, water pipes, orother metal within five (5) feet ( ) of the system IS INTENDED TO Control HEATERS WITH BUILT-INHIGH LIMIT CIRCUITS SAVE THESE Controls5 system ContentsPackage contents will depend on which AquaLink RS system you are installing. All JandyAquaLink RS Systems come complete with the appropriate number of 3HP relays Button Control Panel,Power Center PCB,Two (2) Temp Sensors,Additional Relays,Two (2) JVAs (Pool/Spa Combo Systems ) OneTouch Control Panel,Power Center PCB,Two (2) Temp Sensors,Additional Relays,Two (2) JVAs (Pool/Spa Combo Systems )Standard Power Center(with mounting brackets)Wireless OneTouch Control Panel,Outdoor Transceiver J-box,Power Center PCB,Two (2) Temp Sensors,Additional Relays,Two (2)

7 JVAsControl system Sub-AssembliesPower CentersAll ButtonOneTouchWireless OneTouchSub-Panel Power Center(with mounting brackets)6 Jandy AquaLink RSSystem Component Specifications and DimensionsSpecifications (USA and Canada):Power Supply:120 VAC; 60 Hz; 3 AContact Rating:High voltage - 25 A; 3HP @ 240 VAC1 HP @120 VAC1500 Watts IncandescentLow Voltage - Class Two, 1 A @ 24 VACE mergencyService Switch:All Circuits (located at Power Center in Service Mode)Specifications (European):Power Supply:230-240 VAC; 50/60 Hz; 3 AContact Rating:High voltage - 25 A; 3HP @ 240 VACLow Voltage - Class Two, 1 A @ 24 VACE mergencyService Switch:All Circuits (located at Power Center in Service Mode)Dimensions:StandardPowerCenter5"14 "13 "8"5"1 "5 "1 "5"4 "4 "1 "Sub-PanelPowerCenter20"14 "5"All ButtonControl PanelOneTouchControl PanelWirelessControl PanelJandy Controls7 Plumbing for Pool and Spa CombinationSystem is a simplified version of a standard plumbing setup for a pool and spa that share thesame filter pump, filter, and heater.

8 The intake and return JVA s turn simultaneously so whenthe Spa Button is pressed on the AquaLink RS Control Panel, water circulation switchesbetween pool and spa (consult the Jandy JVA installation manual to ensure that the JVA sare "in sync" and rotate properly). Please consult the Jandy Valve Plumbing manual forfurther examples of pool/spa note that if you have a pool only or a spa only, the diagram does not apply, and if yourpool and spa have separate sets of equipment, you should install an AquaLink RS DualEquipment model, designed to Control separate equipment.

9 When the filter system is shared (a Pool/Spa Combo), the spa water must be able tooverflow back to the DrainSpa DrainSpa ReturnPool ReturnCheckValveSpaMake-upCheckValveHeat PumpSkimmersSkimmersFrom SolarTo Solar8 Jandy AquaLink RSNon-Booster Pump Pool Cleaner PlumbingSystem OverviewHeaterFilterFilterPumpPool IntakeSpa IntakeSpa ReturnPool ReturnCheckValveSpa Make-upEnergyFilterCleanerLineBooster Pump Pool Cleaner PlumbingHeaterFilterFilterPumpPool IntakeSpa IntakeSpa ReturnPool ReturnCheckValveSpa Make-upBoosterPumpJandy Center Power Center should be located at or near the equipment pad.

10 Locate the Power Center atleast five (5) feet or more away from pool/spa and five (5) feet off the ground. All national,state, and local codes are the mounting brackets and instructions provided with the Standard Power Center and/orSub-Panel Power Power Centers have special code requirements. Be sure to follow all applicablelocal and state codes to insure safe Voltage Power- Depending on the amount of equipment being controlled, run " or "conduit from the power supply panel to the bottom of the Power Center. If you are usingthe Sub-Panel Power Center, wire power to the appropriate breakers.