ETHERSEAL CONNECTIVITY SYSTEMB ringing Ethernet and Structured Cabling to Non-Office Environments From the factory floor to the hospital room, Ethernet is the network type of choice. More and moreTCP/IP applications running across Ethernet networks find their way into non-office and harshenvironments. The AMP NETCONNECT EtherSeal Connectivity System will help protect critical datacommunication against temperature and moisture extremes, dust, vibration, EMI noise and chemicalexposure while providing protection against accidental disconnects.

D B Product Facts:: Meet or exceed TIA and ISO component performance requirements:: IP67 compliant:: Available for Shielded and Unshielded Systems

Tags:

  Shielded

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of AMP NETCONNECT - YE International

1 ETHERSEAL CONNECTIVITY SYSTEMB ringing Ethernet and Structured Cabling to Non-Office Environments From the factory floor to the hospital room, Ethernet is the network type of choice. More and moreTCP/IP applications running across Ethernet networks find their way into non-office and harshenvironments. The AMP NETCONNECT EtherSeal Connectivity System will help protect critical datacommunication against temperature and moisture extremes, dust, vibration, EMI noise and chemicalexposure while providing protection against accidental disconnects.

2 Traditional Ethernet connectors and cables are being designed into environments that far surpass theenvironmental specification of the standard connectors found in offices. In some instances thesetraditional components require positive, secure locking of the connection beyond their physical is the de facto standard for any application that requires data transmission or acquisition. It iscost-effective and offers the speed, reliability and wide-spread acceptance needed for today's networkapplications. The EtherSeal Connectivity System uses components compliant with existing cablingstandards and adds additional benefits of mechanical performance, construction and secure mating.

3 Conventional commercial connectivity systems are not an option in harsh environment , the non-commercial office, IP67 customerrequires the same flexibility, cost base and availabilityof components. Other connector latching mechanismsused extensively in these environments are or bayonet type couplers do not providevisual and audible confirmation for positive mating. TheAMP NETCONNECT EtherSeal Connectivity System notonly offers compliance with existing standards andusability in harsh environments, but also theperformance and reliability needed to secure networksfor proposed and future NETCONNECT SYSTEM FEATURES & BENEFITS::TIA and ISO Category 5e and IEC60529 IP67 compliant::Uses industrial grade materials::Uses the same high-performanceAMP NETCONNECT Category 5ecomponents as standard product lines::Complete Cat 5e cabling solution forboth harsh and office environments.

4 Equipment interface receptaclesavailable through Tyco Electronics::Positive latching mechanism ::Push-On and Twist Off Mating Action::Blind mating with Polarized Keying ::Tactile feedback that confirms fullmating::Eliminates accidental disconnectswhen properly connectedDBProduct Facts::Meet or exceed TIA and ISO componentperformance requirements::IP67 compliant::Available for shielded and Unshielded Systems::Traditional 110 tool and toolless versions::Front-loading into enclosures and outlets::Push-On and Twist Off Mating Action::Blind mate with Polarized Keying ::Tactile feedback confirms fully mated::Optional Outlet Cap with tether availableADCD escriptionFig.

5 Part NumberCategory 6 UnshieldedA1479565-2SL Series 110 Connect Modular Jack KitShieldedB1479566-2 Category 5eUnshieldedA1479563-2 ShieldedB1479564-2SL Series Toolless Modular Jack KitCategory 5eUnshieldedC1479561-2 shielded D1479562-2SL Series Modular Coupler KitCategory 5eUnshieldedE1479599-2 shielded -1479600-2 Modular Jack CapF1479591-2 AFDescriptionFigurePart NumberCategory 6 UnshieldedASolid 1479682-2 Stranded1479683-2 UnshieldedBSolid1479583-2 Modular Plug KitStranded1479584-2 Category 5eShieldedCSolid1479585-2 Stranded1479586-2 Modular Plug CapD1479592-2 CBEP roduct Facts::Meet or exceed TIA and ISO component performance requirements::IP67 compliant::Available for shielded and Unshielded Systems::Available for solid and stranded cable::Push-0n and twist off mating action::Blind mate with Polarized Keying ::Tactile feedback confirms fully mated::Optional plug cap with available tether.

