Example: marketing

Biosafety Cabinet, Model LA2-4A -E. Class II, Type …

Labculture Class II, Type A2 Biosafety Cabinet, Model II, Type A2 and B2 Biological Safety CabinetsThe Most Certified Energy-Efficient, Safe, and Ergonomic Biosafety Cabinet in the WorldNSF 49, UL 61010, JIS K3800, CFDA YY-0569, EN 124692LA2 & LR2 Class II Type A2 / LB2 Class II Type B2 Biological Safety CabinetsLabculture l Labculture Available in , , , and meter models(3', 4', 5', 6' and 8'). Shown with optional telescoping all safety information on one screenCentered and angled down for easy reach & viewingSelectable Quickstart mode for fast operationSentinelTM Gold Microprocessor ControllerSingle Piece WallSingle Piece Work TrayRaised Arm RestAngled Drain PanRS 232 Port to send operational information to Building Management System (BMS)Zero Volt Relay Contact to turn ON/OFF exhaust blower and signal the building alarmRS 232 Port and Zero Volt Relay ContactLABCULTURE Class II TYPE A2 (LA2) and B2 (LB2) Biosafety cabinets , FEATURING ADVANCED MICROPROCESSOR CONTROLLEREsco LA2 Exhaust: OKI: m/sSocket: ON 15:34 Sash: OK D.

Labculture ® Class II, Type A2 Biosafety Cabinet, Model LA2-4A_-E. Class II, Type A2 and B2 Biological Safety Cabinets The Most Certi ed Energy-Ef …

Tags:

  Model, Types, Biosafety, Cabinets, Class, S silica, Biosafety cabinet, Model la2 4a e

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Biosafety Cabinet, Model LA2-4A -E. Class II, Type …

1 Labculture Class II, Type A2 Biosafety Cabinet, Model II, Type A2 and B2 Biological Safety CabinetsThe Most Certified Energy-Efficient, Safe, and Ergonomic Biosafety Cabinet in the WorldNSF 49, UL 61010, JIS K3800, CFDA YY-0569, EN 124692LA2 & LR2 Class II Type A2 / LB2 Class II Type B2 Biological Safety CabinetsLabculture l Labculture Available in , , , and meter models(3', 4', 5', 6' and 8'). Shown with optional telescoping all safety information on one screenCentered and angled down for easy reach & viewingSelectable Quickstart mode for fast operationSentinelTM Gold Microprocessor ControllerSingle Piece WallSingle Piece Work TrayRaised Arm RestAngled Drain PanRS 232 Port to send operational information to Building Management System (BMS)Zero Volt Relay Contact to turn ON/OFF exhaust blower and signal the building alarmRS 232 Port and Zero Volt Relay ContactLABCULTURE Class II TYPE A2 (LA2) and B2 (LB2) Biosafety cabinets , FEATURING ADVANCED MICROPROCESSOR CONTROLLEREsco LA2 Exhaust: OKI: m/sSocket: ON 15:34 Sash: OK D.

2 M/sMonitors real-time airflow for safetyAlert the user if airflow is insufficientAirflow SensorLarge radius for easy cleaningSide-mounted electrical outlets and staggered service fixtures, for easy reachRecessed to contain spillageCurved grill to prevent blockageHelps prevent grille blockingComfortable working posture Easy to clean Does not harbor contaminants2 Esco Labculture Class II Type A2 (LA2) has passed more performance tests in more languages, for more certifications throughout more countries than any other biological safety cabinet in the 49UL 61010,JIS K3800 CFDA YY-0569EN 124693 The Most Certified BSC in the WorldStandards ComplianceBiosafety CabinetsAir QualityFiltrationElectrical SafetyNSF / ANSI 49, USA* EN 12469, Europe** JIS K 3800, Japan** CFDA YY-0569, China ISO , Class 3, Worldwide JIS B9920, Class 3, Japan JIS BS5295, Class 3, Japan US Fed Std 209E, Class 1 USAEN-1822 (H14), Europe , USA IEST-RP-CC007, USA , USAUL-C-61010A-1, USA , , Canada EN-61010-1, Europe IEC61010-1, Worldwide *The NSF / ANSI 49 certified models are: LA2-4A1-E, LA2-4A2-E, LA2-4A3-E, LA2-5A1-E, LA2-5A2-E, LA2-5A3-E, LA2-6A1-E, LA2-6A2-E, LA2-6A3-E, LB2-4B1-E, LB2-4B2-E, LB2-4B3-E, LB2-5B1-E, LB2-5B2-E, LB2-5B3-E, LB2-6B1-E, LB2-6B2-E and LB2-6B3-E.

