BETA STAR LIFE SCIENCE EQUIPMENT

MEDIUM STERILIZER SERIES 24 x 36 and 26 x 36 BETA STAR LIFE SCIENCE EQUIPMENTBETA STAR LIFE SCIENCE EQUIPMENTECO-FRIENDLYR educe your facility s water footprint with Beta Star s EnviroVac Vacuum System. Mechanical and programmable conservation features are integrated into a variety of cycles for the Beta Star LSII Series SOURCE MANUFACTURINGBeta Star s raw plate to FAT promise ensures greater control over project delivery while ensuring US Made and technicians are protected through temperature and pressure monitoring, relief valves, safety interlocks, and automatic COST OF OWNERSHIPNon-proprietary components and cost-effective service rates create a lower cost of ownership than competitors who charge unsustainable amounts for high wear STAR LIFE SCIENCE EQUIPMENTBETA STAR LIFE SCIENCE EQUIPMENT 584 POPLAR ROAD HONEY BROOK.

medium sterilizer series beta star life science equipment beta star life science equipment • betastar.com • 584 poplar road • honey brook, pa 19344 • 610.273.4222 page 2

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of BETA STAR LIFE SCIENCE EQUIPMENT

1 MEDIUM STERILIZER SERIES 24 x 36 and 26 x 36 BETA STAR LIFE SCIENCE EQUIPMENTBETA STAR LIFE SCIENCE EQUIPMENTECO-FRIENDLYR educe your facility s water footprint with Beta Star s EnviroVac Vacuum System. Mechanical and programmable conservation features are integrated into a variety of cycles for the Beta Star LSII Series SOURCE MANUFACTURINGBeta Star s raw plate to FAT promise ensures greater control over project delivery while ensuring US Made and technicians are protected through temperature and pressure monitoring, relief valves, safety interlocks, and automatic COST OF OWNERSHIPNon-proprietary components and cost-effective service rates create a lower cost of ownership than competitors who charge unsustainable amounts for high wear STAR LIFE SCIENCE EQUIPMENTBETA STAR LIFE SCIENCE EQUIPMENT 584 POPLAR ROAD HONEY BROOK.

2 PA 19344 1 Door Quantity Single Double Door Operation Manual Automatic Installation Type Free Standing Recessed One Wall Recessed Two Wall Cabinet Enclosure None Full Cabinet (Right & Left) Right Side Left Side Chamber Process Non-Effluent Effluent (BSL-3) Chamber Piping Copper and brass piping with threaded NPT fittings Stainless steel piping with Ferrule type fittings Stainless steel piping with Sanitary fittings Vacuum System Water Ejector EnviroVac Water Conservation Liquid Ring Jacket Steam Source House Steam Same as ChamberChamber Steam Source House Steam Electric Steam Generator (carbon steel) Electric Steam Generator (stainless steel) Steam to Steam Generator Compressed Air Source None required Stand alone air compressor House compressed air Beta Connect System Remote Support Mobile Observation and Control Central Sterilization Management Predictive Maintenance and AnalysisGET STARTED CREATING YOUR STERILIZER**FOR A FULL LIST OF OPTIONS, PLEASE CONTACT STERILIZER SERIESBETA STAR LIFE SCIENCE EQUIPMENTBETA STAR LIFE SCIENCE EQUIPMENT 584 POPLAR ROAD HONEY BROOK.

