Example: biology

aNd oWer ords - Qualtek USA

CoNduCtor PoWer Cords220002-01221001-01221001-03221001-0 8221002-01223020-01 223021-01 223082-01 223083-01 AAAAABBBB9 0 6 0 6 0 6 0 9 0 6 0 8 0 6 0 8 0 18181818181818181810101010107777 SPT-1 SPT-1 SPT-1 SPT-1 SPT-1 SPT-2 SPT-2 SPT-2 SPT-21-15P1-15P *1-15P *1-15P *1-15P *1-15P 1-15P1-15P *1-15P *Split Split Split SplitSplit C7C7C7 *C7 *3 CoNduCtor PoWer Cord With North AmeriCaN CoLor Code211011-01211011-06211012-06211017-06 211018-06212004-01212013-01212099-012250 03-01226003-01 227003-01 228003-01 CCCCCCCCDEFG6 0 6 0 8 0 6 0 8 0 7 6 7 6 6 0 8 2 8 2 8 2 8 2 1818181818181618141412121010101010101310 15152020 SVTSVTSVTSJTSJTSVTSJTSVTSJTSJTSJTSJT5-15 P5-15P5-15P5-15P5-15P5-15P5-15P5-15P5-15 P6-15P5-20P6-20 PROJROJROJROJROJC13C13C13C19C19C19C193 CoNduCtor PoWer Cord With CEE CoLor Code311007-01311010-01311013-01311016-01 311019-01311022-01311024-01311027-013110 30-01 311275-01311276-01312003-01312003-063120 07-01312008-01312010-01 CCCCCCCCCCCCCCCC6 7 9 10 6 7 9 10 6 7 9 10 6 7 9 10 6 7 12 0 15 0 7 6 7 6 6 7 7 6 9 10 :All North American cords are 125 VAC / 60 C unless marked otherwise (adjacent to the part number)Cords marked ROJ: outer jacket is removed 2 and stripped 5/8 Cords marked Split: outer jacket is split 1 1/2 and stripped 5/8 North American Color Code: Black, White, GreenCEE Color C

hospitaL grade poWer Cords www.Qualtekusa.com Nema straight bLade aNd LoCKiNg deViCes a b C d e Notes: All Cords are 125VAC / 60°C unless marked North American Color Code: Black, White, Green

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of aNd oWer ords - Qualtek USA

1 CoNduCtor PoWer Cords220002-01221001-01221001-03221001-0 8221002-01223020-01 223021-01 223082-01 223083-01 AAAAABBBB9 0 6 0 6 0 6 0 9 0 6 0 8 0 6 0 8 0 18181818181818181810101010107777 SPT-1 SPT-1 SPT-1 SPT-1 SPT-1 SPT-2 SPT-2 SPT-2 SPT-21-15P1-15P *1-15P *1-15P *1-15P *1-15P 1-15P1-15P *1-15P *Split Split Split SplitSplit C7C7C7 *C7 *3 CoNduCtor PoWer Cord With North AmeriCaN CoLor Code211011-01211011-06211012-06211017-06 211018-06212004-01212013-01212099-012250 03-01226003-01 227003-01 228003-01 CCCCCCCCDEFG6 0 6 0 8 0 6 0 8 0 7 6 7 6 6 0 8 2 8 2 8 2 8 2 1818181818181618141412121010101010101310 15152020 SVTSVTSVTSJTSJTSVTSJTSVTSJTSJTSJTSJT5-15 P5-15P5-15P5-15P5-15P5-15P5-15P5-15P5-15 P6-15P5-20P6-20 PROJROJROJROJROJC13C13C13C19C19C19C193 CoNduCtor PoWer Cord With CEE CoLor Code311007-01311010-01311013-01311016-01 311019-01311022-01311024-01311027-013110 30-01 311275-01311276-01312003-01312003-063120 07-01312008-01312010-01 CCCCCCCCCCCCCCCC6 7 9 10 6 7 9 10 6 7 9 10 6 7 9 10 6 7 12 0 15 0 7 6 7 6 6 7 7 6 9 10 :All North American cords are 125 VAC / 60 C unless marked otherwise (adjacent to the part number)Cords marked ROJ: outer jacket is removed 2 and stripped 5/8 Cords marked Split: outer jacket is split 1 1/2 and stripped 5/8 North American Color Code: Black, White, GreenCEE Color Code: Brown, Blue, Green/Yellow stripeCustom Designs AvailableKey.

