ALL CONTROLS

FLAME SAFEGUARDS SECTION 6 SECTION 6 SECTION 6 SECTION 6 SECTION 6 DETECTORSBURNER CONTROLSBURNER CONTROL / SEMI AUTOMATICRE384-510 SeriesIFWLFE10 BrahmaCrouzetKromschroderLandis & StfaBURNER CONTROL WITH INTEGRAL HSI IGNITOR /SENSOR50 A 72, 768GH4 MWhite RodgersRamBURNER CONTROL WITH INTEGRAL IGNITIONCE, CM, SM, MM, AT53EM, 5 EMBrahmaRamPROGRAMMING CONTROLS FOR GAS BURNERSMPI 370 / 440 / 460 / 480,IFS, MPT, PFDKG, , DMG, MMI,MMG, TMGB rahmaCrouzetKromschroderSatronicLandis & StfaSENSOR - UVUV1, FD1, SeriesUV SeriesQRAUVUVZ, UVDB rahmaCrouzetKromschroderLandis & StfaPactrolSatronicSENSOR - IONIZATIONPSECastINDUSTRIAL UV CELL HOLDERSCEALL CONTROLS6 - CONTROLSPh: (08) 9277 4299 Fax: (08) 9277 5824083Z3050 LFE 10 CONTROL - LANDIS & STAEFA Plug in Base UV Cell - Series QRA* or Flame Rod Sensing Electrical Open Contact Electrical Closed Contact 240 or 110

6 - 5 www.allcontrols.com.au ALL CONTROLS Ph: (08) 9277 4299 Fax: (08) 9277 5824 083RAM0160 083RAM0165 5EM 7 -01 CONTROL - RAM Same features and approval as the 5EM 10 -01 but has

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of ALL CONTROLS

1 FLAME SAFEGUARDS SECTION 6 SECTION 6 SECTION 6 SECTION 6 SECTION 6 DETECTORSBURNER CONTROLSBURNER CONTROL / SEMI AUTOMATICRE384-510 SeriesIFWLFE10 BrahmaCrouzetKromschroderLandis & StfaBURNER CONTROL WITH INTEGRAL HSI IGNITOR /SENSOR50 A 72, 768GH4 MWhite RodgersRamBURNER CONTROL WITH INTEGRAL IGNITIONCE, CM, SM, MM, AT53EM, 5 EMBrahmaRamPROGRAMMING CONTROLS FOR GAS BURNERSMPI 370 / 440 / 460 / 480,IFS, MPT, PFDKG, , DMG, MMI,MMG, TMGB rahmaCrouzetKromschroderSatronicLandis & StfaSENSOR - UVUV1, FD1, SeriesUV SeriesQRAUVUVZ, UVDB rahmaCrouzetKromschroderLandis & StfaPactrolSatronicSENSOR - IONIZATIONPSECastINDUSTRIAL UV CELL HOLDERSCEALL CONTROLS6 - CONTROLSPh: (08) 9277 4299 Fax.

2 (08) 9277 5824083Z3050 LFE 10 CONTROL - LANDIS & STAEFA Plug in Base UV Cell - Series QRA* or Flame Rod Sensing Electrical Open Contact Electrical Closed Contact 240 or 110 volt AC AGA Approved Number 5517 Class 3D083KR28162 IFW15 CONTROL - KROMSCHRODER Plug in Base UV Cell - Series UVS* or Flame Rod Sensing Amber Light - Flame On Electrical Open Contact Electrical Closed Contact 240 or 110 volt AC AGA Approved Number 4131 Class 3D083C3350884-510-508 CONTROL - CROUZET Plug in Base UV Cell - Type or Flame Rod Sensing Yellow Flashing Light - Flame On Two Electrical Change-over Contacts 240 volt AC AGA Approved Number 6324 Class 3D083B1115083B1190RE 3 CONTROL - BRAHMA Plug in Base UV Cell or Flame Rod Sensing Green Light - Power On Red Light - Flame On Two Electrical Change-over Contacts 240