3 Note: LA2 cabinets are certified to NSF, EN, JIS, and CFDA. LB2 cabinets are certified to NSF and CFDA.**EN 12469 and JIS K 3800 are applicable in LA2 Model cabinets use ULPA filters (per ) / H14 per EN 1822 instead of H13 HEPA filters used on many BSCs in the market. HEPA filters only offer typical efficiency at micron, while ULPA filters provide typical efficiency for particle sizes of to FilterDynamic Chamber powder coatLABCULTURE Class II TYPE A2 (LA2) and B2 (LB2) Biosafety cabinets , FEATURING ADVANCED MICROPROCESSOR CONTROLLERP ositive pressure Negative pressure Monitors real-time airflow for safetyAlert the user if airflow is insufficientTemperature independentFast responsePressure Switch (LB2 only)Blower plenum and side walls are surrounded by negative pressurePrevent contaminants from escaping outsideSilver-ion impregnated powder coatInhibit microbial growth to improve safetyEnergy Efficient DC ECM MotorPowered by latest generation DC ECM motor, that is more efficient than legacy ECM and VFD motors70% Energy savings compared to AC motorStable airflow, despite building voltage fluctuations & filter loadingNight Setback mode to further reduce power consumption by 60%10x Filtration efficiency of HEPA filterCreates ISO Class 3 work zone instead of industry-standard ISO Class 534LA2 & LR2 Class II Type A2 / LB2 Class II Type B2 Biological Safety CabinetsLabculture l Labculture NSF 49UL 61010,Large radius for easy cleaningSide-mounted electrical outlets and staggered service fixtures.

4 For easy reachRecessed to contain spillageCurved grill to prevent blockageBlower plenum and side walls are surrounded by negative pressurePrevent contaminants from escaping outside Helps prevent grille blockingComfortable working posturePositive pressure Negative pressure Single Piece WallSingle Piece Work TrayDynamic ChamberRaised Arm RestAngled Drain PanAvailable in , , , and meter models(3', 4', 5', 6' and 8'). Shown with optional telescoping stand. Easy to clean Does not harbor contaminantsRocker Switchesand Pressure Gauge Easy to use switchesDisplays filter loading statusManually adjustable UV timerLABCULTURE Class II TYPE A2 (LA2) and B2 (LB2) Biosafety cabinets , FEATURING ADVANCED MICROPROCESSOR CONTROLLER45 CertificationStandards ComplianceBiosafety CabinetsAir QualityFiltrationElectrical SafetyNSF / ANSI 49 NSF ISO , Class 3, Worldwide JIS B9920, Class 3, Japan JIS BS5295, Class 3, Japan US Fed Std 209E, Class 1 USAEN-1822 (H14), Europe , USA IEST-RP-CC007, USA , USAUL-C-61010A-1, USA , , Canada EN-61010-1, Europe IEC61010-1, Worldwide 10x Filtration efficiency of HEPA filterCreates ISO Class 3 work zone instead of industry-standard ISO Class 5*The NSF / ANSI 49 certified models are.

