Example: quiz answers

Aqua Pump/PowerHead - riopump.net

Rio+ 2500 Rio+ 31000100/378200/757300/1136400/1514500/1 892600/2271700/2649800/3028900/3407 Rio+ 200 Rio+ 180 Rio+ 90 Rio+ 506 + 50 Rio+ 90 Rio+ 400 Rio+ 600 Rio+ 1100 Rio+ 1400 Rio+ 180 Rio+ 200 Rio+ 800 Rio+ 1000 Rio+ 1700 Rio+ 2100123 FLOW CHART GRAPHWARNING & SAFEGUARDS Read and follow the guidelines to ensure the proper use and application of this Rio Plus pump. Failure to follow these guidelines may result in damage to the aquatic environment and serious and safety Precautions The National Code requires that a GFCI (Ground Fault Circuit Interrupter) be utilized in the branch circuit supplying all water pump and aquarium electrical equipment. If you do not have a GFCI, please see your local electrical supplier for this Warning and Safeguards Do not operate pump with Rio Plus pump without being fully submersed at all times.

Rio+ 2500 Rio+ 3100 0 100/378 200/757 300/1136 400/1514 500/1892 600/2271 700/2649 800/3028 900/3407 Rio+ 50 Rio+ 90 Rio+ 180 Rio+ 200 0 ft. 1 ft. 2 ft. 3 ft. 4 ft. 6 ft.

Tags:

  Pumps, Aqua, Aqua pump powerhead, Powerhead

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Aqua Pump/PowerHead - riopump.net

1 Rio+ 2500 Rio+ 31000100/378200/757300/1136400/1514500/1 892600/2271700/2649800/3028900/3407 Rio+ 200 Rio+ 180 Rio+ 90 Rio+ 506 + 50 Rio+ 90 Rio+ 400 Rio+ 600 Rio+ 1100 Rio+ 1400 Rio+ 180 Rio+ 200 Rio+ 800 Rio+ 1000 Rio+ 1700 Rio+ 2100123 FLOW CHART GRAPHWARNING & SAFEGUARDS Read and follow the guidelines to ensure the proper use and application of this Rio Plus pump. Failure to follow these guidelines may result in damage to the aquatic environment and serious and safety Precautions The National Code requires that a GFCI (Ground Fault Circuit Interrupter) be utilized in the branch circuit supplying all water pump and aquarium electrical equipment. If you do not have a GFCI, please see your local electrical supplier for this Warning and Safeguards Do not operate pump with Rio Plus pump without being fully submersed at all times.

2 Not doing so can cause permanent damage to the pump. Never operate Rio Plus pump with an electronic wave maker or timing device. As such devices will cause permanent damage to the pump and/or demagnetize the magnetic impeller. Replace the impeller and or shaft if there is any excess signs of wear Prior to maintenance on any electrical aquarium appliance or maintenance to the aquarium, you must disconnect all electrical aquarium PART: Magnet Mount Item L x H x W (approx.) Rio PlusGlass ThicknessUPC No. x x (5 x x )10003/8in (10mm)0870 6 MM2001/2in (12mm)0846 1MM3001100-14000847 8MM3501700-25000869 x x ( x 11x )31003/4in (19mm)0848 5 Needle Wheel Impeller Create finest bubbles & Ceramic bearing. Rio Needle wheel impellers are designed to create finest bubbles creating extra surface area and contact time in the skimmer.

3 Made with the finest materials all impellers made with ceramic bearing embedded in the rotor for longevity and durability. Combine with newly designed intake venturi and you can turbo charge your skimmer. Rio Needle wheel impellers can be retrofitted to operate on Rio plus pumps models 1000-3100 No. 0006760 Rio+ needle wheel impeller 10000853 9 Rio+ needle wheel impeller 14000854 6 Rio+ needle wheel impeller 21000855 3 Rio+ needle wheel impeller 31000856 0 Needle Wheel Impeller Conversion Kit Ceramic bearing and shaft Needle wheel made of high impact plastic Large intake venturiDescriptionUPC No. 0006760 Rio Plus needle wheel impeller conversion kit 1000 1410 3 Rio Plus needle wheel impeller conversion kit 1100-1400 1407 3 Rio Plus needle wheel impeller conversion kit 1700-2500 1408 0 Rio Plus needle wheel impeller conversion kit 3100 1409 7 AVAILABLE MODELSItem No.

4 0006760 Rio Plus 5069/262 GPH/LPH Mini Pump & Powerhead1252 9 Rio Plus 50 UL 0830 0 Rio Plus 90 85/323 GPH/LPH Mini Pump & Powerhead1253 6 Rio Plus 90 UL 0831 7 Rio Plus 180 120/456 GPH/LPH Mini Pump & Powerhead1254 3 Rio Plus 180 UL 0832 4 Rio Plus 200138/524 GPH/LPH Pump & Powerhead0838 6 Rio Plus 200 UL0816 4 Rio Plus 400144/547 GPH/LPH Pump & Powerhead0839 3 Rio Plus 400 UL0817 1 Rio Plus 600200/760 GPH/LPHPump & Powerhead0840 9 Rio Plus 600 UL0818 8 Rio Plus 600 PT0842 3 Rio Plus 800211/801 GPH/LPH Pump & Powerhead0841 6 Rio Plus 800 UL0819 5 Rio Plus 800 PT0843 0 Rio Plus 1000 UL271/1030 GPH/LPH Pump & Powerhead0836 2 Rio Plus 1100 UL382/1451 GPH/LPH Pump & Powerhead0820 1 Rio Plus 1400 UL420/1596 GPH/LPH Pump & Powerhead0821 8 Rio Plus 1700 UL642/2439 GPH/LPH Pump & Powerhead0822 5 Rio Plus 2100 UL692/2630 GPH/LPH Pump & Powerhead0823 2 Rio Plus 2500 UL782/2972 GPH/LPH Pump & Powerhead0824 9 Rio Plus 3100 UL900/3420 GPH/LPH Pump & Powerhead0825 6 FLOW CHARTItem #WattsDimensions L x W x H(approx.)