2 - Voltage Rating 250 VAC - Temperature Rating 105 C* - Polarized+ - RA = Right Angle - Split 2 and stripped 5/8 Color designated by suffix (-xx)-01 Black-03 Brown-06 Gray-08 White-12 IvoryOther colors CoNduCtor PoWer Cord With CEE CoLor Code312011-01312014-01312016-01312019-01 312021-01 312126-01312127-01312128-01 313001-01313003-01313006-01313009-013130 10-01313011-01313014-01315005-01315008-0 1315086-01 316005-01 316009-01 317003-01 317005-01 318002-01 318004-01 318005-01 318007-01 331010-01 338010-01350049-LD01350050-LD01 CCCCCCCCCCCCCCCHHHHHHHHHHHIJKK6 7 9 10 6 7 9 10 7 6 12 0 15 0 6 0 7 6 6 7 6 7 9 10 6 7 7 6 9 10 6 7 9 10 9 10 6 7 6 7 4 11 3 3 3 3 1 8 3 3 3 3 9 10 7 6 6 0 10 0 1616141418181818181818181616161818181816 1818181818161416181813131515101010101010 1010131313101010101310101010101315131010 SJTSJTSJTSJTSVTSJTSJTSVTSVTSVTSJTSJTSJTS JTSJTSJTSJTSJTSJTSJTSVTSJTSVTSJTSJTSJTSJ TSJTSVTSVT5-15P5-15P5-15P5-15P5-15P5-15P 5-15P5-15P5-15P5-15P5-15P5-15P5-15P5-15P 5-15

3 PROJROJROJROJROJC14C14C14C14C14C14C205-1 5P5-15P5-15PC13C13C13C13C13C13C13C13C13 RA +C13 RA +C13 RA +C13 RA +C13 RA +C13 RA +C13 RA +C13C13C13C13 RA +C13 RA +ROJROJC13C13C13C13C19C15C5C52 aNd 3 CoNduCtor North ameriCaN poWer CordsaCdeFghiJKbiNterNatioNaL poWer :All International cords are 250 VAC / 70 C, with CEE color code, (except Japan) unless marked otherwise (adjacent to the part number)Japan cords are North American Color Code, 125 VAC / 60 CCords marked ROJ: outer jacket is removed 50mm and stripped 5mmNorth American Color Code: Black, White, GreenCEE Color Code: Brown, Blue, Green/Yellow stripeCustom Designs AvailableKey: - Voltage Rating 125 VAC - Temperature Rating 105 C* - Polarized+ - RA = Right AngleColor designated by suffix (-xx)-01 Black-03 Brown-06 Gray-08 White-12 IvoryOther colors ampCordagepLugtypeCoNNtypeUNiVersaL Jumper Cords (WorLdWide ApproVaLs)

4 319002-T01 H3 3 AWG H8 2 BS 1363 AUK BS 1363 AUK BS 1363 AUK BS 1363 AROJROJROJC13 CoNtiNeNtaL 7/16 CEE 7/16 CEE 7/16 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 RA +CEE 7/7 RA + CEE 7/7 RA +CEE 7/7 RA +C7C7 ROJROJROJROJC13C13 RA + 3112AS 3112AS 3112AS 2073 IRAM 2073 IRAM 8305 KSC 32SI 32SI 23-50 CEI 23-50 CEI 23-50 CEI 23-50 ROJROJC13C13 JapaN397002-01397003-01397004-01397005-0 1U U U U 8303 JIS 8303 JIS 8303 JIS 1011 SEV 1011 SEV 1011 SEV 1011 SEV 1011 SEV 14136 NBR 14136 NBR 14136 NBR 1002GB 1002GB 1002GB 1002 ROJROJC13C13hospitaL grade poWer straight bLade aNd LoCKiNg deViCesabCdeNotes:All Cords are 125 VAC / 60 C unless marked North American Color Code: Black, White, Green+ - RA = Right AngleCords marked ROJ: outer jacket is removed 2 and stripped 5/8 Color designated by suffix (-xx)-01 Black-03 Brown-06 Gray-08 White-12 IvoryOther colors availablePlugs and connectors available in Clear, Gray & Black colorsCustom Designs AvailableabCdeFghiJKLN otes.

