Bathroom Ventilation Guide - TNB.COM

Bathroom Ventilation GuideProven, Reliable Bathroom Ventilation SolutionsGRAVITY SHUTTER GRILLES100mm white gravity shutter .. DCT0029125mm white gravity shutter .. DCT0044150mm white gravity shutter .. DCT0066 Also available in grey & FansThru Wall Fan KitsHeat/Fan/Light UnitsIn-Line Fan KitsExtract-A-Lite KitsWindow FansThru Roof Fan KitsPro SeriesClassicPro SeriesClassicPro SeriesPro SeriesClassicPro SeriesClassicClassicClassicRoom TypeRoom Size (m3)- Toilets- Laundries - No drier- Cellar- OfficesThese rooms require between 6 and 10 ACH(Air Changes per Hour)1-5m3 XFLP125XF125 XPLP125XP125 Heat n Vent 2 SFLP125SF125 ELLP125EL100WF150 HYPER6-10m3 XFLP125XF125 XPLP125XP125 Heat n Vent 2 SFLP125SF125 ELLP125EL125WF150 HYPER11-15m3 XFLP150XF150 XPLP150XP150 Heat n Vent 4 SFLP150SF150 ELLP150EL150WF150 HYPER- Bathrooms- Showers- EnsuitesThese rooms require between 11 and 15 ACH(Air Changes per Hour)1-10m3 XFLP150XF150 XPLP150XP150 Heat n Vent

Bathroom Ventilation Guide Proven, Reliable Bathroom Ventilation Solutions GRAVITY SHUTTER GRILLES 100mm white gravity shutter ..... DCT0029

Tags:

  Guide, Solutions, Ventilation, Bathroom, Ventilation solutions, Bathroom ventilation guide

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Bathroom Ventilation Guide - TNB.COM

1 Bathroom Ventilation GuideProven, Reliable Bathroom Ventilation SolutionsGRAVITY SHUTTER GRILLES100mm white gravity shutter .. DCT0029125mm white gravity shutter .. DCT0044150mm white gravity shutter .. DCT0066 Also available in grey & FansThru Wall Fan KitsHeat/Fan/Light UnitsIn-Line Fan KitsExtract-A-Lite KitsWindow FansThru Roof Fan KitsPro SeriesClassicPro SeriesClassicPro SeriesPro SeriesClassicPro SeriesClassicClassicClassicRoom TypeRoom Size (m3)- Toilets- Laundries - No drier- Cellar- OfficesThese rooms require between 6 and 10 ACH(Air Changes per Hour)1-5m3 XFLP125XF125 XPLP125XP125 Heat n Vent 2 SFLP125SF125 ELLP125EL100WF150 HYPER6-10m3 XFLP125XF125 XPLP125XP125 Heat n Vent 2 SFLP125SF125 ELLP125EL125WF150 HYPER11-15m3 XFLP150XF150 XPLP150XP150 Heat n Vent 4 SFLP150SF150 ELLP150EL150WF150 HYPER- Bathrooms- Showers- EnsuitesThese rooms require between 11 and 15 ACH(Air Changes per Hour)1-10m3 XFLP150XF150 XPLP150XP150 Heat n Vent 2 SFLP150SF150 ELLP125EL150WF150 HYPER11-15m3 XFLP150XF150 XPLP150XP150 Heat n Vent 4 SFLP150SF150 ELLP150EL150WF150 HYPER16-20m3 XFLP150(18)XF150(18)XPLP150(18)XP150(18) SFLP150/ MKLP125SF150 ELLP150EL150WF150(18)

2 ULTRA21-30m3 XFS230 XPS230 MKLP150WF230 ULTRA- Kitchens- Laundries - With drierThese rooms requirebetween 15 and 20 ACH (Air Changes per Hour)1-5m3 XFLP150XF150 XPLP150XP150 SFLP150SF150 ELLP125EL150WF150 HYPER6-10m3 XFLP150 XF150 XPLP150XP150 SFLP150/ MKLP125SF150 ELLP150EL150WF150 HYPER11-20m3 XFS230 XPS230 MKLP150WF230 ULTRACHOOSING THE RIGHT FANPLACEMENT OF YOUR Ventilation FAN2. Locate your Ventilation Fan- Wall/Ceiling- Thru Wall Kits- Heat/Fan/Light- In-Line Kits- Window- Thru Roof Kits- Low VoltageShowerLow VoltageWarm moist air is immediately attracted to cold surfaces, where it condenses into water droplets. Cold surfaces include glass, mirrors, tiles, wet-wall linings, cold uninsulated ceiling linings, etc.