3 PA 19344 224 x 36 DRAWINGSFOR ALL DIGITAL DRAWINGSCONTACT US AT SERIES STANDARD SIZESC hamber DimensionsChamber Dimensions24 x 36 Series26 x 36 SeriesWidthHeightDepthWidthHeightDepth24 "36"36"26 36"36"24"36"48"26 36"48"24"36"60"26 36"60"24"36"72"26 36"72"24"36"84"26 36"84"BETA STAR LIFE SCIENCE EQUIPMENTBETA STAR LIFE SCIENCE EQUIPMENT 584 POPLAR ROAD HONEY BROOK, PA 19344 3 MEDIUM STERILIZER SERIESBETA STAR LIFE SCIENCE EQUIPMENTBETA STAR LIFE SCIENCE EQUIPMENT 584 POPLAR ROAD HONEY BROOK, PA 19344 4 PLUMBING UTILITY REQUIREMENTSC hamber Size243636243648243660243672243684 DrainConnection Size3 4 Standard MaterialBy Others, Suitable for 140OF/60 OCPressureAtmosphere (Gravity Drain)House SteamConnection Size1 1 1/4 Standard Material2 Black Iron/Brass or StainlessPeak Flow Rate180 lb/hr215 lb/hr260 lb/hr295 lb/hr320 lb/hrAverage Flow Rate120 lb/hr145 lb/hr178 lb/hr200 lb/hr215 lb/hrPressure50-80 PSIG50-80 PSIG50-80 PSIG50-80 PSIG50-80 PSIGW ater Requirements for Water Ejector Vacuum Equipped Machine (Standard)Connection Size1''N/A3 Standard Material2 CopperN/A3 Peak Flow Rate14 gal/minN/A3 Average Flow Rate8 gal/minN/A3 Pressure30-50 PSIGN/A3 Water Requirements for EnviroVac Equipped Machine (Optional)

4 Connection Size1/2 3/4 Standard Material2 CopperPeak Flow Rate3 gal/min7 gal/minAverage Flow Rate2 gal/min4 gal/minPressure40-60 PSIGI nstrument Air Pneumatic Valve Equipped Machine (Standard)Connection Size1/2"Standard Material2 CopperPeak Flow Rate2 SCFMA verage Flow Rate1 SCFMP ressure80-100 PSIG24 x 36 UTILITY REQUIREMENTSKey1 Recommended utility values indicate design standard for efficient machine operation. Consult with the Beta Star Sales Staff for site specific utility values which may fall outside of indicated (s) may vary to suit Ejector not available on 243672 and 243684 modelsMEDIUM STERILIZER SERIESBETA STAR LIFE SCIENCE EQUIPMENTBETA STAR LIFE SCIENCE EQUIPMENT 584 POPLAR ROAD HONEY BROOK, PA 19344 5 ELECTRICAL UTILITY REQUIREMENTSC hamber Size243636243648243660243672243684 Sterilizer Controls (Optional Electrical Steam Generator Controls)Voltage120V (120V)Phase1 (1)Frequency60 Hz (60 Hz)Amp Draw3A (5A)TypeDedicated Circuit (handles both control systems)EnviroVac (Optional)4 Voltage208V/480 VPhase3 Frequency60 HzAmp Steam Generator (Optional)

5 4 Voltage208 VPhase3 Frequency60 HzAmp Draw134A167A167A200A299 ATypeDisconnectElectric Steam Generator (Optional)4 Voltage480 VPhase3 Frequency60 HzAmp Draw59A73A73A87A129 ATypeDisconnectAir Compressor (Optional)5 Voltage120 VPhase1 Frequency60 HzAmp Draw12 ATypeDuplex OutletEthernet Connection Required for Optional Beta Connect Remote Connectivity SystemKey4 Operating voltage must be compressor only required for pneumatic valve machine installations which have no house instrument air STERILIZER SERIESBETA STAR LIFE SCIENCE EQUIPMENTBETA STAR LIFE SCIENCE EQUIPMENT 584 POPLAR ROAD HONEY BROOK, PA 19344 6 MEDIUM STERILIZER SERIES26 x 36 UTILITY REQUIREMENTSPLUMBING UTILITY REQUIREMENTS1 Chamber Size263636263648263660263672263684 DrainConnection Size3 4 Standard MaterialBy Others, Suitable for 140OF/60 OCPressureAtmosphere (Gravity Drain)

