Example: barber

ASCO SERIES 300 Power Transfer Switches

Business-Critical Continuity ASCO SERIES 300 Power Transfer Switches ASCO< S ERIES 300. Power Transfer Switches for Power Outage Protection. Where would you be It's for this reason that proper voltage and without a constant flow of many businesses and other frequency. This happens in electrical Power ? We often entities have invested in a matter of seconds after take for granted that Power emergency Power backup the Power failure occurs. will always be around when systems. Typically, the sys- When the utility Power has we need it. In reality, Power tem consists of an engine been restored, the ATS will failures are very common.

To avoid any of these power outage problems, simply install a backup generator with an ASCO SerieS 300 Transfer Switch, and your power outage concerns will be a thing of the past. The ASCO S erieS 300 Transfer Switch can be a critical component of a municipal government’s emergency power …

Tags:

  Switch, Generators

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ASCO SERIES 300 Power Transfer Switches

1 Business-Critical Continuity ASCO SERIES 300 Power Transfer Switches ASCO< S ERIES 300. Power Transfer Switches for Power Outage Protection. Where would you be It's for this reason that proper voltage and without a constant flow of many businesses and other frequency. This happens in electrical Power ? We often entities have invested in a matter of seconds after take for granted that Power emergency Power backup the Power failure occurs. will always be around when systems. Typically, the sys- When the utility Power has we need it. In reality, Power tem consists of an engine been restored, the ATS will failures are very common.

2 Generator and an automatic automatically switch the And when the Power goes Transfer switch (ATS) which load back, and after a time out, your business suffers. transfers the load from the delay, it will shut down the Power failures are un- utility to the generator. engine. With an Automatic predictable. They can occur An ATS with built-in Transfer switch , you are at any time and for any control logic monitors your protected 24 hours a day, number of reasons a bolt normal Power supply and seven days a week. of lightning, a Power surge, senses any interruptions. a blackout, an accident or When the utility Power even equipment failure.

3 Fails, the ATS automatically They come without warning starts the engine and and often at the most transfers the load after the inconvenient times. generator has reached 2. Typical Applications Telecom Agriculture Commercial / Retail, Municipal In the telecommunications Maintaining electrical Power is Light Industrial The ASCO SERIES 300 Transfer industry, providing a high level vital to an agriculture opera- The retail industry is very com- switch can be a critical com- of service and dependability is tion. If the flow of Power is petitive. An electrical Power ponent of a municipal govern- crucial. Lost Power means an interrupted, your operation failure can have a dramatic ment's emergency Power interruption in service for your could be at risk unless the impact on a retailer's bottom backup system.

4 Residents of customers and lost business for backup generator is quickly line. If Power is interrupted townships, cities and counties your company. For instance, activated. A prolonged Power during peak shopping times, rely on police, fire, ambu- with cell sites scattered across a outage can affect numerous the effect could be extremely lance/first aid and other critical wide geographical region and in aspects of the operation, from damaging to present and public sector services. An inter- many remote areas, the chances housing and feeding livestock future business. A Power inter- ruption in Power would affect of an interruption in Power are to processing and producing ruption will not only suspend the ability of emergency servic- increased, making Automatic the end product.

5 With an shopping, it can also create safe- es to effectively respond to the Transfer Switches a valuable ASCO SERIES 300 Transfer ty problems, result in lost trans- needs of the community. resource at each location. To switch , Power will auto- action data, lost account infor- When time is a critical factor, maintain dependable service, matically be transferred over mation and damage to data such as when responding to a each cell site must be monitored to your backup generator, collection equipment. In addi- fire alarm or an emergency 24 hours a day. This can be eliminating the need to tion, retailers who rely on call, an ASCO SERIES 300.

6 Very difficult without some manually switch from utility to controlled climates to protect Transfer switch can be a life- type of remote monitoring and generator. When Power is valuable inventory could suffer saver, switching Power to the testing capability. The SERIES 300 restored, the ASCO SERIES 300 even greater losses, especially backup generator. While not all Transfer switch , combined with Transfer switch will, after an if the Power failure occurs at a municipal services are a matter ASCO's monitoring and control adjustable time delay to allow time when no one is available to of life and death, they are management system, is a cost- for utility stabilization, auto- rectify the situation.

7 To avoid always expected to be there. effective, packaged solution matically switch the load back any of these Power outage which can help meet both of to the utility service. problems, simply install a back- these challenging objectives up generator with an ASCO. without a major investment at SERIES 300 Transfer switch and each cell site. With ASCO's Power outage concerns will be connectivity solutions you can a thing of the past. remotely monitor and control numerous sites from around the corner or around the world. 3. ASCO. <. SERIES 300 Power Transfer Switches Maximum Reliability & Excellent Value With a SERIES 300 Transfer switch , you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually every major technological advance in the Transfer switch industry.

8 The ASCO SERIES 300 was designed for one purpose to automatically Transfer critical loads in the event of a Power outage. Each and every standard component was designed by ASCO engineers for this purpose. The rugged construction and proven performance of the ASCO. SERIES 300 assure the user of many years of complete reliability. The SERIES 300 is even designed to handle the extraordinary demands placed on the switch when starting or restarting stalled motors and switching high inrush loads. ASCO's SERIES 300 modular, compact design makes it easy to install, inspect and maintain. All parts are accessible from the front so switch contacts can be easily inspected.

9 Features Fig. 1: ASCO Power Transfer switch rated The SERIES 300 is listed to UL 1008 standard for Transfer switch 200 amperes shown in Type 3R enclosure Equipment and CSA standard for automatic Transfer Switches . Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code (NEC) Articles 700, 701 and 702. There's no danger of the SERIES 300 ATS. 30 through 3000 amps in a compact design. transferring loads to a dead source because Available to 600 VAC, single or three phase. the unique ASCO single-solenoid operator True double-throw operation: The single solenoid design is inherently inter derives Power to operate from locked and prevents contacts from stopping between sources the source to which the load is being or from being in contact with both sources at the same time.

10 Transferred. Easy-to-read flush-mounted control and UL Listed Withstand & Close-On Ratings display panel provides LED indicators Available Symmetrical Amperes RMS for switch position and source availability. It also includes test and time-delay bypass switch Ratings When Used Switches as standard features. amps Maximum When Used With Current With Specific Standard engine exerciser for weekly Voltage Limiting Fuses Circuit Breakers automatic testing of engine generator set 30 100,000 480v/60Hz 10,000 with or without load. 70 - 200 200,000 480v/60Hz 22,000 Adjustable time-delay feature prevents switch 230 100,000 480v/60Hz 42,000 from being activated due to 260, 400 200,000 480v/60Hz 42,000 momentary utility Power outages and 600 200,000 600v/60Hz 42,000 generator dips.