3 Or 110 volt AC AGA Approved Number 5367 Class 3 DUV 1 BRAHMA UV DetectorBBBBBURNER CONTROL / SEMI AURNER CONTROL / SEMI AURNER CONTROL / SEMI AURNER CONTROL / SEMI AURNER CONTROL / SEMI AUTUTUTUTUTOMAOMAOMAOMAOMATICTICTICTICTI C6 - CONTROLSPh: (08) 9277 4299 Fax: (08) 9277 5824083B1150083B1154CE11 U MICROFLAT - BRAHMA Restart Attempt Plug in Electrical Connections Single Gas Valve Volatile Lock-out Pre-Purge sec Flame Failure Safety Time - 5 or 10 sec Ionization flame electrode control 240 or 110 volt AC AGA Approved Number 5391 Class 2 CbCE12 U MICROFLAT - BRAHMASame features and approval as CE11 U but has Pilot / Main Gas (2 Valves)BBBBBURNER CONTROL WITH INTEGRAL CONTROL WITH INTEGRAL CONTROL WITH INTEGRAL CONTROL WITH INTEGRAL CONTROL WITH INTEGRAL CONTROL WITH INTEGRAL IGNITIONURNER CONTROL WITH INTEGRAL IGNITIONURNER CONTROL WITH INTEGRAL IGNITIONURNER CONTROL WITH INTEGRAL IGNITIONURNER CONTROL WITH INTEGRAL IGNITION083W0420401 IGNITOR - NORTON Silicon Carbide 24 volt ACOTHER VERSIONS AVAILABLE083 RAM0210083 RAM0255083 RAM0215H4M7-01 CONTROL - RAM Plug in Electrical Connectors Re-Start Attempt Single Gas Valve Volatile Lock - Out Flame Sensor Hot Surface Ignitor Flame Failure Safety Time - 5 sec LED Diagnostics 24 volt AC AGA Approved Number 5522 Class 2 CbH4M7-02 RAM CONTROLSame features and approval as the H4M7-01 but has Pilot & Main Gas Valves Air pressure circuit / lock outH4M C9-01 RAM CONTROLAll

4 The same features as the H4M7-01 but has Air Pressure Proving / Fan AGA Approved Number 5522 Class 2Ca083W02**50A72-2** CONTROL - WHITE RODGERS Plug in Connectors Re-Start Attempt Single Gas Valve Flame Sensor Hot Surface Ignitor LED Indicator 240 volt AC AGA Approved Number 5431 Class 2Cb083W04**768G-214 WHITE RODGERS IGNITOR/SENSOR Silicon Nitride 240 volt6 - CONTROLSPh: (08) 9277 4299 Fax: (08) 9277 5824 BBBBBURNER CONTROL WITH INTEGRAL IGNITION CONTROL WITH INTEGRAL IGNITION CONTROL WITH INTEGRAL IGNITION CONTROL WITH INTEGRAL IGNITION CONTROL WITH INTEGRAL IGNITION EUROFLAT - BRAHMA Plug-in Electrical Connections Re-Start Attempt Pilot & Main Gas Valves Volatile Lock-out Pre-Purge - 5 sec or 30 sec Fan Control with Air Pressure Proving Flame Failure Safety Time - 5 sec Ionization Flame Electrode Control 240 or 110 volt AC AGA Approved Number 5390 Class 2 CaCM32 EUROFLAT - BRAHMASame features and approval the CE32 but has Non Volatile Lockout Remote Flame Failure Reset083B1156083B1152083B1154083B1156CE3 1 U MICROFLAT - BRAHMASame features as CE11 U but has Air Pressure Proving / Fan AGA Approved Number 5391 Class 2 CaCM11 U MICROFLAT - BRAHMASame feature and

