Plugs AND RECEPTACLES: ATEX/IECEX INCREASED SAFETYV isit our website at or contact us at (800) 621-1506. November 2016528 ATX PRE Series 16 Amp Plugs and SocketsIncreased SafetyATEX/IECEx:Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09/10 Applications Plugs and receptacles are used with portable or stationery electrical equipment such as: Lighting systems Conveyors Heaters Motor generators Air conditioning equipment Compressors Pumps For use in corrosive atmospheres and installations in Zone 1 and 2 and 21 and 22 of the oil and gas industry; such as: Refineries Chemical and petrochemical plants Pipelines Loading docks Onshore and offshore drilling platformsFeatures Plug and socket system is designed with a safe disconnect mechanism to insure maximum hazardous location protection: The contact separation is in a flameproof chamber The automatic electrical disconnection of each phase is contained in a second flameproof chamber Short circuit protection is 20 kA, while normal reference is 10 kA.

PLUGS AND RECEPTACLES: ATEX/IECEX INCREASED SAFETY Visit our website at www.emerson.com or contact us at (800) 621-1506. © November 2016 528 ATX™ PRE Series 16 Amp Plugs and Sockets

Tags:

  Series, Pre series 16 amp plugs and sockets, Plugs, Sockets

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ATX PRE Series 16 Amp Plugs and Sockets - Emerson

1 Plugs AND RECEPTACLES: ATEX/IECEX INCREASED SAFETYV isit our website at or contact us at (800) 621-1506. November 2016528 ATX PRE Series 16 Amp Plugs and SocketsIncreased SafetyATEX/IECEx:Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09/10 Applications Plugs and receptacles are used with portable or stationery electrical equipment such as: Lighting systems Conveyors Heaters Motor generators Air conditioning equipment Compressors Pumps For use in corrosive atmospheres and installations in Zone 1 and 2 and 21 and 22 of the oil and gas industry; such as: Refineries Chemical and petrochemical plants Pipelines Loading docks Onshore and offshore drilling platformsFeatures Plug and socket system is designed with a safe disconnect mechanism to insure maximum hazardous location protection: The contact separation is in a flameproof chamber The automatic electrical disconnection of each phase is contained in a second flameproof chamber Short circuit protection is 20 kA, while normal reference is 10 kA.

2 Different voltages are color coded for easy identification. The receptacles are keyed to accept only ATX Plugs (other Plugs can not be inserted). ATX Plugs can be used in non-hazardous IEC 309 Sockets . Operating temperature of -40 C to +55 C (-40 F to +131 F)Standard Materials Wall Socket for 2P - 2P+E - 3P: high impact resistance polycarbonate Wall Socket for 3P+E - 3P+N+E: high impact resistance fiberglass reinforced polyester Plug, mobile socket and flush socket: polyamideATEX/IECEx Certifications and Compliances Certification Type PCX (Plug, socket and mobile socket) Gas: Zones 1 and 2 Conforming to ATEX 94/9/CE: II 2 G Type of Protection: Ex de IIC Temperature Class: T6 for Ta +40 C (-40 F) and T5 for +55 C (+131 F) Dust: Zones 21 and 22 Conforming to ATEX 94/9/CE: II 2 D Type of Protection: Ex tD A21 Surface Temperature: T68 C (T154 F) Impact Resistance (shock).

3 IK10 (Polyester) and IK09 (Polyamide) CE Declaration of Conformity: 50228 ATEX Certificate: LCIE 02 ATEX 6068 IECEx Certificate: IECEx LCI Certification Type PCX/EN (Flush socket) Gas: Zones 1 and 2 Conforming to ATEX 94/9/CE: II 2 G Type of Protection: Ex de IIC Temperature Class: T6 for Ta +40 C (-40 F) and T5 for +55 C (+131 F) Dust: Zones 21 and 22 Conforming to ATEX 94/9/CE: II 2 D Type of Protection: Ex tD A21 Surface Temperature: T68 C (T154 F) Impact Resistance (shock): IK09 (Polyamide) CE Declaration of Conformity: 5C214 ATEX Certificate: LCIE 02 ATEX 0001U IECEx Certificate: IECEx LCI Ambient Temperature: -40 C Ta +55 C (-40 F Ta +131 F) Index of Protection according EN/IEC 60529: IP66 EURASEC Certification Certification Type PCX (Plug, socket and mobile socket) EURASEC N TC RU C-FR.

