Example: quiz answers

AquaCell - blog.wavin.com

AquaCell Stormwater Management System Product Description Standard Configuration Extra strong Configuration Geocellular units for detention and infiltration of rainwater. The optimal solution for fast installation and total access for inspection and cleaning. Technical information Standard Height Length Width Displacement Storage Void Ratio Configuration (in) (in) (in) (CF) (CF). SC '' '' '' CF CF SC '' '' '' CF CF SC '' '' '' CF CF SC '' '' '' CF CF SC '' '' '' CF CF SC '' '' '' CF CF SC '' '' '' CF CF SC '' '' '' CF CF Extra Strong Height Length Width Displacement Storage Void Ratio Configuration (in) (in) (in) (CF) (CF). EX '' '' '' CF CF EX '' '' '' CF CF EX '' '' '' CF CF EX '' '' '' CF CF EX '' '' '' CF CF EX '' '' '' CF CF EX '' '' '' CF CF EX '' '' '' CF CF Hydraulic function Water storage AquaCell is a geocellular unit used to build subsurface Void rate for reuse rainwater detention, retention, infiltration and storage 95%.

Wavin recommends a minimum cover of 12 inches over the top of the tank. For details on use in the standard or extra strong versions, or if you need further information, contact your …

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of AquaCell - blog.wavin.com

1 AquaCell Stormwater Management System Product Description Standard Configuration Extra strong Configuration Geocellular units for detention and infiltration of rainwater. The optimal solution for fast installation and total access for inspection and cleaning. Technical information Standard Height Length Width Displacement Storage Void Ratio Configuration (in) (in) (in) (CF) (CF). SC '' '' '' CF CF SC '' '' '' CF CF SC '' '' '' CF CF SC '' '' '' CF CF SC '' '' '' CF CF SC '' '' '' CF CF SC '' '' '' CF CF SC '' '' '' CF CF Extra Strong Height Length Width Displacement Storage Void Ratio Configuration (in) (in) (in) (CF) (CF). EX '' '' '' CF CF EX '' '' '' CF CF EX '' '' '' CF CF EX '' '' '' CF CF EX '' '' '' CF CF EX '' '' '' CF CF EX '' '' '' CF CF EX '' '' '' CF CF Hydraulic function Water storage AquaCell is a geocellular unit used to build subsurface Void rate for reuse rainwater detention, retention, infiltration and storage 95%.

2 Tanks. It's the optimal solution for faster installation and full access to inspection and cleaning activities. Infiltration to recharge groundwater 77 Gallons/. CF Temporary storage to prevent flooding Top Adaptor 10/12 in 10/16 in Base Unit Side Plate Pipe Connector Variable Bottom Plate Accessibility Installation depth by load3. Vertical access 10 in 250 mm Minimum/ Standard Extra strong (Max Burial Depth). Width inspection channel H-10 Traffic Loading 12 in. / ft. 12 in. / ft. 8 in 200 mm (bottom). HS-20 Traffic Loading 184 in / ft. 165 in. / ft Accessible surface area 54%. HS-25 Traffic Loading 30 in / ft. 22 in. / ft. Note: (3) Each project must conduct a stress analysis to ensure the system's stability General based on the acting loads, soil type and water table involved.

3 Wavin recommends a minimum cover of 12 inches over the top of the tank. For details on use in the standard or Material Recycled polypropylene extra strong versions, or if you need further information, contact your Designated Technical Marketing Consultant. Color Black (4) 18 in based on 10 x10 contact area (5) 16 in is based on 9 x9 contact area Connectors Integrated Maximum Installation Depth Standard EN17152-1. H-10 Tra c HS-20 Tra c HS-25 Tra c Weight, pipe connections and 0 ft number of layers ft ft ft ft ft ft ft Base Unit Weight (lbs) 24. Pipes NPS (in) 6 to 24 ft Maximum number of layers ft (with a minimum cover depth 8 layers of 12 in for landscaped areas). ft ft ft ft Performance and installation ft Installation speed1 1500 ft / hour/ per person ft Coupling mechanism Manual Push fit 23 ft Sand, Stone or other approved backfill Bedding material (base).

4 (Compacted and ft ft ft ft leveled material). Standard Extra Strong Minimum depth (base) 4 in Con guration Con guration Percent Compaction (SP)2 90% - 95% - 98%. Note: (1) Measured performance for cell assembly, obtained with material supplies and trained personnel on-site. Based on tank size (20' L x 10' W x 4' H). (2) Percent compaction varies according to the type of loads (no traffic, light traffic and heavy traffic, respectively). AquaCell in the US. Boca Chica, TX | August, 2024 Athens, GA | 2024. Application: Detention under parking lot at carwash Application: Detention system under parking lot Capacity: 2,440 CF Capacity: 24,023 ft3. Assembly time: 1 day Assembly time: 2 days Nashville, TN | 2024 Houston, TX | 2024. Application: Detention system at landscaped area Application: Detention under parking lot Capacity: Tank 1 (7,973 ft3); Tank 2 (7,205 ft3) Capacity: 20,629 CF.

5 Assembly time: Both tanks, 1 day Assembly time: 2 days Contact Joshua Schroeder Technical Sales Manager, Wavin 830-475-5617. Retention and Detention System System Benefits Environmental: Ideal for rainwater reuse. Reduces the water footprint. Does not contaminate the subsoil. Does not alter water characteristics. Low installation impact. Structural: On-site performance is superior to concrete Reuse System and metal. Manual installation, no accessories required. The solution can be tailored to any geometric structure. It is ideal for areas with limited access and heavy rainfall. Access for inspection and cleaning activities. Urban Development: Mitigates the effects of flooding. Ideal for sustainability certifications. Reduces dependence on potable water. Reduces saturation of drainage networks.

6 Infiltration System Alternative source for non-potable uses. Product Quality: Long service life. Lightweight and highly structurally resistant. Large storage capacity: stackable cells. Resistant to water and soil activities.