Example: air traffic controller

Aluminum Conductor 15KV 133% MV-105 EPR/PVC Copper …

1-800-945-5542 Priority Wire & Cable, Little Rock, AR PWC-2017 Aluminum Conductor 15kv 133% MV-105 EPR/PVC Copper Tape Shield Part Number Size AWG Insulation Thickness Insulation Diameter Insulation Shield Diameter Overall Diameter Approximate Weight ft. Ampacity (Amps) Conductor Diameter 105 C In Duct 105 C In Air 2-0115 KVALEPMV105 2 .220" .266 " " " 484 130 170 1/0-0115 KVALEPMV105 1/0 .220" .336 " " " 566 165 225 2/0-0115 KVAPEPMV105 2/0 .220" .379 " " 620 190 260 4/0-0115 KVALEPMV105 4/0 .220" .479 " " " 761 245 350 250-0115 KVALEPMV105 250.

1-800-945-5542 Priority Wire & Cable, Little Rock, AR PWC-2017 Aluminum Conductor 15KV 133% MV-105 EPR/PVC Copper Tape Shield Part Number Size

Tags:

  Copper, Aluminum, Conductor, 15kv, Aluminum conductor 15kv 133 mv

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Aluminum Conductor 15KV 133% MV-105 EPR/PVC Copper …

1 1-800-945-5542 Priority Wire & Cable, Little Rock, AR PWC-2017 Aluminum Conductor 15kv 133% MV-105 EPR/PVC Copper Tape Shield Part Number Size AWG Insulation Thickness Insulation Diameter Insulation Shield Diameter Overall Diameter Approximate Weight ft. Ampacity (Amps) Conductor Diameter 105 C In Duct 105 C In Air 2-0115 KVALEPMV105 2 .220" .266 " " " 484 130 170 1/0-0115 KVALEPMV105 1/0 .220" .336 " " " 566 165 225 2/0-0115 KVAPEPMV105 2/0 .220" .379 " " 620 190 260 4/0-0115 KVALEPMV105 4/0 .220" .479 " " " 761 245 350 250-0115 KVALEPMV105 250.

2 220" .522 " " " 834 270 385 350-0115 KVALEPMV105 350 .220" .622 " " " 992 330 480 500-0115 KVALEPMV105 500 .220" .742 " " " 1216 400 600 750-0115 KVALEPMV105 750 .220" .917 " " " 1574 490 780 1000-0115 KVALEPMV105 1000 .220" " " " 2028 565 940 All values are nominal and subject to correction Application: To be used in power circuits rated up to 15,000 volts. For installation in open air, duct, conduit, cable tray (1/0 and larger) or direct buried and for use in wet or dry locations. UL approved at 105 C for continuous operation, 140 C for emergency overload and 250 C during short circuit conditions.

3 Conductors: Soft bare 1350 series Aluminum , Class B stranding per ASTM Insulation: Heat and moisture resistant natural high dielectric strength EPR-based insulation per ICEA S-97-682 with a semi-conducting thermosetting insulation shield Metal Shield: Helically applied non-magnetic 5mil Copper tape with a minimum of 25% overlap Jacket: Sunlight resistant black PVC rated 90 C per UL 1277. Standards: IEEE 383 flame test (1/0 and larger) IEEE 1202 flame test (250 MCM and larger) UL 1072 type MV-105 , sunlight resistance CT use (1/0 and larger) AEIC CS8