1 | Page Firestone Attachment Guide November 29, 2021 Attachment Guide & Supplemental Increased Wind Speed Warranty Attachment Guide November 2021 NOTE: The contents of this Guide are considered accurate at time of posting. All information contained within should be validated for accuracy as it relates to specific project conditions or requirement. Specific codes, uplifts or other factors may result in changes to the information contained within this document. Validate all specific conditions with your Building Systems Advisor prior to its use. 2 | Page Firestone Attachment Guide November 29, 2021 Contents Introduction .. 5 Substrate and Substrate Requirements.

Lay out strips over insulation; attach strip using plate or battens, place membrane over the strips. Substrate and Substrate Requirements General 1. The Firestone roof system depends on a suitable substrate to perform its intended function of weatherproofing the ... Plank minimum ¾", Plywood minimum 15/32" or OSB minimum 7/16" thickness ...

Tags:

  Attachment, Strips, Plank

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Attachment Guide Supplemental Increased Wind Speed ...

1 1 | Page Firestone Attachment Guide November 29, 2021 Attachment Guide & Supplemental Increased Wind Speed Warranty Attachment Guide November 2021 NOTE: The contents of this Guide are considered accurate at time of posting. All information contained within should be validated for accuracy as it relates to specific project conditions or requirement. Specific codes, uplifts or other factors may result in changes to the information contained within this document. Validate all specific conditions with your Building Systems Advisor prior to its use. 2 | Page Firestone Attachment Guide November 29, 2021 Contents Introduction .. 5 Substrate and Substrate Requirements.

2 5 General .. 5 Minimum Fastener Pullout Resistances for Specific System .. 6 Criteria for Field Testing Mechanical Attachment to Various Deck Substrates .. 6 Building Configuration .. 7 Large Wall Opening Enhancement .. 7 Roof Zone Definition Factory Mutual (FM) .. 8 Roof Zone Layout Based on Building Height .. 8 Roof Elevation 9 Prescriptive Enhancement Options: Perimeter and Corner .. 9 Adhered Membrane Insulation Enhancements (choose one): .. 9 Mechanically Attached Membrane Membrane Securement Enhancements In Seam .. 9 Factory Mutual (FM) Invisiweld Attachment Rates .. 10 Invisiweld Attached Membrane Membrane Securement Enhancements .. 10 Base Sheet Attachment Over FM Approved Deck Types.

3 10 Base Sheet Mechanically Attached (choose one): .. 10 Mechanically Attached Membrane Preliminary Insulation Securement .. 11 ASCE 7 Basic Wind Speeds for Risk/Occupancy Category .. 12 ASCE - American Society of Civil Engineers - Roof Zones .. 12 ASCE 7-10 (IBC 2015/2012) .. 12 ASCE 7-10 Perimeter and Corner Definition - Examples .. 12 ASCE 7-16 (IBC 2018) .. 13 ASCE 7-16 Perimeter and Corner Definition Examples .. 13 Insulation Attachment .. 15 General .. 15 Attachment .. 15 Multiple Layers of Insulation .. 15 Attachment of Insulation to Substrate Adhered Membrane .. 15 Mechanical Attachment of Insulation to Substrate Mechanically Attached Membrane .. 16 Attachment of Vacuum Insulated Panels (VIPs) Adhered Membrane Only.

4 17 Insulation Mechanical Attachment Patterns .. 17 Insulation Adhesive Attachment Pattern .. 19 Criteria for Field Testing Insulation Adhesives for Adhesion to Deck Substrates .. 20 3 | Page Firestone Attachment Guide November 29, 2021 When Specified Uplifts Are Required .. 20 Warranty Purposes with No Specified Uplift .. 20 Retarders - Air and Vapor Definition .. 21 Vapor Retarder (Barrier) .. 21 Air Barrier (Retarder) .. 21 Attachment Rate Requirements for Plate Bonded Systems with an Air Barrier .. 22 Modified Bitumen Base Sheet Attachment .. 23 General .. 23 Base Sheet Attachment with any Modified Bitumen Base Sheet .. 23 Base Sheet Attachment , Coiled Metal Batten, with a SBS Torch Cap .. 24 Base Sheet Attachment , MB 2" Barbed Plates, with a SBS Torch Cap.