5 Inches/mmGallons per hour/liters per Depth from Water Level115V/ 60Hz220V/ + 50 (UL) 37 4669/26240 -36 in(25 cm - cm)Rio+ 90 (UL) + 180 (UL) + 200 (UL) 44 60138/52485/32331 + 400 (UL) + 600 (UL/PT) + 800 (UL/PT) + 1000 99 53 65271/1030192/730126/47942 + 1100 UL2217 5 65 83382/1451352/1327295/1121236/896180 + 1400 + 1700 UL3122 70 95642/2439620/2356486/1847418/1588352/13 38180 + 2100 UL4029692/2630666/2530600/2280486/184737 5/1425200/760 Rio+ 2500 + 3100 109 80900/3420870/3306782/2972700/2660690/26 22500 inTechnological Aquatic Associated ManufacturingFax: (805) 383-3565. Aquatic Associated Manufacturing 2011 TAAM . Photos: Greg RothschildSpecifications & technical information may change without noticeWarning! Buyer/user assumes all responsibility for safety and proper use not in accordance with the directions and safety !

6 Buyer/user assumes all responsibility for safety and proper use not in accordance with the directions and safety Pump/PowerHeadAqua Pump/PowerHead Routine maintenance is required to ensure the maximum performance and the longevity of Rio Plus pump. See Maintenance Guidelines The national code requires all aquarium equipment to be plugged into a GFCI (Ground Fault circuit Interpreter) electrical outlet Do not operate if wire is damaged Do not plug into an extension cord Failure to use the main housing strainer and or filter conversion kit may allow sand and or debris into the impeller chamber thus causing permanent damage to the impeller, ceramic shaft and or the pump Do not plug into a power strip, Always plug the pump directly to a GFCI outlet using a drip loop. Rio plus pump is designed to run completely submerged in water.

7 Do not operate pump outside of water! This pump should be submerged in water before connecting to a power source. Start Pump in Water ONLY. DO NOT Run Pump in Air Rio Plus pump may be utilized in either fresh water or salt water but not in foreign fluids, flammable liquids or any chemicalWARNINGS!This product may contain chemicals known to the state of California to cause cancer and or birth defects or other reproductive harm. Wash your hand after handling this is your sole responsibilities to verify that the plug and the receptacle are clean and free of moisture and salt build up at all times. The receptacle must be free of water, salt, calcium, magnesium and dust. Failure to do so can cause fire, damage to property, permanent damage to the product and personal injury not limited to loss of life. Do not plug into extension cord/power drip loop must be used when plugging all electrical aquarium devices.

8 A drip loop is that part of the cord hanging below the national code requires that a GFCI (Ground fault circuit interrupter) be used in the branch circuit supplying all power to water pumps and electrical aquarium equipment. If you do not have a GFCI, have an electrician install one prior to operating any aquarium : It is important that the right pump and flow rate is being used for the given specific application. Use the flow chart to determine the proper size pump and tubing to be used for given application. (Section 4 continue on the other side)MAINTENANCEP reventing debris and free floating material from entering your Rio plus pump is of utmost importance to the longevity of your pump. Your pump requires regular cleaning to maintain a steady water flow. Note: Gravel, sand and calcium deposits will also diminish/damage the longevity of Rio Plus pump and IMPORTANT: You must disconnect all electrical power to the aquarium and water pump before beginning the maintenance on any electrical equipment including Rio Plus Do not use any type of soap or detergent to clean the Rio Plus pump and parts.

9 Remove main housing strainer. Clean and rinse of all dirt and debris. Carefully turn housing endcap retainer counter-clockwise to disconnect. Housing endcap, ceramic shaft and impeller may now be removed from motor housing. Rinse all dirt and grime off the impeller before reassembling. In environments that have a high amount of calcium it may be necessary to clean impeller in 1 part vinegar 3 parts water solution, this will breakdown calcium. Let soak for a minimum of 15 minutes. Clean well then verify that the impeller spins freely on the shaft. Note: Replace impeller or ceramic shaft if any signs of excess wear on impeller, ceramic shaft and/or shaft endcap. 3. After cleaning, reassemble impeller into the pump and fasten by turning housing endcap and housing endcap retainer until snug to assure a proper seal. Shaft endcap must be on each end of shaft.

10 Rio Plus pump will not restart if impeller is not positioned or assembled Impeller may need to be replaced periodically to maintain a steady output flow. Rio Plus pump replacement parts, are sold at your local pet dealer or call us, TAAM for more information for purchasing Rio Plus pump replacement Do not tamper with or replace the power cord of this appliance. If the cord is damaged, the appliance should be WARRANTYTAAM warrants that Rio Plus pump is free from defects for a period of 6 months from the initial date of purchase shown on the original cash register receipt. TAAM dis-claims all other warranties of merchantability and/or fitness for a particular purpose. Although this limited warranty may give you specific rights, you may have other rights that may vary from state to state. This warranty is void if the failure of the pump or any part, sealant or component there of is due to (i) misuse, (ii) tampering, (iii) negligence, (iv) misapplication, (v) abuse, (vi) accident and/or (vii) failure to properly (a) maintain, (b) clean, (c) keep pump fully submersed and/or use the pump with a Ground Fault Circuit Interrupter (GFCI).


Related search queries