DINUSDINDINUSDIN cyan yellow magenta S GOLDEN EDITION V T CTechnical DataALLROUNDER 270/320 CTie bar distances: 270 x 270 mm, 320 x 320 mmClamping forces: 300, 400, 500, 600 kNInjection units (according to euromap ): 100, 250 DINUSDINDINUSDIN cyan yellow magenta keyUSUS270/320 CMachine dimensions1) Dimensions apply for 270 C 500-250 320 C 600-2502) Dimension only valid in conjunction with conveyor beltmin. 210max. 385cooling water connectionselectrical connectioncooling water supply line DN 25 max. 25 C min. 4 barcooling water return line DN 25electrical connection51536551)805330117016051206405 0021901200215 / 4402)19902553806408201210R39014751425695 34202 DINUSDINDINUSDIN cyan yellow magenta keyUSUS270/320 CTechnical dataMachine modelEUROMAP size indication1)Clamping unitClamping force max. kNClosing force max. kNOpening force / increased max.

DIN US DIN DIN US DIN cyan yellow magenta key US US Technical data 270/320 C Machine model EUROMAP size indication1) Clamping unit Clamping force max. kN

Tags:

  Technical, Euromap, Allrounder, Allrounder 270 320 c technical

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ALLROUNDER 270/320 C Technical Data - w.plompen

1 DINUSDINDINUSDIN cyan yellow magenta S GOLDEN EDITION V T CTechnical DataALLROUNDER 270/320 CTie bar distances: 270 x 270 mm, 320 x 320 mmClamping forces: 300, 400, 500, 600 kNInjection units (according to euromap ): 100, 250 DINUSDINDINUSDIN cyan yellow magenta keyUSUS270/320 CMachine dimensions1) Dimensions apply for 270 C 500-250 320 C 600-2502) Dimension only valid in conjunction with conveyor beltmin. 210max. 385cooling water connectionselectrical connectioncooling water supply line DN 25 max. 25 C min. 4 barcooling water return line DN 25electrical connection51536551)805330117016051206405 0021901200215 / 4402)19902553806408201210R39014751425695 34202 DINUSDINDINUSDIN cyan yellow magenta keyUSUS270/320 CTechnical dataMachine modelEUROMAP size indication1)Clamping unitClamping force max. kNClosing force max. kNOpening force / increased max.

2 KNOpening stroke max. mmMould height min. mmDaylight max. mmDistance between tie bars mmPlaten size (hor. x vert.) mmWeight of mov. mould half6) max. kgEjector force max. kNEjector stroke max. mmHydraulics, drive, generalDrive power of the hydraulic pump kWDry cycle time for opening stroke3) s-mmTotal connected load2) kWColour: plastic coated, structure light grey / mint green / canary yellowControl cabinetSafety standard according to Socket combination (1 single phase, 1 three-phase)Injection unitScrew diameter mmEffective screw length L/DScrew stroke max. mmCalculated injection volume max. cm3 Shot weight max. g PSMaterial throughput5) max. kg/h PS max. kg/h PA pressure4) max. barInjection flow4) max. cm3/s Injection flow with accumulator max. cm3/sBack pressure positive / negative max. barCircumferential screw speed max. m/minScrew torque max. NmNozzle contact force max.

3 KNNozzle retraction stroke max. mmInstalled cylinder heating power / heating zones kWInstalled nozzle heating power kWMaterial hopper capacity lHorizontal injection position max. mmMachine dimensions and weights of the basic machineOil capacity lNet weight kgElectrical connection (pre-fused)2) A1) 1st figure: clamping force (kN), 2nd figure: max. dosage volume (cm3) x max. injection pressure (kbar)2) Values refer to 400 V/50 Hz. The load is symmetrically distributed on three phases (observe phase loading when installing new equipment)3) According to euromap for the basic machine. Values shown in parentheses apply for dual-pump technology, basic equipment version with 600 kN clamping ) A combination of max. injection pressure and max injection flow (max. injection capacity) can be mutually exclusive, depending on the equipment-related motor output5) Deviations are possible depending upon process settings and material type6) Values shown in parentheses apply with optional support of the movable mould platenThese Technical data specifications refer to the state at the time of printing.