4 ГБ Certification Type PCX/EN (Flush socket) EURASEC N TC RU C-FR.ГБ Certification Certification Type PCX (Plug, socket and mobile socket) INMETRO Certificate: Certification Type PCX/EN (Flush socket) INMETRO Certificate: PlugWall Mounting SocketMobile SocketFlush Socket INMETRO certification available on special request only. Contact your local sales representative for more DataBreaking CapacityAC 34 kW 220 kW 240 kW 380 kW 415 VICC20 kAPLUGS AND RECEPTACLES: ATEX/IECEX INCREASED SAFETYV isit our website at or contact us at (800) 621-1506. November 2016529 ATX PRE Series 16 Amp Plugs and SocketsIncreased SafetyWall Mounting SocketPlugMobile SocketFlush Socket Three M20 threaded entries (one on the top and two on the bottom).

5 Supplied with one M20 cable gland to mm ( to ) and two M20 blanking Plugs . Terminal capacity 2 x 4 mm2 ( x in2). Can be through-wired. Fitted with three linked earth terminals. One PG16 integrated cable gland to mm ( to ). Terminal capacity mm2 ( in2). One PG16 integrated cable gland to mm ( to ). Terminal capacity 2 x 4 mm2 ( x in2). Terminal capacity 2 x 4 mm2 ( x in2).ATEX/IECEx:Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09/10 Catalog Numbering Guide - IECEx Internationally Certified Plugs and ReceptaclesPRE216 RPIECEx Series :PRE - PRE SeriesZone 1, 2, 21 and 22 ATEX / IECExAmps:16 - 16 AVoltage:P - 20 - 25 Vac 50/60 HzW1 - 20 - 50 VdcW - 40 - 50 Vac 50/60 HzY - 100 - 130 Vac 50/60 HzB - 200 - 250 Vac 50/60 HzR - 380 - 415 Vac 50/60 HzN - 480 - 500 Vac 50/60 HzG - 50 - 500 Vac 300 to 500 HzPin Configuration:2 - 2P3 - 2P+E4 - 3P+E5 - 3P+N+E6 - 3 PEquipment:P - PlugR - Receptacle (Wall Mounting)M - Mobile SocketF - Flush SocketELV: Extra Low VoltagePurpleWhiteWhite20/25 Vac20/50 Vdc40/50 VacLV.

6 Low VoltageYellowBlueRedBlackGreen100/130 Vac200/250 Vac380/415 Vac480/500 Vac50/500 Vac (300 to 500 Hz) Plugs AND RECEPTACLES: ATEX/IECEX INCREASED SAFETYV isit our website at or contact us at (800) 621-1506. November 2016530 ATX PRE Series 16 Amp Plugs and SocketsIncreased SafetyATEX/IECEx:Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09/10 Catalog NumberDescriptionPin ConfigurationWeight kg (lb)Volume dm3 (in3)Extra Low Voltage: ELV20/25 Vac 50/60 Hz PurpleWall Socket2 Ppolarization ( ) ( ) ( ) ( )PRE216 PPMobile ( ) ( )PRE216 MPFlush ( ) ( )PRE216 FPWall Socket2P+ ( ) ( ) ( ) ( )PRE316 PPMobile ( ) ( )PRE316 MPFlush ( ) ( )PRE316 FPWall Socket3 Ppolarization ( ) ( ) ( ) ( )PRE616 PPMobile ( ) ( )PRE616 MPFlush ( ) ( )PRE616FP20/50 Vdc WhiteWall Socket2 Pauxiliarytab 10hpolarization ( ) ( ) ( ) ( )PRE216PW1 Mobile ( ) ( )PRE216MW1 Flush ( ) ( )PRE216FW140/50 Vac 50/60 Hz WhiteWall Socketpolarization ( ) ( ) ( ) ( )PRE216 PWMobile ( ) ( )PRE216 MWFlush ( ) ( )PRE216 FWWall Socket3 Pauxiliarypin 12hpolarization ( ) ( ) ( ) ( )PRE616 PWMobile ( ) ( )PRE616 MWFlush ( ) ( )

