Example: bankruptcy

Base Hinged Columns - Light Duty - Abacus Lighting

Column DimensionsXHY base HeightZ Root Length500mmOD2 ShaftDiameterCable Entry150mm x 50mmOD1 BaseDiameterGround LevelBASE Hinged COLUMNS4-8M base Hinged COLUMN Patent No: 968113 Light duty Designed to EN40. Hot dip galvanised to BS EN1461:1999. Manufactured in steel tube to EN10210 Flange PlateOptional Flush Door*400mm x 100mm AccessoriesXXSC003F Tamper resistant locking screwXXSC003F Key for locking screwELSAB1/6A Single fuse cut-out, 6A, loop in/out (not fi tted) ELSAB12/6A Twin fuse cut-out, 6A, loop in/out (not fi tted)* Flush Door OptionFlush door enables internal locking mechanism. Side fi tted locking screw not required on this model. Add /FD suffi Mounted ProductCodeHeightOD1OD2xyzWeight (kg)OTM (KNm)Shear (KN)Min. ConcreteDiameter*Counterbalance Type & Max. - Yellow 10kgRLS168 - White 20kgRLS168 - Red 29kgRLH168 - - Yellow 10kgRLS168 - White 18kgRLS168 - Red 27kgRLH168 - - White 10kgRLS168 - Red 18kgRLS168 - Blue 28kgRLH168 - - Blue 11kgRLS168 - Green 17kgRLH168 - 17kgDimensions (mm)*Root concrete diameter based on poor soil or better, min.

BASE HINGED COLUMNS TO OPERATE LIGHT DUTY BASE HINGED RANGE COUNTERBALANCE UNITS Spring Counterbalance - RLS168 The spring unit, type RLS168, is available in a range

Tags:

  Base, Duty, Light, Columns, Hinged, Base hinged columns light duty

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Base Hinged Columns - Light Duty - Abacus Lighting

1 Column DimensionsXHY base HeightZ Root Length500mmOD2 ShaftDiameterCable Entry150mm x 50mmOD1 BaseDiameterGround LevelBASE Hinged COLUMNS4-8M base Hinged COLUMN Patent No: 968113 Light duty Designed to EN40. Hot dip galvanised to BS EN1461:1999. Manufactured in steel tube to EN10210 Flange PlateOptional Flush Door*400mm x 100mm AccessoriesXXSC003F Tamper resistant locking screwXXSC003F Key for locking screwELSAB1/6A Single fuse cut-out, 6A, loop in/out (not fi tted) ELSAB12/6A Twin fuse cut-out, 6A, loop in/out (not fi tted)* Flush Door OptionFlush door enables internal locking mechanism. Side fi tted locking screw not required on this model. Add /FD suffi Mounted ProductCodeHeightOD1OD2xyzWeight (kg)OTM (KNm)Shear (KN)Min. ConcreteDiameter*Counterbalance Type & Max. - Yellow 10kgRLS168 - White 20kgRLS168 - Red 29kgRLH168 - - Yellow 10kgRLS168 - White 18kgRLS168 - Red 27kgRLH168 - - White 10kgRLS168 - Red 18kgRLS168 - Blue 28kgRLH168 - - Blue 11kgRLS168 - Green 17kgRLH168 - 17kgDimensions (mm)*Root concrete diameter based on poor soil or better, min.

2 230KN/m 290mm200mm15mm33mm x 25mm100mmType 0 FA000G Bolts/cross brace M16 x 500mm FC020 TemplateType 1 FA001G Bolts/cross brace M20 x 500mm FC021 Template8 100mm280mm200mm12mm30mm x 20mmHeightProjectionLengthOutreach BracketsSingle (S) Double (D) Spigot Lengths/SP 230mm/SP1 100mmFloodlight BracketsOverlap Fit on ShaftFlush Fit on SpigotType/BoltCentres (mm)Overlap Fit on ShaftFlush Fit on Spigot4mT041 RLST041 RLS/SP+/SP1*T041 RLST041 or /DPR1-03/S or /D*SingleFLI/1 or /DPR1-05/S or /D*Double (600)FLI/2 FLO/25mT051 RLST051 RLS/SP+/SP1*T051 RLST051 or /DPR1-03/S or /D*SingleFL1/1 or /DPR1-05/S or /D*Double (600)FL1/2 FLO/26mT061 RLST061 RLS/SP+/SP1*T061 RLST061 or /DPR1-03/S or /D*SingleFL1/1 or /DPR1-05/S or /D*Double (800)FL1/3 FLO/38mPost top lanterns onlyT081 RLST081 RLS/SPSingleFL2/1FL1/1 Double (800)Post top fl oodlight only*Outreach brackets series PR1 & PR2 below projection fi t onto 100mm spigot (/SP1).

