AURORA ONE AND TWO STAGE CONDENSATE …

AURORA 210 SerieSONE AND TWO STAGE CONDENSATE pumps 2122 ONE AND TWO STAGE CONDENSATE PUMPSAURORA 210 SerieSOne and Two STAGE CONDENSATE PumpsCapacities to 150 GPMH eads to 270 FeetTemperatures to 190 FIntroductionCondensate units provide for an automatic return of hot water condensation from radiators, coils, pipe, etc., to high- or low-pressure boilers. They are also used in industrial complexes for returning liquids to overhead storage tanks of gravitational circulating systems as well as many other unique uses. CONDENSATE return requirements call for a system that will provide uninterrupted service for single or multiple boiler installations. AURORA packaged systems deliver those values that you need and expect. Quality features include a steel receiver, float switch and pumps all completely assembled. In AURORA s design, the pumps , support and piping are mounted beneath the receiver on a common steel base.

2 OE AD WO AGE CODEAE PUMP AURORA ® 210 SerieS One and Two Stage Condensate Pumps Capacities to 150 GPM Heads to 270 Feet Temperatures to 190° F Introduction Condensate units provide for an automatic return of hot water condensation from radiators, coils, pipe, etc., to high- or low-pressure boilers.

Tags:

  Pumps, Stage, Condensates, One and two stage condensate, One and two stage condensate pumps

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of AURORA ONE AND TWO STAGE CONDENSATE …

1 AURORA 210 SerieSONE AND TWO STAGE CONDENSATE pumps 2122 ONE AND TWO STAGE CONDENSATE PUMPSAURORA 210 SerieSOne and Two STAGE CONDENSATE PumpsCapacities to 150 GPMH eads to 270 FeetTemperatures to 190 FIntroductionCondensate units provide for an automatic return of hot water condensation from radiators, coils, pipe, etc., to high- or low-pressure boilers. They are also used in industrial complexes for returning liquids to overhead storage tanks of gravitational circulating systems as well as many other unique uses. CONDENSATE return requirements call for a system that will provide uninterrupted service for single or multiple boiler installations. AURORA packaged systems deliver those values that you need and expect. Quality features include a steel receiver, float switch and pumps all completely assembled. In AURORA s design, the pumps , support and piping are mounted beneath the receiver on a common steel base.

2 As your heating system grows, the receiver design will allow you to convert from simplex to duplex. Just add a pump and pipe it up! In a duplex system, single pump operation provides service when capacity and demand call for normal service. Duplex units require very little additional floor space than a simplex unit requires. The two APCO pumps used in the system operate alternately to extend the life of both pumps . Both pumps operate simultaneously when service demands exceed the capabilities of a single pump. This AURORA product offers: Turbine design that handles vapor bubbles with no vapor lock. Design simplicity with a minimum of parts. Complete system package prepiped on a one-piece common base. Versatile, rugged, compact construction. Simplex and space-saving duplex Features Quality AURORA pumps pump test 3/16 thick steel flat head receiver with inlet, vent and drain connections Simplex pump with float switch Bronze fitted pump construction Removable channel rings Self-venting casings Piping from receiver to pumps Expansion type suction elbows Gauge glass assembly Factory assembled Coupling guardsOptional Features Duplex pumps with combination float switch and alternator Control panel prewired Electric alternator Thermometer Pressure gauges ASME receivers Electrolytic corrosion inhibitors Make-up feeder valve Inlet Y-strainer Special units 3/16 gauge galvanized steel receiver with inlet.

3 Vent and drain connectionsQuick Reference 210 Series Feature SelectorONE AND TWO STAGE CONDENSATE Operation and FeaturesStandard EquipmentSimplexReceiver with float switch, sight gauge glass with gauge cock, support, expansion elbow, piping, pump, motor, base, coupling and coupling guard. RECOMMENDED OPTIONS: pressure gauge, thermometer, magnetic starter and one hand-off-automatic switch mounted and wired Model 212 Receiver with a combination float switch alternator assembly, sight gauge glass with gauge cock, support, expansion elbows and piping, two pumps (one operational and one standby), motors, bases, coupling guards and couplings. RECOMMENDED OPTIONS: pressure gauges, thermometer, NEMA 1 control panel with two starters, two hand-off-automatic switches and two selector switches, mounted and wired EquipmentThermometerprovided with direct reading scale from 40 to 260 F.

