Example: dental hygienist

AMERICAN CRAFTSMAN WINDOWS

GLAZING DETAIL 1 EXTERIORINTERIORMIN. GLASS BITE 7/16"1/8" OR 3/32"SETTING BLOCK43/64" LAMINATED GLASSCONSISTING OF:1/8" ANNEALED GLASS7/32" STEEL SPACER3/32" ANNEALED " SAFLEX PVB INTERLAYER BY EASTMAN CHEMICAL COMPANY3/32" ANNEALED GLASSSTEEL SPACERDOW 995 SEALANTTREMCO S700 SEALANTNOTE:ALL GLAZING CONFIGURATIONS SHALL COMPLY WITHSAFETY GLAZING REQUIREMENTS OUTLINED INCURRENT FBC AND ASTM E 1300 GLASS CRAFTSMAN WINDOWSSILVER LINE WINDOWS AND DOORS70 SERIES / V1 SERIES / (2127)SINGLE- HUNG WINDOWS (HVHZ)(IMPACT)GENERAL NOTES:1.

channel screw in the interior channel anchor schedule method substrate anchor schedule min embedment min. edge distance nailing fin wood: min. sg = 0.55 #8 wood screw pan head 1.5" 0.75" metal: 18 gauge steel, min. fy = 33ksi #8 tek screw 3 threads min penetration beyond metal 0.50" through frame wood: min. sg = 0.55 #10 pan head in exterior ...

Tags:

  Metal, Channel

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of AMERICAN CRAFTSMAN WINDOWS

1 GLAZING DETAIL 1 EXTERIORINTERIORMIN. GLASS BITE 7/16"1/8" OR 3/32"SETTING BLOCK43/64" LAMINATED GLASSCONSISTING OF:1/8" ANNEALED GLASS7/32" STEEL SPACER3/32" ANNEALED " SAFLEX PVB INTERLAYER BY EASTMAN CHEMICAL COMPANY3/32" ANNEALED GLASSSTEEL SPACERDOW 995 SEALANTTREMCO S700 SEALANTNOTE:ALL GLAZING CONFIGURATIONS SHALL COMPLY WITHSAFETY GLAZING REQUIREMENTS OUTLINED INCURRENT FBC AND ASTM E 1300 GLASS CRAFTSMAN WINDOWSSILVER LINE WINDOWS AND DOORS70 SERIES / V1 SERIES / (2127)SINGLE- HUNG WINDOWS (HVHZ)(IMPACT)GENERAL NOTES:1.

2 THE PRODUCT SHOWN HEREIN IS DESIGNED ANDMANUFACTURED TO COMPLY WITH THE CURRENT EDITIONFLORIDA BUILDING CODE (FBC), INCLUDING HVHZ AND HASBEEN EVALUATED ACCORDING TO THE FOLLOWING: TAS 201-94 TAS 202-94 TAS 203-94 ASTM E330-02 ASTM E1886-12 ASTM E1996-17 AAMA/WDMA/CSA 101 ADEQUACY OF THE EXISTING STRUCTURALCONCRETE/MASONRY, 2X FRAMING, AND metal FRAMINGAS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OFWITHSTANDING AND TRANSFERRING APPLIED PRODUCTLOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THEENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED ANDANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE.

3 BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF THE INSTALLATION DETAILS DESCRIBED HEREIN AREGENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FORA SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATIONTO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN,A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITESPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT INNON-HVHZ AREAS. IN HVHZ AREAS, ONE TIME PRODUCTAPPROVAL TO BE OBTAINED FROM MIAMI-DADE RER APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIREDON THIS PRODUCT IN AREAS REQUIRING WINDOW FRAME MATERIAL: PVC7.

4 IN ACCORDANCE WITH THE CURRENT EDITION FBC, WOODCOMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATEDOR SHALL BE OF A DURABLE SPECIES AS DEFINED INCHAPTER GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 GLASS CHARTS. SEE SHEET 1 FOR GLAZING & GENERAL NOTESTABLE OF CONTENTSSHEET REVISIONSHEET DESCRIPTION1-GENERAL NOTES & GLAZING DETAIL2 ELEVATION & ANCHOR LAYOUTS345----SHEET:DWG. #:1 SWD050 BUILDING DROPS, E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004PH: (954)399-8478 FAX: (954) : :NTSHRDWG. BY: BY:HFNREMARKSTITLE:BY DATE\\bdllc-srv\Common\Projects\Library\ Logos\ 3:32 PMs:\projects\silver line WINDOWS and doors\cc-20-0920-fbc code change (ver.)