3 + on standard 230mm spigot (/SP)For complete bracket information please refer to pages 35-37 Outreach & Floodlight Brackets Flange Plate Mounted ProductCodeHeightOD1OD2xyFlangePlateWeig ht (kg)OTM (KNm)Shear (KN)ConcreteDimension*Counterbalance Type & Max. WeightT041 RLS/FP4m1687628751050 Type x 800 RLS168 - Yellow 10kgRLS168 - White 20kgRLS168 - Red 29kgRLH168 - 29kgT051 RLS/FP5m1687638751050 Type x 800 RLS168 - Yellow 10kgRLS168 - White 18kgRLS168 - Red 27kgRLH168 - 27kgT061 RLS/FP6m1687648601050 Type x 800 RLS168 - White 10kgRLS168 - Red 18kgRLS168 - Blue 28kgRLH168 - 28kgT081 RLS/FP8m1688968301050 Type x 900 RLS168 - Blue 11kgRLS168 - Green 17kgRLH168 - 17kgHS*Concrete dimension based on a minimum ground bearing pressure of 15 OKN/m , (S = square dimension, H = depth)Dimensions (mm) Professional Lighting systems to suit any project.

4 Call 01623 518 333 9 Column Headload Capacity (m ) Based on UK rationalised wind loading factors for EN40 ProductCodeLantern Mounting/ProjectionMax. Headload (kg) Light 396 Medium 429 Heavy 466 Very Heavy 576T041 RLSPost Single Single Single Single Single Single s t Top170 .160 .13 30 .10 90 .0 Single For complete information on column headloads refer to Hinged COLUMNSTO OPERATE Light duty base Hinged RANGECOUNTERBALANCE UNITS Spring Counterbalance - RLS168 The spring unit, type RLS168, is available in a range of coloured springs. Each spring type has a given capacity, based on the column height and maximum safe working load. Column key is inserted into the end of the operating lever. Column key item Position = Lowered, Un-docked and Un-lockedFinish Floor LevelColumn Position = Raised, Docked and LockedFinish Floor LevelCounterbalanceProduct CodeColumn HeightSafe Working Load (kg)CounterbalanceWeights (kg)*RLS168-yellow4m, 5m17, 1022 RLS168-red4m, 5m, 6m27, 18, , 8m27, , 5m, 6m, 8m27, 27, 28, **Weight includes operating lever only when used with the Light duty base Hinged column range**Weight does not include operating lever ( for RLH168)Column Carrier - RL900 MFeaturesThe Abacus Column Carrier System has been designed to safely and conveniently move base Hinged Columns and guide them into position for installation with minimum effort.

5 Designed specifi cally for the root mounted spring raise and lowering column up to 168 and a minimum 6m mounting height Enables a column to be safely transported to its installation location and provides a stable platform for the column to be worked on, prior to erection The column carrier can be used by one man for moving Columns to the installation site The column can be lifted into place safely and easily by two men Note: See page 16 for further images of the product12 A1 Design height of the pivot above fi nished fl oor level is 300mm. If this distance is less than 230mm, diffi culty in fi tting counter balance will be experiencedA1 Hydraulic Counterbalance - RLH168 This hydraulic unit is popular with companies who have multiple column heights and headloads on one site or over a number of advantage is that it can operate the full column range regardless of height and Position = Lowered, Un-docked and Un-lockedFinish Floor LevelColumn Position = Raised, Docked and LockedFinish Floor LevelA2 Design height of the pivot above fi nished fl oor level is 300mm.

6 If this distance is less than 250mm, diffi culty in fi tting counter balance will be experiencedA2