Example: air traffic controller

Ambient Air Vaporizers

Ambient Air VaporizersTMThermafin SupergapTMAmbient VaporizersSupergapTMPerformance Thermax SupergapTMAmbient Cryogenic Vaporizershave becomethe industry standard design. SupergapTMModules use a big 5 gapbetween finned elements to resist frost clog longer, extendingeconomic use to the two-week continuous range as stand-alonemodules. When the duty cycle extends beyond the two-week range,switching systems and Hybrid Arrays are employed. Modules areavailable to over 150,000 SCFH in all-aluminum, stainless-steel lined(high pressure) and electropolished stainless steel designs. In additionto the 5 fin gap, Thermax SupergapTMModules are fully engineeredand tested to withstand the demanding thermal cycling and ice loadsgenerated on Ambient Vaporizers in long-term SupergapTMModules meet the most demanding set ofspecifications established by the Cryogenic Industrial Gas Industry: Severe thermal cycling per ANSI -- This type of service iscommon at most bulk-use customer stations where gas flows varywidely.

Ambient Air Vaporizers TM Thermafin SupergapTM Ambient Vaporizers SupergapTM Performance Thermax SupergapTM Ambient Cryogenic Vaporizershave become the industry standard design

Tags:

  Ambient, Ambient air vaporizers, Vaporizers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Ambient Air Vaporizers

1 Ambient Air VaporizersTMThermafin SupergapTMAmbient VaporizersSupergapTMPerformance Thermax SupergapTMAmbient Cryogenic Vaporizershave becomethe industry standard design. SupergapTMModules use a big 5 gapbetween finned elements to resist frost clog longer, extendingeconomic use to the two-week continuous range as stand-alonemodules. When the duty cycle extends beyond the two-week range,switching systems and Hybrid Arrays are employed. Modules areavailable to over 150,000 SCFH in all-aluminum, stainless-steel lined(high pressure) and electropolished stainless steel designs. In additionto the 5 fin gap, Thermax SupergapTMModules are fully engineeredand tested to withstand the demanding thermal cycling and ice loadsgenerated on Ambient Vaporizers in long-term SupergapTMModules meet the most demanding set ofspecifications established by the Cryogenic Industrial Gas Industry: Severe thermal cycling per ANSI -- This type of service iscommon at most bulk-use customer stations where gas flows varywidely.

2 Wind load design to 100 MPH per 1997 UBC -- High wind loadsare very common in all USA locations and must be incorporatedinto the modules design. Seismic/earthquake design per 1997 UBC -- This requirement isnow mandatory in some states and an integral part of mostspecifications. Ice load allowance based on Thermax s own 22,000 STD including eccentric force loadings due to uneven frost buildup. Crateless design standard on larger modules -- Not only does thisdesign reduce setup time at the site, but assures the customer ofreduced shipping damage and simpler relocation at lower cost. Stress-free base designs featuring Thermax Thermafin Cores onlarger modules assures you that standard weld surface cracks dueto thermal expansion/ contraction are eliminated in normal use. Thermax high-flow, high-thermal flux internal fin design withmore internal fin surface area and generous cross section allowscloser approach temperatures in the super-heat zone at very lowpressure drops.

3 Full penetration weld design in critical pressure joints, for longservice at zero leakageTF1210 HF-SG SupergapTMDAYS CONTINUOUS OPERATIONO2/N2 FLOW (SCFH) (SUMMER)(WINTER)COLD/DRY5,00010,00070,00 030,000571235710 SUPERGAP (S-G)STANDARD60% GAIN1 DAY=100%3 DAYS=75%5-7 DAYS=64%10 DAYS=50%14 DAYS=42%21 DAYS=26%USEFUL RANGE DAYSBEFORE EXCESSIVE ICE CLOGTF3612HF Comparative PerformanceTMChart Nitrogen Systems, Applied Technologies Division, Chart Industries, County Road 42 West, Burnsville, MN 55306-3803 Phone: 952-882-5000 . 888-877-3093 Local Fax: 952-882-5188 . : Air VaporizersThermafin SupergapTMThermafin Ambient Modules are available in all-aluminum,stainless steel or non-ferrous lines units to 15,000 psig (1,024 Bar).HF Series:Standard 450 psig (31 Bar) MAWP/500 psig (34 Bar) TestCustom HF:To 600 psig (41 Bar) MAWP/750 psig (52 Bar) TestSS Lined Series:300 Series SS Lined .. to 15,000 psig (1,024 Bar)SS-LP .. Bulk Service SS to 700 psig (48 Bar)SS.

