B SERIES ELECTRIC FURNACE - globalcommander.ca

INSTALLATION ANDUSERMANUALB SERIES ELECTRIC FURNACEMODELS: 21B10M, 21B15M, 21B18M, 21B20M, 21B25M, 83B13 AND83B24 IMPORTANT: READ AND SAVE THESE ; Sherbrooke, Quebec 1-800-567-27332019-09-20X40251 AWARNING Never tamper with the unit or its controls. User MUST contact aspecialized contractor when a failure occurs. DO NOT ATTEMPTto repair. When using a humidifier make sure not to damage the heatingelement bank. Poor maintenance of air filters OR an unbalanced static pressuremay result in a performance decrease. Always use genuine parts for maintenance or service call. Theuse of unbranded parts will void the warranty. The use of this unitwithout an air distribution duct will void the warranty. It is strictly forbidden to use jumpers to simulate heat demand. Risk of electrical shock. Disconnect power before installation,servicing, maintenance or field wiring.

b series electric furnace fb0004 installation and user manual important: read and save these instructions. models: 21b10m, 21b15m, 21b18m, 21b20m, 21b25m, 21b27ms, 83b13, 83b24 and 83b27 m a d e i n ca n a d a f a b r i q uÉ au c a n a d a nortron; sherbrooke, quebec www.dettson.ca 800 …

Tags:

  Series, Electric, Furnace, B series electric furnace

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of B SERIES ELECTRIC FURNACE - globalcommander.ca

1 INSTALLATION ANDUSERMANUALB SERIES ELECTRIC FURNACEMODELS: 21B10M, 21B15M, 21B18M, 21B20M, 21B25M, 83B13 AND83B24 IMPORTANT: READ AND SAVE THESE ; Sherbrooke, Quebec 1-800-567-27332019-09-20X40251 AWARNING Never tamper with the unit or its controls. User MUST contact aspecialized contractor when a failure occurs. DO NOT ATTEMPTto repair. When using a humidifier make sure not to damage the heatingelement bank. Poor maintenance of air filters OR an unbalanced static pressuremay result in a performance decrease. Always use genuine parts for maintenance or service call. Theuse of unbranded parts will void the warranty. The use of this unitwithout an air distribution duct will void the warranty. It is strictly forbidden to use jumpers to simulate heat demand. Risk of electrical shock. Disconnect power before installation,servicing, maintenance or field wiring.

2 Replace all panels beforeoperating. Failure to do so can result in electrical shock causingsevere injuries or death. When performing installation, servicing or cleaning the unit, it isrecommended to wear safety glasses and gloves. To assure a proper performance of your FURNACE , we recommendthat you use high quality name brand thermostats. When applicable local regulation comprises more restrictiveinstallation and/or certification requirements, the aforementionedrequirements prevail on those of this document and the installeragrees to conform to these at his own expense. For your safety, do not store or use gasoline or other flammableliquids and vapors in the vicinity of this unit or any other appliance. These instructions are intended to be used by qualified personnelwho have been trained in installing this type of of this FURNACE by an unqualified person may lead toequipment damage and/or hazardous condition which may leadto bodily harm.

3 This FURNACE is not watertight and is not designed for outdoorinstallation. This FURNACE shall be installed in such a manneras to protect its electrical components from leads to a hazardous electrical condition and topremature FURNACE failure, thus voiding the warranty. Do not block the combustion air openings in the FURNACE . Anyblockage will result in improper overheat situation and may resultin a fire hazard and/or cause bodily harm. The unit must have an uninterrupted or unbroken electricalground to minimize personal injury if an electrical fault performing electrical connection, the groundconductor must be firmly attached to the ground lug in thefurnace. Do not use this FURNACE as a construction ofthis FURNACE as a construction heater exposes the FURNACE toabnormal conditions, contaminated combustion air and the lackof air filters.

4 Failure to follow this warning can lead to prematurefurnace failure and/or vent failure which could result in a firehazard and/or bodily harm. The owner and/or the user is responsible of the following:Always maintain the immediate surrounding of the FURNACE freefrom combustible and highly flammables furnaceambient air should not have an excessive dust concentration andhumidity. Never operate this central heating appliance without anair filter. Before performing any service functions, unless operationsspecifically require the power to be on, make sure all utilities areturned OFF upstream of the appliance. Failure to comply withthis warning will cause a fire hazard and/or bodily harm. All questions regarding the operation, maintenance or warranty ofthis unit should be addressed to the company where this producthas been sold Never burn garbage or paper in the heating system and never leave rags or paper around the unit.