4 Back angle 3 dialMake-Up Feeder Valve includes electric solenoid, reverse-action float switch and necessary # ASME Code Receiversof equal Pipe Tapssuch as vents in receiver as Anodeprovides electrolytic corrosion protection for the Alternatorconveniently mounted and wired on duplex Sealsfor single or two STAGE turbine Pumpssuch as Gaugeson pump Unitscompletely assembledSpecial Motorsvoltages and of OperationThe turbine pump derives its name from the many buckets machined into the periphery of the rotating impeller, which permits development of a relatively high pressure in an efficient and economic manner. More pressure is developed within the turbine pump than with a comparable size centrifugal pump. The pumped liquid is directed by the water passage so that it circulates in and out of the buckets many times on its way from the pump inlet to the pump outlet.

5 Additional energy is added to the liquid each time it passes through the buckets so the numerous passes generate a high discharge pressure. The pressure is developed without pulsations. While close clearances are used within the turbine pumps , there is no metal-to-metal contact. Volatile liquids are handled easily because a turbine pump readily handles vapor and air along with the liquid, thus eliminating the possibility of a vapor lock within the pump. Free-flowing and nonlubricating liquids are handled with a minimum of wear to pump parts because there is no metal-to-metal contact within the pump channel. The illustrations indicate the principle used in the handling of the liquid and developing of pressure in a regenerative turbine AND TWO STAGE CONDENSATE PUMPSPump Operation and FeaturesGauge Glass Guards Optional Galvanized Tank OptionalAurora APCO Turbine Pump Features Double suction minimizes axial thrust.

6 Replaceable channel rings and impellers. Opposed discharges to balance radial loads (two STAGE ). Interchangeable packing or mechanical seals. Seals are optionally available on single as well as two STAGE pumps . Large shaft for minimum deflections. Slingers protect bearings. O-rings prevent StartersMagnetic starters with overload and under-voltage protection are conveniently mounted on the unit. The starters are wired to the pump motors and to the float switch or combination float switch and alternator. Rated for three phase, 1/3 hp and larger; and single phase, 1 hp and larger. (Starters not required on single phase, hp motors or less.) On simplex units, the starter is mounted in a general purpose enclosure. On duplex units, magnetic starters are panel mounted in a NEMA 1 enclosure. Reset buttons are provided outside the starter enclosure for easy operation and AND TWO STAGE CONDENSATE PUMPSPump FeaturesA.

7 Steel Receiver is 3/16" thick to ensure long life. Receiver connections are threaded and include vent, inlet and Stainless Steel Float has adjustable travel to permit 1-1/2 times maximum return rate between stops. Combination float switch and alternator is standard on duplex Temperatures to 190 F water and selected for a minimum capacity of twice the rate of Brass Water Level Gauge glass assembly is furnished complete with shut-off Interchangeable Design provides future system expansion with receiver connections for up to two pumps . Just add a pump and pipe it Completely Assembled Piping from receiver to pump. Included are expansion type elbows to eliminate pipe Accessibility to pump and other components for easier maintenance. All pumps and piping are mounted beneath the receiver.