4 3500 psig (241 Bar)SS .. 4500 psig (310 Bar)SS .. 6000 psig (414 Bar)SS-EP .. Electropolished -- Any pressureMonel Lined Series:M30 .. 3000 psig (207 Bar)ThermafinSupergapTM11544791TF0410HF- SG21506116004513503811003190025675192006 12521 533 21 533 134 3404 250 113 450 3111544804TF0610HF-SG3185902400682000571 60045135038100028288812521 533 33 838 147 3734 250 113 450 3111544812TF0810HF-SG4250120320091267076 2140611765501350383841112521 533 46 1143 147 3734 300 136 450 3111544821TF1210HF-SG6500184490013940001 133200912650752000575751612534 864 45 1143 147 3734 400 181 450 3111544839TF1610HF-SG8500241640018155001 56440012536501032800797902212546 1168 46 1168 147 3734 475 215 450 3111544847TF1615HF-SG1275036195502708250 23466001875440154418011811503312546 1168 46 1168 205 5207 700 318 450 3111544855TF3010HF-SG1550043911600328100 002838000227669018950001421450411 1/23859 1499 71 1803 153 3886

5 900 408 450 3111544863TF3612HF-SG2300065117250488145 0041111600328957027172502052000571 1/23871 1803 71 1803 188 4775 1600 726 450 3111544871TF3618HF-SG3350094925100711215 006091720048714200402108003063100881 1/23872 1829 72 1829 262 6655 2100 953 450 3111544880TF6420HF-SG65600185849200 1393428001212342209692822079921400606612 017325197 2464 97 2464 283 7188 3500 1588 450 3111544759TF014 AHF-SG 250719051605130410038022313/4198 203 12 305 62 1,575 19 9 600 4111544767TF024 AHF-SG500143801132092607200616054613/419 8 203 21 533 62 1,575 37 17 600 4111544775TF028 AHF-SG850247602264018520154001132099233/ 4198 203 21 533 110 2,794 58 26 600 4111544783TF048 AHF-SG 170048152043128036104029800236401818453/ 41923 584 23 584 110 2,794 125 57 600 4111551756TF0410HF-SG2150611600451350381 10031900256751920063/41921 533 21 533 134 3,404 250 113 600 4111551764TF1210HF-SG6500184490013940001 13320091265075200057575163/41934 864 45 1,143 147 3,734 400 181 600 41600 psig (41 Bar) DesignRating 02/ N2/ Ar Total DrawShipping (3)DesignPart NumberSCFH / Nm3h(Thousands)MPTinches / mmWeightPressureChartThermax8-24 hrs (2)3 days5-7 days10 days2 weeks18-21 days MSCF Nm3inches mmLengthWidthHeightlbskgpsig Bar450 psig (31 Bar) DesignRating 02/ N2/ Ar Total DrawShipping (3)DesignPart NumberSCFH / Nm3h(Thousands)inches / mmWeightPressureChartThermax8-24 hrs (2)

6 3 days5-7 days10 days2 weeks18-21 daysMSCFNm3inchesmmLengthWidthHeightlbsk gpsig BarStandard SupergapTMModules / Rating Table and DimensionsStandard ConnectionMueller Flange& Mates (1)Standard Connection(1)1" Mueller Flange = 1 1/8" ; 11/2" Mueller Flange = 1 5/8" ;2" Mueller Flange = 2 1/8" (2)8-24 hour rating is based on the Industrial Gas Industry Standard Rating ofapproximately 11 SCFH / ft2( Nm3h/m2)of external finned surface and a 10o/ 20oF(-12o / -7oC) approach temperature of 70oF (21oC)/ 70% RH in HF series AluminumModules.(3)Shipping weight & dimensions are tables shown are intended as guides reflecting our experience on these models. Actual performance may product and/or data was designed and/or developed by Thermax Inc. and shall not be used in any way injuriousto the interests of Thermax Inc. Thermafin SupergapTM is a Thermax Inc. Inc. 2001 all rights reserved, Revision 10/01. THERMAX Dartmouth St., Dartmouth, MA 02748 Vaporizers , HEAT EXCHANGERS,THERMAL SYSTEMS, CRYOGENIC EQUIPMENT