3 You cannot remove all of this air at a rate fast enough to stop this happening & if you could, you would be standing in a wind tunnel. Using a Bathroom heater to warm the room prior to use greatly assists in reducing condensation by increasing the temperature of these cold To Prevent CondensationS - Standard models - are generally switched from a light - Timer models - this option incorporates a timer which will run on for up to 20 minutes after you switch off the - Pull-Cord models - Pull-cord mechanism switches the fanA - Automatic Shutter models - When powered the fan starts immediately & the shutters open slowly after approx 20 SWITCHING OPTIONSBALL BEARING MOTORSBall Bearing motors are the highest quality bearing option available for

4 Fans. As part of our commitment to product development and improvement all Manrose fans have been upgraded to include ball bearing motors. With fan reliability a critical factor in fan performance, our quality ball bearing motors will ensure Manrose fans perform consistently over a number of years. As a result of this we are proud to support all Manrose fans with a 5 year warranty. All Manrose fans comply to AS/NZS :1998 AZ5 Year Warranty Follow the selected Room Size row across & select one of the fan kits available based on your mounting requirements (see top headings and photos)Eg: If you require a Thru Wall Kit then you can choose either the XP150 or XPLP150 : To calculate the Fan Performance Multiply the room volume (eg: ) by the maximum recommended air changes (eg: Bathroom = 15).

5 Eg: x 15 = XP150 with a performance of 313m3/hr achieves this your required applicationEg: Bathrooms(11 - 15 air changes per hour) Air Changes per Hour means an airflow rate sufficient to remove/replace the total volume of air in a given room at a specified number of times each hour1 Calculate the volume of the room in cubic metres (m3) by multiplying the length x width x : x x = LHW2(Select a room volume range of 16-20m3)Note: All selections are based on installed fan performance and maximum air change rates (figures in brackets show actual air changes stated if less than maximum).ApplicationWall/Ceiling FansThru Wall Fan KitsHeat/Fan/Light UnitsIn-Line Fan KitsExtract-A-Lite KitsWindow FansThru Roof Fan KitsPro SeriesClassicPro SeriesClassicPro SeriesPro SeriesClassicPro SeriesClassicClassicClassicRoom TypeRoom Size (m3)- Toilets- Laundries - No drier- Cellar- OfficesThese rooms require between 6 and 10 ACH(Air Changes per Hour)

6 1-5m3 XFLP125XF125 XPLP125XP125 Heat n Vent 2 SFLP125SF125 ELLP125EL100WF150 HYPER6-10m3 XFLP125XF125 XPLP125XP125 Heat n Vent 2 SFLP125SF125 ELLP125EL125WF150 HYPER11-15m3 XFLP150XF150 XPLP150XP150 Heat n Vent 4 SFLP150SF150 ELLP150EL150WF150 HYPER- Bathrooms- Showers- EnsuitesThese rooms require between 11 and 15 ACH(Air Changes per Hour)1-10m3 XFLP150XF150 XPLP150XP150 Heat n Vent 2 SFLP150SF150 ELLP125EL150WF150 HYPER11-15m3 XFLP150XF150 XPLP150XP150 Heat n Vent 4 SFLP150SF150 ELLP150EL150WF150 HYPER16-20m3 XFLP150(18)XF150(18)XPLP150(18)XP150(18) SFLP150/ MKLP125SF150 ELLP150EL150WF150(18)ULTRA21-30m3 XFS230 XPS230 MKLP150WF230 ULTRA- Kitchens- Laundries - With drierThese rooms requirebetween 15 and 20 ACH (Air Changes per Hour)1-5m3 XFLP150XF150 XPLP150XP150 SFLP150SF150 ELLP125EL150WF150 HYPER6-10m3 XFLP150 XF150 XPLP150XP150 SFLP150/ MKLP125SF150 ELLP150EL150WF150 HYPER11-20m3 XFS230 XPS230 MKLP150WF230 ULTRAFAN SELECTION GUIDE4.