6 Category 6 Modular Plug Kit can be used for either shielded or unsheilded Modular Jack and Coupler Outlet KitsEtherSeal Modular Plug KitsCBProduct Facts::Available in single and double gang::Accepts EtherSeal Jack or Coupler Kits(purchased separately)::Available with and without gaskets::Part Number 1479596 accepts two portsof EtherSeal Outlet Kits and two portsstandard SL Series or 110 Connect modular Jacks, SL Series Multimedia Jacksor SL Series or 110 Connect InsertsDescriptionFigurePart NumberWith GasketWithout GasketSingle Gang1-PortA1479593-21479593-12-PortB1479 594-21479594-1 Double Gang4-PortC1479595-21479595-12-Ports/2-P ortsD1479596-21479596-1 ADEtherSeal Stainless Steel 2A 1479654-1 Enclosure.

7 44- 1B 1479655-1 Indoor/Outdoor221-C 1479656-1 BACBCP roduct Facts::Cable and conduit glands provide a wayto seal cable or conduit entries into EtherSeal Connector EnclosuresDescriptionFor use withFigurePart NumberM16 CableA1479657-1 Gland KitsM323/4" ConduitB1479658-1M401" ConduitC1479659-1 ATRIMP roduct Facts::NEMA 4 and 4X rated::IP67 compliant when installed perinstruction sheets::Can be used in either indoor or outdoorenvironments::Provides fully sealed remote access todata and telephone services::Knockouts provide easy configuration forcustomer requirements::Knockouts per enclosure as listed ::Cable and conduit glands provide a wayto seal cable and or conduit entriesEtherSeal EnclosuresEtherSeal Cable & Conduit GlandsDescriptionPart NumberEtherSeal to EtherSealUnshielded1479601-XShielded1479 603-XEtherSeal to Standard Unshielded1479602-XRJ-45 Modular PlugShielded1479604-XModular Plug Cap1479592-2X= Denotes length in feet.

8 -3= 3, -5= 5, -7= 7, 1- -0= 10, 1- -5 = 15 Product Facts::Meets or exceeds TIA and ISO Category5e/Class D specifications::IP67 compliant:: shielded and unshielded cable assemblies available::Utilizes EtherSeal industrial grade Cat 5ecable::Factory-terminated and tested for quality ::Both EtherSeal to EtherSeal and EtherSealto standard modular plug versions available::Push-on and twist off mating actionProduct Facts::Meets or exceeds TIA and ISO Category5e/Class D specifications::Exceeds all requirements for GigabitEthernet::Sunlight (UV) resistant for harshenvironments::Oil resistant, Level II::Double jacketed - PVC ::CMR (Riser) rated.

9 Available in shielded and unshielded, solidand stranded constructionsUL/NECPairJacketPackagingCo nductorPart RatingsCountColorNumberSolidUTP1499447-3 FTP1499449-3 CMR4-PairGrey1000ft, UTP1499448-3 Wooden ReelsStrandedScTP 1499450-3 TRIME therSeal Category 5e Cable AssembliesEtherSeal Category 5e CableIn the Mexico525-729-0400 South and Central Americas54-11-4733-2200 : Copyright 2004 Tyco Electronics Corporation. All rights reserved. Printed in USAAMP, AMP NETCONNECT , EtherSeal, NETCONNECT and Tyco are trademarks.

10 Other products, logos, and Companynames mentioned herein may be trademarks of their respective Electronics reserves the right to change part numbers and discontinue parts without From Vertical60 From VerticalXIEC 60529:2001-02 - Degrees of protection provided by enclosures (IP Code)IP Code = IPXYP rotection from foriegn objectsUnprotectedProtected frompenetration of solidobjects > mm frompenetration of solidobjects > mm frompenetration of solidobjects > mm frompenetration of solidobjects > mm protectedfrom dust.