Transcription of Atlas Copco - airserviceinc.com
1 GA 200-500 / GA 315 VSD / GR 110-200 Atlas CopcoOil-injected rotary screw compressors50-60 Hz4 The Total Energy Saving shortest route to maximizing your profitability is to minimize operational cost. Because energy consumption is the major factor in a compressor s life cycle cost, the focus in the design of the Atlas Copco GA and GR compressors is on saving energy in every conceivable way. This focus is the basis for a total product development concept that encompasses every stage of R&D, manufacturing, installation and after sales thorough needs assessmentReal savings rely on facts.
2 Atlas Copco consultants assess the air demand profile of your application and suggest the best compressor selection for the right core technologyAtlas Copco masters every compression principle and provides the most energy ef ficient technology for the required pressure and best drive arrangementFixed speed machines are fine when they can run at full load most of the time. But when air demand fluctuates, the Variable Speed Drive can achieve substantial savings of up to 35%.The integrated designInternal piping, integral air dryer, integrated Variable Speed Drive, 10 0% matched components, consolidated only way to ensure total reliabilit complete solutionCompressor, dryer, drive, filters, control all carry the same mark of qualit y.
3 The Atlas Copco experienced partnerAtlas Copco is the world leader in compressed air technology, with over 10 0 years of experience in air compression lowesT operaTing cosTThe highesT reliabiliTyenergy savings with VSDinvestment maintenanceenergy 4An energy efficient machine saves money only if it runs reliably around the clock. And not just today, but day after day, year after year; with minimal service interventions and long overhaul over a century, Atlas Copco has been building machines that stand the test of time.
4 With the proven GA/GR compressors, reliability has never been so combined with the Total Reliability conceptThe fully optimized systemA multi- compressor installation can be centrally controlled, to achieve a tight pressure band and the lowest overall energy trouble-free installation & commissioningAn Atlas Copco GA compressor is truly plug-and-play. Put the machine on a flat floor, connect the power line and the compressed air push the star t but recoveryHeat from the compression process can be recovered and put to good use in endothermic processes, heating of buildings professional follow-upAn Atlas Copco Service Contract will assure you of the correct preventive maintenance.
5 Immediate response and genuine spare par all over the t power 10 0%Recoverable energy 9 4%Radiant losses 2%Remaining heat in compressed air 4%444 Proven technology in one packageThe GA 200-500 and GR 110-200 range comprises a series of no-nonsense machines with a robust and reliable design, easy to service and environmentally friendly. They are the culmination of decades of continuous improvement, radical innovation and interaction with the this range, the Total Energy Saving Concept takes solid form in the GA 315 VSD-FF compressor .
6 It integrates a complete quality compressed air system in a compact package, featuring the ID dryer and the low energy Variable Speed Standard G compressor packages and Full Feature (FF) units all vital components and standard options integrated, for a complete all-in-one installation4 Complete, ready-to-use compressor package4 Easy, low cost installation no foundations4 True performance according to ISO 1217, Annex C, ed. 34 Cost-effective and reliable Elektronikon monitoring and control system4 Single-stage, twin-element and two-stage HP versions4 Proven reliability4 Straightforward and minimal maintenance4 Operator and service-friendly4 Silenced package environment friendly4 Optional energy recovery system4 Water and aircooled versions 4 A wide range of pressure and capacity variants4 Backed by a global sales and service organizationExcellence by designGA 200-315 FF, GA 315 VSD-FF, GA 315-500.
7 GR 110-200 FFCapacity range (50 & 60 Hz): air and watercooled versionsVSD: Variable Speed Drive / FF: Full data pages for range 04244 0 08 4 8l/scfm06 0 0127280 0169610 0 02120120 025 4 414 0 02968GA 200-315GA 315 VSDGA 315-500GR 110-200 GR 110-200 GR 200 FFTwo-stage high pressure versionGA 250 FFTwin element versionGA 315 VSD-FFVariable Speed Drive versionGA 400 Twin element versionGA 315 VSDGA 315-500GA 200-31544A complete scope to meet every needIncluded as standardAvailable options Air intake filter Air intake valve (not on VSD units) Aftercooler/Oilcooler (air or watercooled)
8 Cooling fan for aircooled units Ventilation fan for watercooled units Water separators Oil filters Complete air/oil/water circuit TEFC, Class F drive motor Built-in electrical starters Flexible vibration dampers Air/oil separator Elektronikon control system Full load/no load regulation system (not on VSD units) Silencing canopy Single point inlet and outlet connections Structural steel skid no foundations neededMost features are included as standard. Some applications may need or benefit from additional 200-315 GR 110-200 GA 315 VSDGA 315-500 Full Feature.
9 Integrated ID refrigerant dryer (1) na Integrated DD pre-filter (only with integrated dryer) (2) na Energy recovery na Modulation control na na OSD oil separator (for pack/FF units) (3) Oil containing frame na Electronic water drain (EWD) (2) (4) Heavy duty air intake filter na HAT version (122 F ambient temperature) (5) na na na Phase sequence relay na PT 1000 thermal protection for main motor na Anti condensation heater for main motor na HD oil - 8000 h oil (instead of RIF oil) (4) NPT connections (6) na na ANSI flanged connections (7)
10 Na Anchor pads Performance test certificate Witnessed performance test certificate Material test certificate for pressure vessel approvals Sea-worthy packaging Rain protection na IT/NT system na na na Tube cooler na na SPM monitoring (1) Integrated VSD refrigerant dryer(2) Only for GR 200 psi(3) Effluent purity of 10 mg oil/liter(4) Standard(5) Not available for 200 psig bar versions and FF units(6) Applies only to GA 90-160(7) Applies only to GA 200-315na: not applicable4123456GA 250 - 315 FF twin element 250 FFAircooled Full Feature modelQuality air with low oil content4 three step air-oil separation (centrifuge, gravity, filter)4 oil content.