4 We reserve the right to modify specifications in the interest of a continuous program of further C300-1003003525 / 130350200550270 x 270446 x 446180 (270)301257,51,3 (1,2)-18914,9 DIN EN 602041 x 16 A10020 / 25 / 3025 / 20 / 16,710031 / 49 / 7129 / 45 / 655,5 / 8 / 9,52,8 / 4 / 4,92500 / 2240 / 155056 / 88 / 128160 / 250 / 362350 / 20030 / 37 / 45120 / 150 / 180501804,3 / 40,650120160214050270 C400-1004003525 / 130350200550270 x 270446 x 446180 (270)30125111,3 (1,2)-18918,4 DIN EN 602041 x 16 A10020 / 25 / 3025 / 20 / 16,710031 / 49 / 7129 / 45 / 655,5 / 8 / 9,52,8 / 4 / 4,92500 / 2240 / 155056 / 88 / 128160 / 250 / 362350 / 20030 / 37 / 45120 / 150 / 180501804,3 / 40,650120160214063270 C500-2505003525 / 130350200550270 x 270446 x 446180 (270)30125151,1 (1,1)-18923,9 DIN EN 602041 x 16 A25030 / 35 / 4023,3 / 20 / 17,5150106 / 144 / 18897 / 132 / 17217 / 20,5 / 24,58,5 / 10,5 / 12,52470 / 1820 / 1390112 / 154 / 202350 / 476 / 622350 / 14049 / 57 / 66320 / 380 / 430602405,8 / 40,650120160223063320 C500-1005003525 / 130350200550320 x 320446 x 446180 (270)30125151,2 (1,2)-22422,4 DIN EN 602041 x 16 A10020 / 25 / 3025 / 20 / 16,710031 / 49 / 7129 / 45 / 655,5 / 8 / 9,52,8 / 4 / 4,92500 / 2240 / 155080 / 124 / 180160 / 250 / 362350 / 20042 / 52 / 63120 / 150 / 180501804,3 / 40,650120160216063320 C600-2506003525 / 130350200550320 x 320446 x 446180 (270)

5 30125151,2-22423,9 DIN EN 602041 x 16 A25030 / 35 / 4023,3 / 20 / 17,5150106 / 144 / 18897 / 132 / 17217 / 20,5 / 24,58,5 / 10,5 / 12,52470 / 1820 / 1390112 / 154 / 202350 / 476 / 622350 / 14049 / 57 / 66320 / 380 / 430602405,8 / 40,650120160233063 3 DINUSDINDINUSDIN cyan yellow magenta keyUSUS270/320 CEquipmentControl system and control cabinet SELOGICA control system (modu-lar, graphic multi-processor sys-tem) Available in different language versionsj Language change Cycle sequence programming with symbols Cycle step display in sequence diagramj Cycle time diagram Swivelling monitor unit, central on the operator s side, with col-our monitor Process graphics for injection speed, screw stroke and injection pressure Quality assurance program with fault evaluation and monitoring chart Optimisation and user help, fol-low-up functions at program end, for freely programmable parameter pages, selectable units Modular control cabinet design with self-recognition of plug in circuit board system Operating modes.

6 - Set up - Freely programmed test run - Reconfiguration - Automatic purging and dosingj Equipment for switch-over to holding pressure via injection pressure, material pressure with different pressure transducers, or via external switch over signal Data set administration via diskette Visual warning signal (warning lamp)j Visual / audible warning signal (flashing light / siren) Serial printer interface for hard copy, data record and quality protocolj Interfaces for: PC keyboard, plotter, robotic system according to euromap 12 or 67, part weighing scale, optical barrier, host processor, AQC, ALLROUNDER @web, colouring unit, LSR dosing system, INJESTER, container change, wiper unit (brush), THERMOLIFT, hot runner control unit and temperature control units for moulds and cylinder Socket combination 1 CEE, 1 Schuko 230 Vj Socket combination 1 CEE, 1 Schuko or 3 CEE, 3 Schuko 230 V with external supply linej 1 additional heating regulation circuit for the nozzlej Electric heating regulation circuits for moulds (adaptive) (3, 6, 9, 12, 15, 18).