7 Wet Areas & Recommended Fan TypesWhen considering where in the room to place an extractor fan, you must consider the wet areas. For example a fan mounted directly over a bath or shower must be a low voltage fan if less than off the location of an extraction fan will ensure maximum air-flow through the room. Air extracted from a Bathroom should be replaced with dry air drawn from an adjacent room or hallway. Make up air is the amount of air that needs to enter the Bathroom in order for the fan to work Consider your Location Options within the RoomPOOR CIRCULATIONMEDIUM CIRCULATIONNote: A door vent may be used to supplement make-up airflow Order Code: FAN0159 BEST CIRCULATIONZone 1: Requires a Low Voltage Fan Zone 2: Any fan model can be usedZone 3: Any fan model can be usedNote: All selections are based on installed fan performance and maximum air change rates (figures in brackets show actual air changes stated if less than maximum).

8 FAN SPECIFICATIONSPro Series products have been designed to meet the requirements of the professional market with higher specifications and performance of the product. These products are denoted in red text OR WALL MOUNTED FANSXFLP150 CIRCULAR FASCIA OPTIONDuct SizeModel MethodFan TypePerformance*Order CodePRO SERIES150mmXFLP150SS**StandardAxial87l/s , 313m3/hrFAN0594150mmXFLP150ST**TimerAxia l87l/s, 313m3/hrFAN0595125mmXFLP125SS**StandardA xial36l/s, 130m3/hrFAN0589125mmXFLP125ST**TimerAxia l36l/s, 130m3/hrFAN0590 CLASSIC150mmXF150 SStandard Axial87l/s, 313m3/hrFAN0120150mmXF150 TTimer Axial87l/s, 313m3/hrFAN0127150mmXF150 AStandard (Auto Shutter)

9 Axial87l/s, 313m3/hrFAN0121125mmXF125 SStandardAxial36l/s, 130m3/hrFAN0072125mmXF125 TTimerAxial36l/s, 130m3hrFAN0075100mmXF100S StandardAxial23l/s, 85m3/hrFAN0046 Options available: Timer Pull-cord PIR Automatic Shutter Low VoltageXF125XF150 Please Note: 1. If the Pro Series fans are mounted in the wall, you will need a minimum 110mm wall Low Voltage models available for installation in damp areas.* All Fan performance figures listed above are in free air.** Circular fascia low profile option available, please request at point of UNITS HEAT n VENT 2 Duct SizeModel TypePerformance (Free air)Performance (*Installed)Order CodePRO SERIES125mmPro Series Heat n Vent 4 Centrifugal67l/s, 240m3/hr60l/s, 216m3/hrFAN0995125mmPro Series Heat n Vent 2 Centrifugal63l/s, 226m3/hr50l/s, 180m3/hrFAN0940 CLASSIC100mmHeat n Vent 2 Centrifugal54l/s, 194m3/hr35l/s, 126m3/hrFAN2162100mmLight n Vent 1 Centrifugal74l/s, 2653/hr51l/s, 184m3/hrFAN0539100mm2 Heat n LightN/AN/AN/AFAN2200 HEAT n VENT 4 Please Note: 1.

10 *Installed fan performance results tested with typical installation using 3m of duct, one bend and an exterior All Heat/Fan/Light kits include 3 metres of duct, an exterior grille & switch available: Satin Silver fasciaTHRU WALL FAN KITS Please Note: 1. If the Pro Series fans are mounted in the wall, you will need a minimum 110mm wall If you require the circular low profile model please request a circular fascia at point of Low Voltage Thru Wall Fans models available for installation in damp Comes complete with semi-rigid duct and gravity grille. Note: All fan performance figures listed above are in free SizeModel MethodFan TypePerformance*Order CodePRO SERIES150mmXPLP150 SSStandardAxial87l/s, 313m3/hrFAN0621150mmXPLP150 STTimerAxial87l/s, 313m3/hrFAN0623125mmXPLP125 SSStandardAxial36l/s, 130m3/hrFAN0614125mmXPLP125 STTimerAxial36l/s, 130m3/hrFAN0615 CLASSIC150mmXP150 SStandardAxial87l/s, 313m3/hrFAN0135150mmXP150 TTimerAxial87l/s, 313m3/hrFAN0141150mmXP150 AStandard (Auto Shutter)Axial87l/s, 313m3/hrFAN0136125mmXP125 SStandardAxial36l/s, 130m3/hrFAN0080125mmXP125 TTimerAxial36l/s, 130m3/hrFAN0083100mmXP100S StandardAxial23l/s, 85m3/hrFAN0053 Options available.