5 24 Single-Ply Membrane Attachment .. 25 Acceptable Fastener and Plate Guidelines .. 25 Perimeter Enhancements .. 28 Peel Stops .. 29 Factory Mutual (FM) Attachment Layout Examples .. 29 RubberGard EPDM .. 29 UltraPly TPO .. 30 Firestone PVC and PVC KEE .. 31 Invisiweld .. 31 Layouts in Chart Form Firestone Warranty Requirements .. 31 InvisiWeld Attachment .. 34 General .. 34 Induction welded membrane: .. 35 Heat welded membrane seams: .. 35 Invisiweld Fastener Patterns: .. 35 Invisiweld Warranty Requirements: .. 37 Invisiweld Enhancement Requirements: .. 37 Metal Building Re-Cover (MBR) Invisiweld Attachment Rates Standard Warranty .. 39 Metal Building Re-Cover Mechanically Attached FM Enhancement Options.

6 40 Factory Mutual Loss Prevention Data Sheet 1-31 .. 40 Standing Seam Roof (SSR) Factory Mutual (FM) Inseam Enhancement Options .. 40 Firestone Increased Wind Speed Warranty Minimum Attachment Rate Guide .. 42 Alaska, Hawaii and International Projects .. 42 Metal Roofing .. 42 4 | Page Firestone Attachment Guide November 29, 2021 Asphalt/Mod-Bit 42 General Notes .. 43 Edge Metal Requirements .. 43 Hurricane-Prone Regions and Special Wind Regions .. 44 Increased Wind Speed Warranty Attachment Requirements .. 45 Cover Board/Insulation Attachment Rates - Adhered Single-Ply Membrane Roofing Systems .. 45 Additional Notes: .. 46 Ballasted Roofing Systems .. 46 Stone, Firestone Ballast Pavers and Heavy-Weight (90 lbs) Paver Ballast.

7 46 Half Sheet Information .. 47 Warranty .. 47 UltraPly TPO Mechanically Attached or Adhered Membrane Options .. 47 Increased Wind Speed System Options .. 47 UltraPly TPO Membrane Mechanically Attached Requirements .. 48 TPO - Steel/Concrete - 22 ga Steel Deck or 2,500 psi Structural Concrete Decks .. 48 TPO - Wood Decks .. 49 TPO - LWC over Steel/Structural Concrete - UltraPly TPO Membrane Mechanically .. 50 TPO - Invisiweld Attachment Requirements .. 50 Firestone PVC and PVC KEE Mechanically Attached or Adhered Membrane .. 51 Increased Wind Speed System Options .. 51 Firestone PVC or PVC KEE Membrane Mechanically Attached Requirements .. 51 PVC or PVC KEE Min. 22 ga Steel Deck or 2,500 psi Structural Concrete Decks.

8 51 PVC and PVC KEE - Wood Decks .. 52 PVC and PVC KEE - LWC over Steel/Structural Concrete - Mechanically Attached .. 53 PVC and PVC KEE - Invisiweld Attachment Requirements .. 53 RubberGard MAX EPDM Mechanically Attached or Adhered Membrane Options .. 54 Increased Wind Speed System Options .. 54 RubberGard MAX EPDM Membrane Mechanically Attached Requirements .. 54 EPDM - Steel/Concrete - 22 ga Steel Deck or 2,500 psi Structural Concrete Decks .. 54 EPDM - Wood Decks .. 55 EPDM - LWC over Steel/Structural Concrete - RubberGard EPDM Membrane Mechanically Attached into min. 22 ga Steel Pan/Deck or 2,500 psi Structural Concrete .. 56 Base Sheets Mechanical Attachment Requirements .. 56 LWC - Base Sheet Attachment Rates.

9 56 5 | Page Firestone Attachment Guide November 29, 2021 Introduction The purpose of this Guide is to reinforce installation techniques. The following Guide is a supplement to be used in conjunction with the other technical information located on the Firestone Building Products website. Reference to the specific Design Guide , Quick Specifications, Application Guide , Details, Technical Information Sheets (TIS), and other Specifications is necessary to ensure that the finished roof system is installed in compliance with Firestone requirements. The following document outlines the required Attachment rates and conditions that Firestone Building Products looks for to issue a warranty.

10 When the project requires specific codes and/or uplifts to be met the Attachment rates below may not be appropriate. Review of the specific project conditions and specifications should be completed, and all pertinent information must be provided to Firestone Building Products prior to the project being bid or installed. Failure to do so may result in required changes to the bids, products used, installation and/or possible denial of warranty coverage. Not all conditions are covered in this document. Please contact your Firestone Sales Representative or your Regional Building System Advisor for conditions or information not found in this document. Due to unknown variables associated with each building structure, Firestone suggests a licensed engineer to verify all Attachment rates are appropriate for the specific project requirements.


Related search queries