7 Mould heating fused at 10 Aj Fuses for mould heating 16 Aj 4 or 8 freely programmable in-puts / outputsj Core pull programs in many ver-sions integrated in the SELOGICA control systemj Special processes such as injection coining, mould venting, variot-herm temperature control, intrud-ing, marblingj Monitoring: Freely-programmable position monitoringj Many individual options for special processesMachine base and hydraulic system Free standing machine base on anti-vibration pads Ergonomic protection cover with free access to mould and nozzle Space for peripheral devices within floor space The hydraulic system operates with an energy-saving variable displacement pump and a servo valve for pressure and speed regulationj Expansion to up to 2 hydraulic control circuitsj Expansion to up to 3 hydraulic control circuitsj ARBURG energy saving system AES (rpm changeable for hydrau-lic pump drive) Minimum oil volume, oil change interval every 20,000 hours Monitoring of oil level, oil tem-perature and oil filter contamina-tion Fine mesh oil filter in the return line Mechanical regulation of hydraulic oil temperature j Electronic regulation of hydraulic oil temperature.

8 Display and monitoring via screen Hydraulic oil preheating program to reduce start-up timej Separate, continuous oil circula-tion for additional cooling and filtration Manually adjustable, machine- related cooling water circuits with 4 free mould connectionsj 6 or 8 free cooling water circuits, manually adjustablej Programmable, machine and mould-related cooling water circuitsj 1 or 2 central switch-off valves for cooling waterj Conveyor belt (electrically driven), height-adjustable in 3 steps, can be integrated into the machine base with or without sorter unitj Crane with electric hoist to fa-cilitate mould installation and to swivel or shift the injection unitClamping unit Centrally applied, fully-hydraulic clamping system with 4 individu-ally-removable tie barsj Vertical support of the movable mould platensj Swivelling clamping unit, hydrau-lically activated (Technology stage 2) Movement profiles for the mould clamping unit are programmable and regulated.

9 They are serially driven using energy-saving one-circuit pump technology (Tech-nology stage 1)j Movement profiles for the mould clamping unit are programmable and regulated. They are driven us-ing two-circuit pump technology (Technology stage 2 - servo-regu-lated). The closing pressure is reg-ulated. Simultaneous movement of nozzle and ejector is possiblej Hydraulic system with 3 regulat-ing pumps for extended simulta-neous movements (T3) Closing and opening profiles are 2-stage programmable (4-stage with Technology stage 2)j Intermediate stop possible when closing and opening (standard with T2) Regulated hydraulic mould pro-tection with monitoring of mould protection time. Follow-up func-tions: Open or stop after 1 or 2 activations of mould protectionj Extended mould protection ( for spring loaded moulds). Freely-programmable start and end Automatic ramp control during switch-over to a lower speed and during stopping of a movement function Hydraulic ejector with quick re-lease coupling is integrated into the clamping system Hydraulic ejector: Forces and speeds, multiple stroke (up to 10) and ejector advanced at program end are programmablej Hydraulic ejector for simultane-ous movements regulated with servo valve Mould monitoring via ejector platen safety switchj Hydraulic core pulls with rapid connect coupling on the movable mould platenj Hydraulic core pull movement profiles programmable and regu-latedj Core holding pressure manually adjustable j Pressure hold programmablej Hydraulic core pull, simultaneous movements regulatedj Controlled hydraulic unscrewing units for threaded cores in one or two directions of rotation for mounting on fixed or movable clamping platen.

10 Restricted ejec-tor stroke4 DINUSDINDINUSDIN cyan yellow magenta keyUSUS270/320 CEquipmentj Unscrewing unit with electro- mechanical servo drive for 2-direction threaded cores for installation on the movable clamping platen for ultra-precise positioning and reproducibility. Restricted ejector stroke Attachment option for robotic handling devicej Mechanical rapid clamping sys-tem with mould support to facili-tate mould installationj Power-operated safety gate, programmable opening timej Mould blow unit with pressure relief valvej Sorter unit (SELECTRON)j Mechanical mould closing protectionInjection unit Central injection unit, can be re-positioned and swivelled as a complete assemblyj Horizontally displaceable injec-tion unit (VARIO principle)j Adapter for parting line injection Plasticising module with univer-sal screw, central coupling and adaptive temperature regulation, available in different diameters Thermoplastic cylinder with universal screw in wear resistant executionj Thermoplastic cylinder complete with very high wear resistant equipment j Plasticising module for processing thermoset, elastomer and silicone materialsj Thermoplast screws for special applications, self-dyeing (mixing section), PVC (shear-sen-sitive), POM, PA (semi-crystalline) Programmable nozzle speeds (advance 2, retract 1 stage)