5 7)\dwgs\fl14911\ #:PREPARED BY:HERMES F. NORERO, No 73778 BUILDING DROPS, INC398 E. DANIA BEACH BLVD. # 338 DANIA BEACH, FL 33004 FBPE CERT. OF AUTHORIZATION No. 2957870 SERIES/ V1 SERIES/ (2127)SINGLE- HUNG WINDOWS (HVHZ)(IMPACT)THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERICAND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFICSITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFICDOCUMENTS FOR USE WITH THIS CRAFTSMAN WINDOWSSILVER LINE WINDOWS AND DOORSONE SILVER LINE DRIVENORTH BRUNSWICK, NJ 08902PH.

6 (888) 741-03547TH FBC EDITION NUS10/14/20 HORIZONTAL SECTIONSWIDTHHEIGHTMAX OVERALL SIZEDESIGNPRESSUREMISSILEIMPACT & VERTICAL SECTIONS, INSTALLATION NOTES &REINFORCEMENT DETAILSVERTICAL SECTIONS52"+55 / -60 PSF73"O/XLMI/SMIELEVATIONSINGLE HUNG WINDOWANCHOR LAYOUTNAIL FIN - SINGLE HUNG WINDOWMAX. FRAMEHEIGHT 73"MAX. FRAMEWIDTH 52"4CA3"X""O"3" " " " LAYOUTTHROUGH FRAME - SINGLE HUNG " " " "MAX. "MAX. "B3 NOTE:ALL FASTENERS ABOVETHE MEETING RAIL INTHE INTERIOR JAMBTRACK MUST BE FLAT HEAD"X""O""X""O"4 DELEVATIONS & ANCHOR LAYOUTSSHEET:DWG.

7 #:2 SWD050 BUILDING DROPS, E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004PH: (954)399-8478 FAX: (954) : :NTSHRDWG. BY: BY:HFNREMARKSTITLE:BY DATE\\bdllc-srv\Common\Projects\Library\ Logos\ 3:32 PMs:\projects\silver line WINDOWS and doors\cc-20-0920-fbc code change (ver. 7)\dwgs\fl14911\ #:PREPARED BY:HERMES F. NORERO, No 73778 BUILDING DROPS, INC398 E. DANIA BEACH BLVD. # 338 DANIA BEACH, FL 33004 FBPE CERT. OF AUTHORIZATION No. 2957870 SERIES/ V1 SERIES/ (2127)SINGLE- HUNG WINDOWS (HVHZ)(IMPACT)THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERICAND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFICSITE.

8 IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFICDOCUMENTS FOR USE WITH THIS CRAFTSMAN WINDOWSSILVER LINE WINDOWS AND DOORSONE SILVER LINE DRIVENORTH BRUNSWICK, NJ 08902PH: (888) 741-03547TH FBC EDITION NUS10/14/20 MAX. FRAME HEIGHTINTERIOREXTERIORSEE GLAZINGDETAIL, SHEET 1 SEE GLAZINGDETAIL, SHEET FRAME HEIGHTINTERIOREXTERIORSEE GLAZINGDETAIL, SHEET 1 SEE GLAZINGDETAIL, SHEET SECTIONNAIL FINA3 VERTICAL SECTIONTHRU FRAMEBVERTICAL SECTIONSSHEET:DWG.

9 #:3 SWD050 BUILDING DROPS, E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004PH: (954)399-8478 FAX: (954) : :NTSHRDWG. BY: BY:HFNREMARKSTITLE:BY DATE\\bdllc-srv\Common\Projects\Library\ Logos\ 3:32 PMs:\projects\silver line WINDOWS and doors\cc-20-0920-fbc code change (ver. 7)\dwgs\fl14911\ #:PREPARED BY:HERMES F. NORERO, No 73778 BUILDING DROPS, INC398 E. DANIA BEACH BLVD. # 338 DANIA BEACH, FL 33004 FBPE CERT. OF AUTHORIZATION No. 2957870 SERIES/ V1 SERIES/ (2127)SINGLE- HUNG WINDOWS (HVHZ)(IMPACT)THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERICAND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFICSITE.

10 IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFICDOCUMENTS FOR USE WITH THIS CRAFTSMAN WINDOWSSILVER LINE WINDOWS AND DOORSONE SILVER LINE DRIVENORTH BRUNSWICK, NJ 08902PH: (888) 741-03547TH FBC EDITION NUS10/14/204 HORIZONTAL SECTIONLOWER SASHDSEE GLAZINGDETAIL SHEET 1 EXTERIORINTERIORSEE GLAZINGDETAIL SHEET 14 HORIZONTAL SECTIONUPPER SASHCSEE GLAZINGDETAIL SHEET 1 MAX. FRAME GLAZINGDETAIL SHEET 1 EXTERIORINTERIORMAX.