Example: air traffic controller

ASTM A53 Type E, Grade A Pipe

astm A53 Type E, Grade A pipe SUBMITTAL DATA SCOPE Covers black and hot-dipped galvanized Electric Resistance Welded Grade A pipe . pipe is intended for mechanical and pressure applications and is acceptable for ordinary uses in steam, water, gas and air lines. pipe is suitable for welding, threading, grooving and bending. pipe is not intended for flanging. Produced to latest revisions of astm A53/A 53M, and ASME pipe is also UL, ULC listed, sizes 1/2 to 6 S40, and FM approved 1 to 6 S40 (not included 3 , 5), for use in Fire Sprinkler pipe applications. HOT-DIPPED GALVANIZED The average weight of zinc coating shall be not less than oz. per sq. ft. of surface (inside and outside) When galvanized pipe is bent or otherwise fabricated to a degree which causes zinc coating to stretch or compress beyond the limit of elasticity, some flaking of the coating may occur. Produced to the latest revisions of astm 123/A. HYDROSTATIC TESTING and NONDESTRUCTIVE ELECTRIC TESTING Hydrostatic test pressures for plain-end pipe are indicated below.

ASTM A53 Type E, Grade A Pipe SUBMITTAL DATA SCOPE Covers black and hot-dipped galvanized Electric Resistance Welded Grade A pipe. Pipe is intended for mechanical and pressure applications and

Tags:

  Types, Astm, Grade, Pipe, Astm a53 type e, Grade a pipe

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of ASTM A53 Type E, Grade A Pipe

1 astm A53 Type E, Grade A pipe SUBMITTAL DATA SCOPE Covers black and hot-dipped galvanized Electric Resistance Welded Grade A pipe . pipe is intended for mechanical and pressure applications and is acceptable for ordinary uses in steam, water, gas and air lines. pipe is suitable for welding, threading, grooving and bending. pipe is not intended for flanging. Produced to latest revisions of astm A53/A 53M, and ASME pipe is also UL, ULC listed, sizes 1/2 to 6 S40, and FM approved 1 to 6 S40 (not included 3 , 5), for use in Fire Sprinkler pipe applications. HOT-DIPPED GALVANIZED The average weight of zinc coating shall be not less than oz. per sq. ft. of surface (inside and outside) When galvanized pipe is bent or otherwise fabricated to a degree which causes zinc coating to stretch or compress beyond the limit of elasticity, some flaking of the coating may occur. Produced to the latest revisions of astm 123/A. HYDROSTATIC TESTING and NONDESTRUCTIVE ELECTRIC TESTING Hydrostatic test pressures for plain-end pipe are indicated below.

2 (PSI). Test pressures shall be maintained for a minimum of 5 seconds. NPS S40 S80 NPS S40 S80 1/2 700 850 2 1/2 2500 2500 700 850 3 2220 2500 1 700 850 3 1/2 2030 1 1200 1800 4 1900 1 1200 1800 5 1670 2 2300 2500 6 1520 Nondestructive electric testing of the weld seam is required on each length of ERW pipe NPS and larger. END FINISH Plain end: NPS and larger: ends are beveled top a angle of 30 , + 5 0 with a root face of 1/16 1/32 Threaded: To ANSI Standard Couplings: To astm Standard A865 CHEMICAL REQUIREMENTS Composition, max % Carbon: , Manganese: , Phosphorus: , Sulfur: , *Copper: , *Nickel: *Chromium: , *Molybdenum: , *Vanadium *The combination of these five elements shall not exceed TENSILE REQUIREMENTS Tensile Strength: 48000 Psi (330 Mpa) minimum Elongation: Refer to astm A53 table Yield Strength: 30000 Psi (205 Mpa) minimum FLATTENING TEST NPS and greater: As a test for quality of the weld, position of the weld at 90 from the direction of force and flatten until the OD is 2/3 of the original outside diameter.

3 No cracks shall occur along the inside or outside surface of the weld. DIMENSIONS AND WEIGHTS (Black plain end) NPS OD inches S40 wall inches S40 weight Lb/ft S80 wall inches S80 weight Lb/ft NPS OD inches S40 wall inches S40 weight Lb/ft S80 wall inches S80 weight Lb/ft 1/2 2 1/2 .203 3 .216 1 3 .226 1 4 .237 1 5 .258 2 .154 6 .280 * OD and Wall are specified, Weight is nominal PERMISSIBLE VARIATIONS IN WALL THICKNESS, IN OUTSIDE DIAMETER, IN WEIGHT PER FOOT Minimum wall thickness at any point shall not be more than under nominal wall thickness specified. pipe Diameter NPS 1 1/2 and under: 1/64 in. pipe Diameter NPS 2 and over: 1% pipe weight per foot shall not vary more than 10% from the standard specified PRODUCT MARKING Each length of pipe NPS and larger is continuously stenciled to show the manufacturer name, Made in Canada , the Grade of pipe ( astm A53), the type of pipe (E for electric-resistance welded, A for Grade A), the size (S40 for nominal), length, Galvanized lot number and date.

4 Stencil markings indicate UL, ULC listing (ULC, UL LISTED 22ZL STEEL SPRINKLER pipe ) and FM approved for sizes mentioned in scope for use in Fire Sprinkler pipe applications. Bar coding is acceptable as a supplementary identification number. All information contained herein is accurate as know at the time of publication. Nova Tube Inc. reserves the right to change product specifications without notice and without incurring obligation (April 5, 2011) Prepared by: Rapha l Ciccariello, eng. Nova Tube Inc. Tel : +1 514-789-0511 5870, rue St-Patrick Toll free : 1-866-953-7751 Montr al, Fax : +1 514-366-3176 Canada, H4E 1B3