5 LR2-4S1-E, LR2-4S2-E, LR2-4S3-E, LR2-5S1-E, LR2-5S2-E, LR2-5S3-E, LR2-6S1-E, LR2-6S2-E, and adjustable to desired minutes or hoursProlongs UV lamp, for not turning it ON overnightAdjustable UV TimerULPA FilterPowered by latest generation DC ECM motor, that is more efficient than legacy ECM and VFD motors70% Energy savings compared to AC motorStable airflow, despite building voltage fluctuations & filter loadingNight Setback mode to further reduce power consumption by 60%Energy Efficient DC ECM MotorEsco cabinets use ULPA filters (per ) / H14 per EN 1822 instead of H13 HEPA filters used on many BSCs in the market. HEPA filters only offer typical efficiency at micron, while ULPA filters provide typical efficiency for particle sizes of to micron. powder coatSilver-ion impregnated powder coatInhibit microbial growth to improve safetyRocker Switchesand Pressure Gauge LABCULTURE Class II TYPE A2 (LA2) and B2 (LB2) Biosafety cabinets , FEATURING ADVANCED MICROPROCESSOR CONTROLLER56LA2 & LR2 Class II Type A2 / LB2 Class II Type B2 Biological Safety CabinetsLabculture l Labculture LA2 and LR2 Class II TYPE A2 Biosafety CABINETS6 Cabinet Filtration System Side capture zones Dynamic air barrier, where inflow and downflow converge ULPA-filtered air Unfiltered / potentially contaminated air Room air / Inflow airModel LA2 and LR2 Biological Safety Cabinet Engineering DrawingOptional Exhaust Collar Positions for Thimble-Ducting for LA2 and LR2 ModelsFor BiohazardTop View - All SizesSide View - All Sizes Ambient air is pulled through front grille to create inflow, without going into the work surface.

6 Inflow is joined by half of the downflow, to create front air curtain that is fine-tuned to create a large performance envelope. The combined air stream travels through the back air column towards the blower. Approximately of the air in the common plenum is exhausted through the ULPA filter to the room. The remaining of the air is passed through the downflow ULPA filter and into the work area as a vertical laminar flow air to create ISO Class 3 work surface and prevents cross contamination. Near the work surface, the downflow splits. About half goes to the front grille, and half goes to the rear grille. A small portion enters the the side capture zones to prevent dead air corners (small blue arrows). The design was optimized to give large performance envelope, that provides operator and product protection at wide Inflow and Downflow variation from the Nominal Performance Envelope m/s504060708090100 fpm0 Downflow Velocity Nominal AirflowPersonnel / Product ProtectionInflow fpmArea of Personnel /Product ProtectionNo Personnel /Product ProtectionArea of no Personnel /Product , m/s(70, 105 fpm)1A.

7 (LA2 and LB2) SentinelTM Gold Microprocessor Controller1B. (LR2) Simple Switches Controller 2. Tempered Glass Sash Window 3. Stainless Steel Back Wall 4. Side Panel 5. RS232 Port, Zero Volt Relay Contact 6. Electrical Panel 7. Fluorescent Lamp 8. Service Fixture Retrofit Kit Provision (2 on each side) 9. Electrical Outlet Retrofit Kit Provision10. Stainless Steel Single Piece Work Tray11. Arm Rest12. Drain Valve13. Airflow Sensor14. Exhaust H14 Filter15. Energy-efficient DC ECM Blower16. Downflow H14 Filter17. UV Light Retofit Kit Provision18. IV Bar Retrofit Kit Provision 250 mm ( ")128 mm ( ") 133 mm ( ") 137 mm ( ") 138 mm ( ")140 mm ( ")3'4'5'6'8'370 mm ( ") for LA2-3A/LR2-3S530 mm ( ") for LA2-4A /LR2-4S610 mm ( ") for LA2-5A/LR2-5S711 mm ( ") for LA2-6A/LR2-6S1300 mm ( ") for LA2-8A/LR2-8S288 mm ( ")12815 mm ( ")852 mm ( ")170 mm ( ")623 mm ( ")867710119508 mm (20")MAX. OPENING511671518917670 mm ( ")61413175 mm( ")970 / 1270 / 1570 / 1870 / 2440 mm( "/ "/ "/ "/ ")1115 / 1420 / 1725 / 2030 / 2600 mm( "/ "/ "/ " ")3421540 mm ( ")1 ALA2970 / 1270 / 1570 / 1870 / 2440 mm( "/ "/ "/ "/ ")1115 / 1420 / 1725 / 2030 / 2600 mm( "/ "/ "/ " ")3421540 mm ( ")175 mm( ") BYACCAPPROVED BYCHECKED BYDESIGNED BYDRAWING NUMBERREVISIONSCALE :1:50 DIMENSION : MMTHIRD ANGLE VIEWDESCRIPTION :PRODUCT :MATERIAL :THICKNESS :LR2-4S-EHeadquarters: Esco Micro Pte Ltd21 Changi South Street 1 Singapore 486777 Tel: +65 65420833 Fax: +65 65426920 Web: "THESE DRAWINGS AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF ESCO, ISSUED IN STRICT CONFIDENCE AND SHALL NOT, WITHOUT PRIOR WRITTEN PERMISSION OF ESCO, BE REPRODUCED"NOTE: MMPAGEDRAWN BYUNLESS OTHERWISE SPECIFIEDGENERAL TOLERANCE : MMANGLE TOLERANCE : 1 COLOR: QTY.

