Blower Coil Air Handler Models BCHD and BCVD

Blower Coil Air HandlerModels BCHD and BCVDAir Terminal Device400-3000 CFMS eptember 2013 BCX-PRC001A-ENCatalog2 BCX-PRC001A-ENIntroductionTrane Blower Coils Factory Packaged How You Need It When You Need ItTrademarksFrostat, Integrated Comfort, Rover, Sigma-Flo, TOPSS, Tracer, Tracer Summit, Trane, and the Trane logo are trademarks or registered trademarks of Trane in the United States and other countries. All trademarks referenced in this document are the trademarks of their respective is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE); LonTalk is a registered trademark of Echelon CorporationUnit sizes 12, 18, 24, 36, 54, 72, 90 MBhKnockouts in all four corners for hanger rodsMain coil with copper tubes and enhances aluminum fins in 2-, 4-, or 6-row hydronic or 4- and 6-row DXThrowaway MERV 8 or MERV 13 filtersInternal filter frame accommodates 1-inchor 2-inch filtersMain and auxiliary drain connections on same side of unit1/2 or 1 HP ECM motor (standard)Direct-drive up to inches total staticeliminates the difficultieswith beltsControl box: options include the UC400 controllerfor single zone VAV; CSTI, ZN010, ZN510 or ZN520 Table of ContentsBCX-PRC001A-EN3 Introduction.

J = 1300 rpm K = 1400 rpm L = 1500 rpm M = 1600 rpm N = 1700 rpm P = 1800 rpm R = 1900 rpm T = 2000 rpm U = 2100 rpm V = 2200 rpm W = 2300 rpm Z = TOPSS base performance Digit 18 — Electric Heat Stages 1 = 1-stage 2 = 2-stage 0 = none Digits 19, 20, 21 — Electric Heat Digit 22 — Electric Heat Controls 0 = None A = 24 volt magnetic contactors

Tags:

  1500, 3100

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Blower Coil Air Handler Models BCHD and BCVD

1 Blower Coil Air HandlerModels BCHD and BCVDAir Terminal Device400-3000 CFMS eptember 2013 BCX-PRC001A-ENCatalog2 BCX-PRC001A-ENIntroductionTrane Blower Coils Factory Packaged How You Need It When You Need ItTrademarksFrostat, Integrated Comfort, Rover, Sigma-Flo, TOPSS, Tracer, Tracer Summit, Trane, and the Trane logo are trademarks or registered trademarks of Trane in the United States and other countries. All trademarks referenced in this document are the trademarks of their respective is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE); LonTalk is a registered trademark of Echelon CorporationUnit sizes 12, 18, 24, 36, 54, 72, 90 MBhKnockouts in all four corners for hanger rodsMain coil with copper tubes and enhances aluminum fins in 2-, 4-, or 6-row hydronic or 4- and 6-row DXThrowaway MERV 8 or MERV 13 filtersInternal filter frame accommodates 1-inchor 2-inch filtersMain and auxiliary drain connections on same side of unit1/2 or 1 HP ECM motor (standard)Direct-drive up to inches total staticeliminates the difficultieswith beltsControl box: options include the UC400 controllerfor single zone VAV; CSTI, ZN010, ZN510 or ZN520 Table of ContentsBCX-PRC001A-EN3 Introduction.

2 2 Model Number Description .. 6 Features and Benefits .. 8 Factory Packaged What You Need When You Need It .. 8 Single Source Responsibility .. 8 Piping Packages .. 9 Energy Efficiency .. 9 Controls .. 9 CSTI .. 9 Tracer Controllers .. 9 End Devices .. 9 Flexibility .. 9 Coil Options .. 10 Filter Placement Options .. 10 Motor Options .. 10 Indoor Air Quality .. 10 Drain Pans .. 11 Filtration .. 11 Ventilation .. 11 Dehumidification .. 11 Easy to Service .. 11 Durability .. 11 Optional Accessory Sections .. 12 Mixing Box .. 12 Angle Filter Box and Combination Angle Filter/Mixing Box .. 12 Electric Heat .. 12 Steam Coils .. 12 Application Considerations .. 13 Two-Pipe Units .. 13 Two-Pipe Units With Electric Heat .. 13 Changeover in Two-Pipe Systems .. 14 Four-Pipe Units .. 14DX Cooling Units .. 14 Dehumidification .. 14 Four-Pipe Unit with Reheat .. 15 Chilled-Water Reset .. 15 Airside Economizer .. 15 Location and Installation.