5 Return air grilles and warm air registers must not be : All local and national code requirements governing the electrical installation heating equipment, wiring andflue connections must be followed. Some of the codes that may be applicable are :ANSI/NFPA 70 NATIONAL ELECTRICAL CODECSA CANADIAN ELECTRICAL CODEOnly the latest issues of the above codes should be used, and are available from either:The National Fire Protection AgencyorThe Canadian Standards AssociationBatterymarch Park178 Rexdale , MA 02269 Rexdale, Ontario M9W 1R32 Table of Content1 Dimensions..32 General Requirements and Specifications..43 Operating Options..54 Breakers..55 Installation Notes.. Cold Air Return .. Electrica Wiring - Power Supply .. Connecting and Adjusting the Low Voltage Thermostat ..66 Use in Mobile Homes..77 Using Optional Equipment.. Two-Stage or Outdoor Thermostat.

6 Air Conditioning .. Electronic Air Cleaners and/or Powered FURNACE Humidifiers .. Interlock Conection ..88 Wiring Diagrams..99 Service Parts..1210 Maintenance..1311 Troubleshooting..1312 Warranty..141 Dimensions32 General Requirements and SpecificationsCAUTIONThis unit must be installed in a dry place, in a non-corrosive, well-ventilated environment, without excessive ambient temperatue must be over 10 C and under 27 C. If the ambient temperatue is 10 C or less, the plenummust be insulated on 10 ft linear minimum LOCATION The FURNACE should be centrally located to the heating POSITIONS It can be installed for vertical, horizontal or downflow operation. When installed horizontally, thefurnace should be positioned such as the door will not end up being on the top. The door should be on the side ofthe FURNACE , to ensure that the motor bearings are in their designed position.

7 In vertical downflow installations, useonly L - or T -shaped plenum with no openings or registers directly below INSTALLATION CLEARANCES As shipped from the factory, each unit is approved for zero inch clearance. Ifadditional clearance is required, it will be indicated on the data label attached to the TEMPERATURE RISE Furnaces are shipped to operate at (50 Pa) external static pressure. They arecertified for operation up to (125 Pa). Check below for temperature rise table on specification chart and,if necessary, adjust the unit to SERVICE CLEARANCE Units are serviced from the FRONT. Leave at least 24 (610 mm) clearance in front ofthe VOLTS - SINGLE PHASETEMPERATURE RISE@ " INCL. MOTORHP C FSPEED*21B10M1034121461/31832 LOW21B15M1551182671/32138 MED21B18M**1861419771/32546 MED21B20M**2068243861/32851 MED21B25M**25853041071/33564 MED208 VOLTS - ** PRESSUREFLOW(INCHES OF WATER COLUMN) :* FACTORY SETTINGS.

8 ** These models must NOT be setup to run continuously at LOW speed as it will cause overheating conditions. Thesemodels are certified to run only at HIGH and MED SUBJECT TO CHANGE WITHOUT NOTICE43 Operating OptionsThe FURNACE is shipped from the factory in a Standard Heating Mode (all switches are in the Down position). When the thermostatcalls for heat, the automatic controls will be activated and the FURNACE turned ON .The blower will run at low speed as the FURNACE heats up and will automatically switch to the pre-programmed heating speed whenadditional elements are activated by the time delay timing of this blower speed change will depend on the size of the FURNACE (10 kW and kW models do not change speed), andwhether COLDor MILDis selected on theSEASON may, however, change from the Standard Heating Mode by using the controls built into your Some homeowners prefer the blower to run at low speedto more evenly distribute air in the house.

9 In this position, theblower will run continuously on low and automatically change tothe necessary heating speed when heating elements are turnedon by the The blower motor will operate in the standard heatingmode, controlled by the During spring and fall, you may not require full heatingcapacity to maintain a comfortable temperature. In this position,approximately half of the elements are off-line and will not beenergized when the thermostat calls for All elements are on-line and controlled by : If outdoor or two-stage thermostat is used, switch MUSTbe in MILD position at all SERIES furnaces are equipped with breakers, located on thefront panel of the unit. These devices protect the heatingelements from overcurrent. If this situation occurs, the breakerswill open to cut the power from the heating elements : The number of breakers varies according to the furnacemodel; 21B10M model has no breakers, 21B15M, 21B18M,21B20M and 83B13 models have 2 breakers, and 21B25 Mand 83B24 models have 3 breakers.

10 Refer to Section 8 do not cut power to entire FURNACE , only to the heating elements. Do not use the breakers to turn off the FURNACE . Thepower to the whole unit can only be cut from the main electrical Air ReturnThe duct can be attached to either side, rear or the bottom of the side return there are four 1 (38 mm) knockouts which can be removed and used as an outline for cutting a 18 x 18 (457 mm x457 mm) return air opening in the FURNACE left or right side. Mount the filter frame to the FURNACE over the opening with the open sideof the frame facing front. Then attach the 19 x 19 (483 mm x 483 mm) air duct to the flanges on the filter bottom mounting, remove the screws holding the bottom plate to the FURNACE , discard the bottom plate and attach the filter frameto the bottom flanges with the open side of the frame facing Wiring - Power SupplyThe furnaces are completely factory wired.