8 The unit bolts to a steel pumps designed for CONDENSATE applications will handle entrained vapor and air with liquid to eliminate vapor Glass Guards Optional Galvanized Tank Optional6 ONE AND TWO STAGE CONDENSATE PUMPSPump SelectionNotes:1. Unit number example: 15D4 designates 15 gallon receiver and D4 size pump. For selections not shown, please refer to Table selections are for intermittent operation if system requires continuous operating pumps , consult factory for pump Table 1750 ,0003,0004,0006,0008,00010,00015,00020,0 0025,00030,00035,00040,00050,00065,00010 0,000 Pump Capacity in Gallons151515153030306060606060100100200 Diameter (in.)141414141616162222222222242430 Length (in.)303030303838383838383838505066 Inlet (in.)22223333333333410 Unit15A3515C415D415E430F430G430H460I4A60 M460M460P460R4100M5100N5200J6hp1/31/31/3 1/31/31/31/23/4111-1/21-1/21-1/22315 Unit15A415C415D415E430F430G430H460I4A60M 460M460P460R4100M5100N5200J6hp1/31/31/31 /31/31/31/2111-1/21-1/21-1/223320 Unit15A415C415D415F430F430G430I460I4A60M 460P460P460L5100N5100P5200J6hp1/31/31/31 /31/31/23/411-1/21-1/21-1/2325530 Unit15C415C415E415F430G430H430I4A60P460R 460R460L560L5100N5100P5200J6 Thp1/31/31/31/21/23/41-1/22333557-1/2104 0 Unit15D415D415E415F430G430I430I4A60P460R 460R460L560L5100N5100P5200J6 Thp1/31/31/23/43/411-1/22333557-1/21050 Unit15D415E415F415G430I430I430P460R460K5 60K560L560N5100P5100P5200K6 Thp1/31/23/4111-1/22333557-1/27-1/21560 Unit15D415E415F415G430I430P430R460I560K5 60L560L560P5100P5100J6200K6 Thp1/23/4111-1/23335557-1/27-1/2101575 Unit15E415F415G415R430R430R430I4TA60K560 K560L560P560P5100J6100K6200K6

9 Thp3/4111-1/22233557-1/21010101585 Unit15F415G415E4T15G4T30G4T30I4T30I4TA60 K560L560L560H660H6100J6100K6hp1111-1/223 3557-1/27-1/2101015100 Unit15D4T15E4T15F4T15G4T3014T3014TA30I56 0K560L560G660J660K6100G6T100H6 Thp11-1/21-1/2233357-1/21010101015115 Unit15E4T15F4T15F4T15G4T30I4T30H530I560L 560L560F6T60F6T60G6T100H6T100J6 Thp1-1/21-1/2223357-1/27-1/21010151520 ReceiverPressure Pounds per Square InchBase SelectionUnit NumberhpBaseTypeSize15A35 to 15F41/3 to 3/41115F4 to 15R41 to 1-1/21230F4 to 30I41/3 to 3/41130I4 to 30I4A1 to 1-1/21230H5 to 30I53 to 51430G4T to 30I4T1 to 1-1/21230I4T31330I4TA21230I4TA31330P4213 30R41-1/2 to 21260I4A3/411 Base SelectionUnit NumberhpBaseTypeSize60I4A to 60R41 to 21260R431360I5 to 60L53 to 51460L5 to 60F6T7-1/2 to 101560G6T1516100M5 to 100N51-1/2 to 223100N5 to 100P53 to 524100P5 to 100J67-1/2 to 1025100K6 to 100J6T10 to 2026200J6 to 200K63 to 7-1/225200J6T to 200K6T10 to 15262004R to AND TWO STAGE CONDENSATE PUMPSD imensional DataNotes:1.

10 All dimensions in Not for construction purposes unless Duplex unit with mechanical alternator All connections are Conduit box and/or capacitor not shown as location and dimensions vary with each motor Flanges in accordance with American Write for Bulletin 110 for additional pump All simplex receivers have a blanked-off section opening available for possible future conversion to duplex *Always use max. "Y" dimensions BaseBase SizeABCDFGHT(1) 15,30 and 60 Gallon Receiver12624383522-5/852822725423923630 330284239236304343250472-5/846-1/2375444 264646123-3/87-1/24964846706724952(2) 100 and 200 Gallon Receiver12523444122-5/853422725484523636 330284845236364343254512-5/846-1/2415383 6565322-7/864464442646133-3/87-1/2497484 6706734952 Gal. (1)23/4304012-1/21414-1/2230(1)33/438501 3-5/81616-1/2260(1)33/4385019-5/82222-1/ 22100(2)31-1/4546621-5/82424-1/23200(2)4 1-1/4688226-7/83030-1/23 Pump SizeVWXY*A35-A4-C4-D4-E4 F4-G4-H4-I4-I4A4-3/41-1/4 I4T-I4TA6-1/161-1/4 250# 250# 250# FrameY*Mtr.