Transcription of BD35F Direct Current Compressor - Nova Kool
1 April Sheet (Replaces )BD35 FDirect Current CompressorR134a12 - 24 VBA20117070 9B2B1123594616127 IN GERMANYB arcode onwhite backgroundGrey backgroundBlue stripeApplicationR134aN 1297S= Static cooling normally sufficientO= Oil coolingF1= Fan cooling m/s( Compressor compartment temperatureequal to ambient temperature)F2= Fan cooling m/s necessary8415EC approval mark(electronic unit)e40277 0024V cut-in[V] cut-out[V] cut-in[V] cut-out[V] (R2)[k ] cut - in [V] (HBP)Evaporating temperature range C-30 to 0 (10)Voltage range / max. voltage12 - 24V DC / DCMax. machine compartment temperature C55 Comp. cooling at ambient CS or F1* BD35F without electronic unit101Z0200 Electronic unit 12-24V DC - standardsingle: 101N0210, 30 pcs: 101N0211 Electronic unit 12-24V DC - w. metal shieldingsingle: 101N0220, 30 pcs: 101N0221 Electronic unit 12-24V DC - with AEOsingle: 101N0300, 30 pcs: quantitycm3150 Maximum refrigerant charge g300 Free gas vol.
2 In compressorcm3870 Weight: Compressor /Electronic numbersApplicationDesignDimensionsHeight mm A137B135B1128B273 Suction mm mm mm + + on a battery protection settings12V cut-out [V] cut-out [V] cut-in [V] battery protection settings (no connection C - P)* depending on applicationMotor typeVariable speedResistance, all 3 windings (25 C) 72/245 95/54 0277 00, UL984, DCTHERMALLYPROTECTEDSYSTEMA pproval 2004+-+-+FDCPT-+8236-2 Terminal plugPower supplyFuseMain switchLEDFanThermostatR1R2 Power consumption wattCurrent consumption (for 24V applications the following must be halved) ACOP (EN 12900/CECOMAF) W/WCapacity (ASHRAE) wattCapacity (EN 12900/CECOMAF) wattCOP (ASHRAE) W/WC \ , , , , \ , , , , \ , , , , \ , , , , \ , , , , \ , , , , conditionsEN 12900/CECOMAFASHRAEC ondensing temperature55 C55 CAmbient and suction gas C32 CLiquid temperature55 C32 CStatic cooling, 12V DC1 Watt = kcal/hMotorspeedrpm2,0002,5003,0003,500 AEO2,0002,5003,0003,500 Resistor(R1) speedElectronicunit101N0210101N0220101N0 300with AEOO perational errors shown by LED (optional)
3 Numberof flashesError typeThermal cut-out of electronic unit(If the refrigeration system has been too hea-vily loaded, or if the ambient temperature ishigh, the electronic unit will run too hot).5 Minimum motor speed error(If the refrigeration system is too heavily lo-aded, the motor cannot maintain minimumspeed at approximately 1,850 rpm).4 Motor start error3(The rotor is blocked or the differential pres-sure in the refrigeration system is too high(>5 bar)).Fan over- Current cut-out2(The fan loads the electronic unit with morethan 1 Apeak).1 Battery protection cut-out(The voltage is outside the cut-out setting).In AEO (Adaptive Energy Optimizing) speedmode the BD Compressor will always adaptits speed to the actual cooling automobile fuseNotDIN 725812V: 15 Adeliverable24V: DanfossMounting accessoriesBolt joint for one compressor118-1917 Bolt joint in quantities118-1918 Snap on in quantities118-1919 AccessoriesDevicesWire dimensions*Length between battery and electronic unitMax length*24V length*12V