6 House SteamConnection Size1 1 1/4 Standard Material2 Black Iron/Brass or StainlessPeak Flow Rate170 lb/hr204 lb/hr236 lb/hr272 lb/hr306 lb/hrAverage Flow Rate99 lb/hr121 lb/hr142 lb/hr165 lb/hr187 lb/hrPressure50-80 PSIGW ater Requirements for Water Ejector Vacuum Equipped Machine (Standard)Connection Size1''N/A3 Standard Material2 CopperN/A3 Peak Flow Rate14 gal/minN/A3 Average Flow Rate8 gal/minN/A3 Pressure30-50 PSIGN/A3 Water Requirements for EnviroVac Equipped Machine (Optional)Connection Size1/2 3/4 Standard Material2 CopperPeak Flow Rate3 gal/min7 gal/minAverage Flow Rate2 gal/min4 gal/minPressure40-60 PSIGI nstrument Air Pneumatic Valve Equipped Machine (Standard)Connection Size1/2"Standard Material2 CopperPeak Flow Rate2 SCFMA verage Flow Rate1 SCFMP ressure80-100 PSIGKey1 Recommended utility values indicate design standard for efficient machine operation.

7 Consult with the Beta Star Sales Staff for site specific utility values which may fall outside of indicated (s) may vary to suit Ejector not available on 263672 and 263684 modelsBETA STAR LIFE SCIENCE EQUIPMENTBETA STAR LIFE SCIENCE EQUIPMENT 584 POPLAR ROAD HONEY BROOK, PA 19344 7 MEDIUM STERILIZER SERIESELECTRICAL UTILITY REQUIREMENTSC hamber Size263636263648263660263672263684 Sterilizer Controls (Optional Electrical Steam Generator Controls)Voltage120V (120V)Phase1 (1)Frequency60 Hz (60 Hz)Amp Draw3A (5A)TypeDedicated Circuit (handles both control systems)EnviroVac (Optional)4 Voltage208V/480 VPhase3 Frequency60 HzAmp Steam Generator (Optional)4 Voltage208 VPhase3 Frequency60 HzAmp Draw134A167A200A200A300 ATypeDisconnectElectric Steam Generator (Optional)4 Voltage480 VPhase3 Frequency60 HzAmp Draw59A73A87A87A130 ATypeDisconnectAir Compressor (Optional)

8 5 Voltage120 VPhase1 Frequency60 HzAmp Draw12 ATypeDuplex OutletEthernet Connection Required for Optional Beta Connect Remote Connectivity SystemKey4 Operating voltage must be compressor only required for pneumatic valve machine installations which have no house instrument air STAR LIFE SCIENCE EQUIPMENTBETA STAR LIFE SCIENCE EQUIPMENT 584 POPLAR ROAD HONEY BROOK, PA 19344 8 STANDARD FEATURESMEDIUM STERILIZER SERIESSPEC REVIEW CONSULTATIONOur team has decades of experience in the sterilization industry to review your specifications and answer specific product questions. We would like to assist you with your plans and requirements for your next facility construction or renovation.

9 Contact a member of our team to get your consultation Star s extensive service experience, complete in-house manufacturing and dedicated engineering and manufacturing personnel provide industry leading safety, reliability and lowest cost of ownership. All Beta-Star sterilizers include free draining vessels to ensure the driest possible process. Baffled steam injection eliminates load steam impingement while providing even temperature distribution. Modular frames provide secure support, service access and adjustability to suit the most challenging installations. VESSEL CONSTRUCTIONAll Beta Star vessels are manufactured at our corporate headquarters in Honey Brook, PA.

10 The engineered chamber, door, and vessel jacket in manufactured in accordance with the standards defined by the American Society of Mechanical Engineers (ASME), Unified Pressure Vessel Code, Section VIII, Division 1. The fabricated chamber and door maintain operating pressures and temperatures from full vacuum to 45 psig at 300OF. A few of the vessel features include: Vessel finish polished to 25 Ra. Optional mechanical finish surface to 10 Ra is available. Jacket constructed of 304L or optionally specified 316L type stainless PROCESS OVERVIEW Chamber floor geometry shall facilitate free flow gravity drain. Chamber floor will be furnished with appropriate number of chamber drains, each with their own drain strainer to prevent clogging.