8 1 / 17LB2 Class II TYPE B2 Biosafety CABINET7 Ambient air is pulled through the front grille to prevent contamination of the work surface and work product. The inflow does not mix with the clean air within the cabinet work zone. Ambient air is taken in through a pre-filter at the top of the cabinet, and passes through the downflow ULPA filter, entering the work zone as laminar flow. The uniform, non-turbulent air stream protects against cross contamination within and throughout the work area. Near the work surface, the downflow air stream splits with a portion moving toward the front air grille, and the remainder moving to the rear air grille. A small portion of the ULPA filtered downflow enters the intake perforations at the side capture zones at a higher velocity (small blue arrows). A combination of inflow and downflow air streams forms an air barrier that prevents contaminated room air from entering the work zone, and prevents work surface emissions from escaping the work zone.

9 The downflow combined with the inflow air enters the common air plenum. All air in the common plenum is HEPA-filtered and exhausted via a dedicated ducting system to the external environment. ULPA-filtered air Unfiltered / potentially contaminated air Room air / Inflow airCabinet Filtration System Side capture zones Dynamic air barrier, inflow and forward-directed downflow air convergeModel LB2 Biological Safety Cabinet Engineering DrawingFor Biohazard and Chemical Hazard 1. SentinelTM Gold Microprocessor Controller 2. Tempered Glass Sash Window 3. Stainless Steel Back Wall 4. Side Panel 5. Pressure Switch Port 6. Exhaust Sensor 7. Electrical Panel 8. Fluorescent Lamp 9. IV Bar Retrofit Kit Provision10. Service Fixture Retrofit Kit Provision11. Electrical Outlet12. Arm Rest13. Drain Valve14. Exhaust Ducting15. Exhaust H14 Filter16. Energy-efficient DC ECM Blower17. Downflow H14 Filter18. Downflow Sensor19.

10 UV Light Retrofit Kit Provision20. Single Piece Stainless Steel Work Tray21. RS232 Port22. Pre-filter23. Cabinet Power Inlet24. Zero Voltage Relay Contact for Exhaust System25. Zero Voltage Relay Contact for Remote AlarmRecommended LB2 Cabinet Installation Anti BlowbackValve (Optional)Pitot Tube Duct traverse penetration (drill penetrations in ductwork)Exhaust Blower at terminal end (preferably one blower per individual cabinet and connected to emergency power)Air Tight Damper (Required)Downflow AirInflow AirEnables static pressure to be adjusted as filter loads to maintain airflow volumeEnables the cabinet to be sealed off during decontaminationSupply Air (make up for Inflow and Downflow Air), Located far away from exhaust blowerNote: Cabinet shown with optional Support Stand, Air-tight Damper, optional Anti Blowback Valve and optional Exhaust ductwork is not provided by mm (20")Max Opening623 mm ( ")815 mm ( ")852 mm ( ")715 mm ( ")315 mm ( ")1213971415161718192010115681540 mm ( ")970 / 1270 / 1570 / 1870 / 2440 mm( "/ "/ "/ "/ ")1115 / 1420 / 1725 / 2030 / 2600 mm( "/ "/ "/ "/ ")1610 mm ( ")1234180 mm( ")70 mm ( ")250 mm ( ")2524232221300 mm ( ") for LB2-3405 mm ( ") for LB2-4643 mm ( ") for LB2-5820 mm ( ") for LB2-61300 mm ( ")