BG2 range manual call point - Cooper MEDC

CROUSE-HINDSSERIESMEDC signalling and alarmsBG2 rangemanual call pointOverview This manual fire alarm call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where lightweight combined with a high level of corrosion resistance is Zone 0, Zone 1 and Zone 2 use Ex de, Ex ia or weatherproof ATEX approved - Ex II 1GD (Ex ia) - Ex II 2GD (Ex de) IP66 and IP67 Certified temperature from -40 C to +70 C* Corrosion resistant red painted GRP Retained stainless steel cover screws Optional lift flap Key operated test facility Lightweight and robust *Model dependentAll specifications, dimensions, weights and tolerances are nominal (typical) and Eaton reserve the right to vary all da

CROUE-HINDS MEDC signalling and alarms SERIES BG2 range manual call point Overview This manual fire alarm call point has been designed for use in flammable atmospheres and harsh

Tags:

  Manual, Call, Ranges, Points, Bg2 range manual call point

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of BG2 range manual call point - Cooper MEDC

1 CROUSE-HINDSSERIESMEDC signalling and alarmsBG2 rangemanual call pointOverview This manual fire alarm call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where lightweight combined with a high level of corrosion resistance is Zone 0, Zone 1 and Zone 2 use Ex de, Ex ia or weatherproof ATEX approved - Ex II 1GD (Ex ia) - Ex II 2GD (Ex de) IP66 and IP67 Certified temperature from -40 C to +70 C* Corrosion resistant red painted GRP Retained stainless steel cover screws Optional lift flap Key operated test facility Lightweight and robust *Model dependentAll specifications, dimensions, weights and tolerances are nominal (typical) and Eaton reserve the right to vary all data without prior liability is accepted for any consequence of B, Sutton ParkwayOddicroft LaneSutton in AshfieldUnited KingdomNG17 5 FBT.

2 +44 (0) 1623 444 2017 EatonAll Rights ReservedPrinted in UKPublication November 2017 Eaton is a registered other trademarks are property of their respective check here for latest version of the datasheetEx de, Ex ia, weatherproofDSMC0006/A 11/17 CertificationsATEX Ex deCert. no. BAS02 ATEX2105X. ATEX Approved Ex II 2 GDCertified to: EN60079-0, EN60079-1, EN60079-7, EN60079-31Ex d e IIC T6 Gb, Ex tb IIIC T85 C Db (switch only)Ex d e mb IIC T4 Gb, Ex tb IIIC T135 C Db (with resistors & diodes)ATEX Ex iaCert no. Baseefa 03 ATEX0084X. ATEX Approved Ex II 1 GDCertified to: EN60079-0, EN60079-11Ex ia IIC T4 Ga, Ex ia IIIC T135 C DaSpecificationsMaterialAnti static UV resistant glass reinforced polyesterFinishPainted redCertified temp-40 C to +70 CVoltageUp to 250 Vac.

3 Up to 50 Vdc (model dependent) protectionIP66 and IP67 Cable entries2 x M20 bottomTerminals6 x mm Resistors valuesEx de - 100 minimum, 39 K maximumEx ia - 470 minimumSwitch ratings Switch only 30 Vdc 5A (resistive) or 3A (inductive) 30-50 Vdc 1A (resistive or inductive) 250 Vac 5A (resistive or inductive) Resistor(s) 24 Vdc ModelOptionsGeneral arrangement drawing (all dimensions in mm)FlapFinish*Specify resistor valuesModel BG2W - ac or dc BG2I - Up to 28V ( ) BG2E - dc BG2E - acCodeBG2 WNNBG2 INNBG2 EDCBG2 EACO ptions Switch only End of line resistor In line resistor In line and end of line resistor Diode (specify location & value)Code 1 2* 3* 4* 5 FlapFittedNot fittedCode F*NFinishRed paintedCodeRThe Eaton BG range of manual alarm call point caters for numerous options such as variety of colours, LED indication, earth continuity, double switch, etc.

4 See separate catalogue sheet for details*Polycarbonate lift flapOrder ing requirements The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate boxALL CIRCUITS SHOWN WITH GLASS INTACT