5 Approval as CE11 U but has Remote Flame Failure Reset Push Button Non Volatile LockoutCM12 U MICROFLAT - BRAHMASame features and approval CM11 U but has Pilot / Main Gas (2 Valves) Non volatileCM31 U MICROFLAT - BRAHMASame features and approval as CE31 U but has Remote Flame Failure Reset Push Button Non Volatile Lockout083B1181SM192 EUROBOX - BRAHMA Plug-in Base Re-Start Attempt Pilot / Main Gas (2 Valves) Manual Reset Pre-Purge - 5 sec Flame Failure Safety Time - 5 sec Ionization Flame Electrode Control 240 or 110 volt AC AGA Approved Number 5380 Class 2Cb6 - CONTROLSPh: (08) 9277 4299 Fax: (08) 9277 5824083 RAM0112083 RAM0115083 RAM01203EM 10 - 07 CONTROL - RAM Plug in Electrical Connectors Re-Start Attempt Single Valves Volatile Lock-out Single Sensor Ionization / Ignition Flame Failure Safety Time - 5 sec LED Operation Indication Diagnostics 24 volt AC AGA Approved Number 5522 Class 2 CbWiring Kit available - RAM0112KD3EM C10 -04 CONTROL - RAMSame features as the 3EM 10 -04 but has Fan Control with Air Pressure Proving AGA Approved Number 5522 Class 2Ca3EM C7-04 CONTROL - RAMSame features & approval as the 3EM C10-04but has Double SensorBBBBBURNER CONTROL WITH INTEGRAL IGNITION URNER CONTROL WITH INTEGRAL IGNITION URNER CONTROL WITH INTEGRAL IGNITION URNER CONTROL WITH INTEGRAL IGNITION URNER CONTROL WITH INTEGRAL IGNITION CONTROL - BRAHMA Plug in Base Pilot / 2 Main Gas Valves

6 Manual Reset Pre-Purge 15 sec Flame Failure Safety Time - 10 sec Ionization Flame Electrode Control 240 or 110 volt AC AGA Approved Number 3195 Class 2Ca083B1184083B1188CM391 EUROBOX - BRAHMASame features as the SM192 but has Fan Control with Air Pressure Proving AGA Approval Number 5380 Class 2 CaMM192 EUROBOX - BRAHMASame features and approval as SM192 but has Single Flame Rod / Ignition Control Remote Reset6 - CONTROLSPh: (08) 9277 4299 Fax: (08) 9277 5824083 RAM0160083 RAM01655EM 7 -01 CONTROL - RAMSame features and approval as the 5EM 10 -01 but has Seperate Sensor5EM C7 -01 CONTROL - RAMSame features as the 5EM 7 -01 but has Fan Control with Air Pressure Proving AGA Approved Number 5522 Class 2 CaWiring kits available - RAM0160K083 RAM01555EM 10 -01 CONTROL - RAM Plug in Electrical Connector Restart Attempt Pilot / Main Valves Volatile Lockout Single Sensor Ionization / Ignitor Flame Failure Safety Time - 5 sec Operation 24 volt AC AGA Approved Number 5522 Class 2 CbBBBBBURNER CONTROL WITH INTEGRAL IGNITION URNER CONTROL WITH INTEGRAL IGNITION URNER CONTROL WITH INTEGRAL IGNITION URNER CONTROL WITH INTEGRAL IGNITION URNER CONTROL WITH INTEGRAL IGNITION Cell - CROUZET083KR28258 BCU 370 - KROMSCHRODER Plastic case Pilot

7 / Main gas valve Remote reset UV cell or ionization control Restart or immediate lock-out Programmed by external computer Optional field bus interfaceAGA Approval: Awaiting6 - CONTROLSPh: (08) 9277 4299 Fax: (08) 9277 5824 PROGRAMMING CONTROLPROGRAMMING CONTROLPROGRAMMING CONTROLPROGRAMMING CONTROLPROGRAMMING CONTROLS FOR GS FOR GS FOR GS FOR GS FOR GAS BAS BAS BAS BAS BURNERSURNERSURNERSURNERSURNERS 258 CONTROL - KROMSCHRODER Plug in base 1 Valve connection Remote reset UV cell or ionization control Restart or immediate lock-out 110 / 240 volt AC Indicator lights AGA Approval Number 4230083KR2830 BCU 440 / 460 / 480 - KROMSCHRODER Metal case Pilot / Main gas valve Remote reset UV cell or ionization control Restart or immediate lock-out Programmed by external computer Optional field bus interface Optional pressuring provingAGA Approval.

