Example: bankruptcy

B265-08022 Superior protection for arresters and …

Wildlife protection System Superior protection for arresters and wildlife Wildlife friendly Interference from In order to help minimize wildlife related outages, Eaton's Cooper The ground terminal wildlife guard, with a universal fit, wildlife is one of the Power Systems offers both line Reduce utility exposure to provides a higher level of wildlife terminal and ground terminal Endangered Species Act protection and better resistance leading causes of wildlife guards. Both guards are Less danger to wildlife to wind and other environmental perfect for traditional heavy-duty factors than other guards. service interruptions for and/or riser pole applications. Use these guards on all utilities worldwide. One Increase reliability and The line terminal wildlife guard can be quickly added to all Eaton's Cooper Power customer satisfaction issue, specific to medium voltage UltraSIL.

Title: B265-08022 Superior protection for arresters and wildlife Author: Eaton's Cooper Power Systems Subject: In order to help minimize wildlife related outages, Eaton's Cooper Power Systems offers both line terminal and ground terminal wildlife guards.

Tags:

  Protection, Superior, Arrester, B265 08022 superior protection for arresters and, B265, 08022

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of B265-08022 Superior protection for arresters and …

1 Wildlife protection System Superior protection for arresters and wildlife Wildlife friendly Interference from In order to help minimize wildlife related outages, Eaton's Cooper The ground terminal wildlife guard, with a universal fit, wildlife is one of the Power Systems offers both line Reduce utility exposure to provides a higher level of wildlife terminal and ground terminal Endangered Species Act protection and better resistance leading causes of wildlife guards. Both guards are Less danger to wildlife to wind and other environmental perfect for traditional heavy-duty factors than other guards. service interruptions for and/or riser pole applications. Use these guards on all utilities worldwide. One Increase reliability and The line terminal wildlife guard can be quickly added to all Eaton's Cooper Power customer satisfaction issue, specific to medium voltage UltraSIL.

2 Systems distribution arresters for optimum reliability and polymer-housed distribution- arrester applications, Reduce service interruption class surge arresters . The guard performance. occurs when animals on Reduce disruption to wildlife provides electrical insulation for the arrester in a compact, Increase your power quality a grounded surface . metrics inexpensive, and highly effective design that is engineered come in contact with Save time and money to provide optimal wildlife energized areas of the Reduce lineman's time in the protection . arrester . In many field identifying fault locations instances the result is a Protect your investment from wildlife damage costly power outage, a reduction in system reliability, and a wildlife tragedy. Reduce maintenance Weather resilient were tested to 22 kv versus the industry standard 5 kv.

3 In Line terminal wildlife guard enhanced design Both the line terminal and costs with Eaton's ground terminal wildlife guards addition, both passed design The line terminal wildlife guard contain Superior weather verification tests including the Cooper Power Systems resilient qualities including: following: extends slightly past the first shed, increasing distance to live wildlife protection Weather resistant Wet power frequency components while eliminating flashover the chances of foreign objects system. polyethylene construction Cold temperature test reaching energized areas. Proprietary ultraviolet inhibitor has been added to increase Ultraviolet aging Maintains flexibility resistance to tracking from UV Salt fog aging through extreme operating exposure temperatures, which allows Ground terminal wildlife for easy installation and Minimizes ice build-up in cold guard simple design removal during maintenance environments of overhead equipment Maintains flexibility down The ground terminal wildlife Integral molded flanges to -50 C guard covers the ground conform around leadwire terminal to protect against to eliminate access to high Superior performance* flashovers between live and voltage ground terminals.

4 Eaton's Cooper Power Systems Overlapping gates provide has tested our wildlife guards Can fit any standard arrester another barrier to protect the in accordance with IEEE Std Retrofittable in the field high voltage terminal of the 1656 -2010 standard. arrester Added in the field while Both the line terminal and Retrofits to existing Eaton's energized to avoid ground terminal wildlife guards Cooper Power Systems downtime arrester installations Can be installed with Accommodates a wide range hotstick of conductor sizes up to Discourages wildlife perching OD. Line terminal guard Part number: AV698X1C. Ground terminal guard The line terminal and ground Part number: AV731X1C. terminal wildlife protectors are shown here with the UltraSIL. polymer housed Evolution . surge arrester . Eaton 1000 Eaton Boulevard Cleveland, OH 44122.

5 United States Eaton, Cooper Power Systems, UltraSIL, and Eaton's Cooper Power Systems Business Evolution are valuable trademarks of Eaton in 2300 Badger Drive the and other countries. You are not per- Waukesha, WI 53188. United States mitted to use the Eaton Trademarks without the prior written consent of Eaton. For Eaton's Cooper Power Systems IEEE Std 1656 -2010 standard is a product information, trademark of the Institute of Electrical and 2014 Eaton Electronics Engineers, Inc., (IEEE). This call 1-877-277-4636 or All Rights Reserved Printed in USA. publication is not endorsed or approved by the IEEE. visit: Publication No. B235- 08022 All other trademarks are property June 2014 of their respective owners. *Individual design test reports are available upon request