5 Plugs and connectors also available in black housing with white insert, add -BW suffix to part Grade PoWer Cords With North AmeriCaN CoLor Code232003-06232010-06232011-06232015-06 233002-06233003-06233008-06233009-062330 56-06233057-01233058-01233080-06233081-0 6233082-06233084-06233085-06233086-06240 003-06240009-06243003-06 AAAABBBBBBBCDCBBBEEB10 0 8 0 10 0 12 0 8 0 10 0 8 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 8 0 10 0 12 0 10 0 10 0 10 0 1818181618181818161616121214181816181818 1010101010101010131313152015101013101010 SJTSJTSJTSJTSJTSJTSJTSJTSJTSJTSJTSJTSJTS JTSJTSJTSJTSJTSJTSJT5-15P Clear5-15P Gray5-15P Gray5-15P Gray5-15P Clear5-15P Clear5-15P Gray5-15P Gray5-15P Gray5-15P Clear5-15P Black5-15P Gray5-20P Clear5-15P Gray5-15P Clear5-15P Clear5-15P Clear5-15P Clear5-15P Gray5-15P RA Clear +ROJROJROJROJC13 GrayC13 GrayC13 GrayC13 GrayC13 GrayC13 BlackC13 BlackC19 GrayC19 GrayC19 GrayC13 ClearC13 ClearC13 GrayC13 RA Gray + C13 RA

6 Gray +C13 GraypartNumberFigratiNgdesCriptioNCoLort ypeNEMA Straight BLade DeViCes 15A & 20AQ-710Q-712Q-716Q-718Q-720Q-722Q-726Q- 728 ABCDEFGH15A / 125 VAC15A / 125 VAC20A / 125 VAC20A / 125 VAC15A / 250 VAC15A / 250 VAC20A / 250 VAC20A / 250 VACNEMA 5-15P NEMA 5-15 RNEMA 5-20 PNEMA 5-20 RNEMA 6-15 PNEMA 6-15 RNEMA 6-20 PNEMA 6-20 RBlackBlackBlackBlackBlackBlackBlackBlac kPlugConnectorPlugConnectorPlugConnector PlugConnectorpartNumberFigratiNgdesCript ioNCoLortypeNEMA LoCKiNg DeViCes 15AQ-810Q-822Q-610Q-622 IJKL15A / 125 VAC15A / 250 VAC15A / 125 VAC15A / 250 VACNEMA L5-15 PNEMA L6-15 PNEMA L5-15 RNEMA L6-15 RBlackBlackBlackBlackPlugPlugReceptacleR eceptacleFLeXibLe Cord aNd CabLe desigNatioNsE = Thermoplastic ElastomerH = Heater CordS = Service (600V)J = Junior (300V)V = Vacuum Cleaner CordP = Parallel CordO = Oil Resitant* T = Tinsel Cord (If First Letter)T = Thermoplastic (After First Letter)W = Weather Resistant* Single O means jacket is oil resistant.