8 Awaiting083B130010 MPI - BRAHMA Plug in base Pilot / Main gas valve Remote Reset UV cell or ionization control Restart or immediate lock-out Microprocessor based Optional pressuring provingAGA Approval: 71686 - CONTROLSPh: (08) 9277 4299 Fax: (08) 9277 5824 PFS KROMSCHRODER CONTROLPFD KROMSCHRODER CONTINUOUS CONTROLPFF FLAME DETECTION 4 BURNERSPFR RELAY CONTROL 4 BURNERSPFP POWER SUPPLY 24v DC 19 Rack System 240 or 110 volt AC AGA Approved Number 5597 Class 2A083KR28024083KR4010083KR4030 IFS135B CONTROL - KROMSCHRODER Plug in Base Pilot / Main Gas Valves Remote Reset / Flame Failure Indicator Pre-Purge 3 sec Flame Failure Safety Time 5 sec UV Cell or Ionization Control 240 volt AC AGA Approved Number 3949 Class 2 BUVS1 Heat Protective Housing - KROMSCHRODERUVS 6 Heat Protective Housing - KROMSCHRODERMPT 700 - KROMSCHRODER Pulse firing controller 95 - 240v 1 or 2 zones 1 to 8 burners Multiple programs083KR28084083KR4020 IFS110 - IM CONTROL - KROMSCHRODER Plug in Base Pilot / Main Gas Valves

9 Remote Reset / Flame Failure Indicator Pre-Purge 5 sec Flame Failure Safety Time 5 sec Single Electrode / UV Cell 240 or 110 volt AC AGA Approved Number 4230 Class 2 BUV5 UV CellPROGRAMMING CONTROLPROGRAMMING CONTROLPROGRAMMING CONTROLPROGRAMMING CONTROLPROGRAMMING CONTROLS FOR GS FOR GS FOR GS FOR GS FOR GAS BAS BAS BAS BAS BURNERS - CONTROLSPh: (08) 9277 4299 Fax: (08) 9277 5824 PROGRAMMING CONTROLPROGRAMMING CONTROLPROGRAMMING CONTROLPROGRAMMING CONTROLPROGRAMMING CONTROLS FOR GS FOR GS FOR GS FOR GS FOR GAS BAS BAS BAS BAS BURNERS 972 MOD 5 - SATRONICM icroprocessor Atmospheric Control Plug in base Pilot / Main gas valve Remote reset / Flame failure indicator Flame failure safety time - 5 sec UV cell or ionization control 240 volt AC AGA Approved Number 6018 Class 2Ca083SA0350003 DMG 970-03 - SATRONICM icroprocessor Gas Burner Control Plug in base Pilot / Main gas valve Remote reset / Flame failure indicator Pre-Purge - 40 sec Flame failure safety time - 3 sec UV cell or ionization control 240 volt AC AGA Approved Number 6039 Class - SATRONICM icroprocessor Oil Burner Control Suitable for the control & monitoring of oil Power burners up to 30kg/hr

10 Capacity 2 stage operation UV cell or ionization control Pre - purge 12 seconds Post ignition time 2 - 5 seconds Manual reset from lockout 240 volt AC6 - CONTROLSPh: (08) 9277 4299 Fax: (08) 9277 5824083SA0622520083SA0640320083SA0642120 MMI MOD 45 - SATRONICMMG MOD 45 - SATRONICMMG MOD 65 - SATRONICS ynchronous Motor Gas Burner Control Plug in base Pilot / Main gas valve Remote reset / Flame failure indicator Pre-Purge - 40 sec or 65 sec Flame failure safety time - 5 sec UV cell or ionization control 240 volt AC AGA Approved Number 3749 Class 2 APROGRAMMING CONTROLPROGRAMMING CONTROLPROGRAMMING CONTROLPROGRAMMING CONTROLPROGRAMMING CONTROLS FOR GS FOR GS FOR GS FOR GS FOR GAS BAS BAS BAS BAS BURNERS 740-3 MOD 43-35 - SATRONICS ynchronous Motor Programme Gas Burner Control Plug in base Pilot / Main gas valve Remote reset / Flame failure indicator Pre-Purge - 32 sec or 60 sec Flame failure safety time - 5 sec UV cell or ionization control 240 volt AC AGA