7 PRE616 FWLow Voltage: LV100/130 Vac 50/60 Hz YellowWall Socket2P+EL/+ ( ) ( ) ( ) ( )PRE316 PYMobile ( ) ( )PRE316 MYFlush ( ) ( )PRE316FY200/250 Vac 50/60 Hz BlueWall Socket2P+E6hL/+ ( ) ( ) ( ) ( )PRE316 PBMobile ( ) ( )PRE316 MBFlush ( ) ( )PRE316 FBPLUGS AND RECEPTACLES: ATEX/IECEX INCREASED SAFETYV isit our website at or contact us at (800) 621-1506. November 2016531 ATX PRE Series 16 Amp Low Voltage Plugs and SocketsIncreased SafetyATEX/IECEx:Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09/10 Catalog NumberDescriptionPin ConfigurationWeight kg (lb)Volume dm3 (in3)Low Voltage: LV200/250 Vac 50/60 Hz BlueWall Socket3P+E9hL1L2L3key ( ) ( ) ( ) ( )PRE416 PBMobile ( ) ( )PRE416 MBFlush ( ) ( )PRE416 FBWall Socket3P+N+E (1)L1L2L3N9h (1) 120/208 V - 144/250 Vac 50/60 ( ) ( ) ( ) ( )PRE516 PBMobile ( ) ( )PRE516 MBFlush ( ) ( )PRE516FB380/415 Vac 50/60 Hz RedWall Socket3P+ ( ) ( ) ( ) ( )PRE416 PRMobile ( ) ( )PRE416 MRFlush ( ) ( )PRE416 FRWall Socket3P+N+E (2)L1L2L3N6h (2) 200/346 V - 240/415 Vac 50/60 ( ) ( ) ( ) ( )PRE516 PRMobile ( ) ( )PRE516 MRFlush ( ) ( )PRE516FR480/500 Vac 50/60 Hz BlackWall Socket3P+ ( ) ( ) ( ) ( )PRE416 PNMobile ( ) ( )PRE416 MNFlush ( ) ( )PRE416FN50/500 Vac 300/500 Hz GreenWall Socket3P+N+ ( ) ( ) ( ) ( )

8 PRE516 PGMobile ( ) ( )PRE516 MGFlush ( ) ( )PRE516 FGAccessoriesDescriptionM5 earth stud with black neoprene sealing washer and green/yellow earth conductor, length 300 mm ( )PREESTM20M20 earth continuity adaptor with black neoprene sealing washer and green/yellow earth conductor, length 300 mm ( )PREECAM20 Plugs AND RECEPTACLES: ATEX/IECEX INCREASED SAFETYV isit our website at or contact us at (800) 621-1506. November 2016532 ATX PRE Series 16 Amp Plug and Socket Increased SafetyATEX/IECEx:Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09/10 Dimensions in Millimeters (Inches)16A 2P 2P+E 3P VersionsWall Mounting mm( ) mm( ) mm( ) mm( ) mm( ) mm( ) mm ( ) mm ( ) mm( ) mm( ) mm ( ) mm( ) mm( )Mobile SocketsCan be mounted on panel - mm ( ) thickness maximumFlush mm( ) mm( )54 mm( ) mm( ) mm( ) mm( ) mm( ) mm( ) mm( )210 mm ( ) mm( ) mm( ) mm( ) mm( ) mm ( ) mm( ) mm( ) mm( ) mm( ) mm16A 3P+E 3P+N+E VersionsWall Mounting mm( ) mm( ) mm( ) mm ( ) mm ( ) mm( ) mm( )Fix.

9 Mm( )BCAD imensions in Millimeters (Inches)ABC3 P + ( ) ( ) ( )3 P + N + ( ) ( ) ( )Mobile SocketsCan be mounted on panel - mm ( ) thickness maximumFlush mm( ) mm( ) mm( ) mm( ) mm ( ) mm( ) mm( ) mm( ) mm( ) mm( ) mm( ) mm( ) mm( ) mm( ) mm ( ) mm( ) mm( ) mm( )