7 Double O means jacket and conductor insulation are oil StandardVOLTAGE RATING300/300V300/500V450/750 VCONDUCTOR INSULATIONPVCR ubber (Natural or Synthetic)Polychloropene RubberSilicone RubberGlass Fiber ConstructionCABLE JACKETPVCR ubber (Natural or Synthetic)Polychloropene RubberGlass Fiber ConstructionSPECIAL COMPONENTR arely UsedCONSTRUCTION DETAILFlat, Separate CableFlat, Non-Separate CableCONDUCTOR CONSTRUCTIONS olidStrandedFine Wire-Stationary InstallFine Wire-Flexible CableExtra Fine Wire-Flex CordageTinsel CordNUMBER OF CONDUCTORSQ uantityWith Ground ConductorsWithout Ground ConductorsCROSS SECTIONAL SIZE OFCONDUCTORS IN MMF3G100HA030507 VRNSJVRNTD3HH2 URKFHYGX harmoNized Wire CodiNg system & CLassiFiCatioNExample: Harmonized code for cordage H05 VVF 3G ratiNgSPT-1 SPT-2 SPT-3 SPE-1 SPE-2 SPE-3 SVSVOSVOOSVTSVTOSVTOOSVESVEOSVEOOSJSJOSJ OOSJOOWSJTSJTWSJTOS ervice Parallel ThermoplasticSPT-1 with Thicker InsulationSPT-2 with Thicker InsulationService Parallel ElastomerSPE-1 with Thicker InsulationSPE-2 with Thicker InsulationService VacuumSV with Oil Resistant JacketSVO with Oil Resistant JacketService Vacuum ThermoplasticSVT with Oil Resistant JacketSVTO with Oil Resistant InsulationService Vacuum ElastomerSVE with Oil Resistant JacketSVEO with Oil Resistant InsulationService JuniorSJ with Oil Resistant JacketSJO with Oil Resistant InsulationSJOO with Weather Resistant JacketService Junior ThermoplasticSJT with Weather Resistant JacketSJTO with Oil Resistant Jacket3003003003003003003003003003003003 00300300300300300300300300300300typedesC riptioNVoLtage

8 RatiNgSJTOOSJESJEWSJEOSJEOWSJEOOSSOSOOSO OWSTSTWSTOSESEOSEOWSEOOHPNHSJHSJOHSHSOSJ TO with Oil Resistant InsulationService Junior ElastomerSJE with Weather Resistant JacketSJE with Oil Resistant JacketSJEO with Weather Resistant JacketSJEO with Oil Resistant InsulationServiceService with Oil Resistant JacketSO with Oil Resistant InsulationSOO with Weather Resistant JacketService ThermoplasticST with Weather Resistant JacketST with Oil Resistant JacketService ElastomerSE with Oil Resistant JacketSEO with Weather Resistant JacketSEO with Oil Resistant InsulationHeater Parallel NeopreneHeater Service JuniorHSJ with Oil Resistant JacketHeater ServiceHS with Oil Resistant Jacket3003003003003003006006006006006006 00600600600600600300300300300300 CabLe CLassiFiCatioNsPC-0300 Primary Power Components DivisionAC ReceptaclesA complete line of inlets, outlets, multifunction modules with major international approval marks thus assuring high safety standards and help customers comply with international regulations.

9 Modern production methods enable us to manufacture cost-effective and reliable components. A full range of products are maintained in inventory for quick on-time deliveries. Custom designs are available upon BreakersQLB and QMB series are compact and cost effective thermal circuit breakers with a wide range of amp ratings from 3A - 40A and offered in single pole and push-to-reset with safety agency certifications. We offer a large variety of bushing types, terminals, name plates, button colors and printing with custom configurations FiltersEMI/RFI power line filters are designed to meet most international safety agency requirements. These filters help customers meet FCC and VDE emission standards. Our line consists of many standard configurations such as block type, filter with power line connector, and various filters with multifunctional modules. Custom designs are available upon request.

10 Power CordsA large selection of North American and International Power Cords that have been designed to comply with North American and international safety agency regulations to insure safe and reliable products. Offered in a wide selection of plugs and connectors available in various cable insulations, voltage ratings, colors, lengths, shielding and a full range of hospital grade certified power cords. Custom configurations and strain reliefs are available upon SuppliesA full range of low cost, high reliability and energy saving switch mode AC/DC power supplies consisting of enclosed, open frame models and waterproof LED drivers; our enclosed versions are rated from 15W - 600W, open frame from 20W - 125W and LED drivers with constant current 25W - 200W and constant voltage 25W - 300W. All models have universal voltage input and a variety of output voltages ranging from - 445V and some models include power factor correction to increase efficiency and reduce power losses.