3 15 Acoustics .. 16 Operating Limitations .. 164 BCX-PRC001A-ENTypical Blower Coil Applications .. 17 Selection Procedure .. 20 Cooling Selection Example .. 21 Heating Selection Example .. 22 General Data .. 23 Valve Package Waterflow Limits .. 25 Coil Circuiting .. 25 Performance Data .. 26 Air pressure drop adjustments .. 26 Water Pressure Drop .. 28 Fan Curves .. 35 Chilled Water Cooling Capacities .. 55 High-Capacity Chilled Water Cooling Capacities .. 56 Distributor Selection .. 60R-410A, DX Cooling Capacities .. 61 Hot Water Heating Capacities .. 67 Controls .. 69 VelociTach ECM Engine Controller .. 70 Control Options .. 71 Manual Fan Speed Switch (FSS) .. 71 Customer Supplied Thermostat Interface (CSTI) .. 72 Tracer Controls and Controllers .. 72 Tracer ZN010 Controller .. 73 Tracer ZN510 Controller .. 73 Tracer ZN520 Controller .. 73 Tracer UC400 Controller .. 77 Tracer Controls Sequence of Operation .. 79 End Device Options.

4 80 Zone Sensor Options .. 81 Control Valves .. 83 Two-Position Control Valves .. 83 Modulating Control Valves (Tracer ZN520 or UC400 only) .. 83 How to Choose the Correct Control Valve .. 84 Electrical Data .. 87 Dimensions and Weights .. 90 Horizontal Blower Coil .. 90 Vertical Blower Coil .. 91 Angle Filter and Mixing Box .. 92 Bottom or Top Access Filter Box .. 93 BCX-PRC001A-EN5 Electric Heat .. 94 Steam Coil .. 96 Coil Connections .. 97 Piping Packages .. 97 Basic Piping .. 98 Deluxe Piping .. 99 Mechanical Specifications .. 101 General .. 101 Casings .. 101 Coils .. 101 Fan .. 102EC Motors .. 102 Drain Pan .. 102 Filters .. 102 Mixing Box .. 103 Piping Packages .. 103 Electric Heater .. 103 Controls .. 1036 BCX-PRC001A-ENFollowing is a complete description of the Blower coil model number. Each digit in the model number has a corresponding code that identifies specific unit 1, 2, 3, 4 Unit ModelBCHD = Horizontal Blower CoilBCVD = Vertical Blower CoilDigits 5, 6, 7 Unit Size012 = Unit size 12 - 1 ton018 = Unit size 18 - 1 1/2 ton024 = Unit size 24 - 2 ton036 = Unit size 36 - 3 ton054 = Unit size 54 - 4 1/2 ton072 = Unit size 72 - 6 ton090 = Unit size 90 - 7 1/2 tonDigit 8 Unit Voltage A = 115/60/1B = 208/60/1C = 230/60/1D = 277/60/1J = 220/50/1K = 240/50/1 Digit 9 Insulation Type1 = 1 inch Matte-faced insulation2 = 1 inch Foil-faced insulationDigits 10, 11 Design Sequence ** = Factory sets the design sequenceDigit 12 Motor and Control Box LocationA = Same side as coil connections,horizontal or counterswirl optionsonlyB = Opposite side from coil connections,horizontal or counterswirl optionsonlyC = Same side as coil connections,preswirl option onlyD = Opposite side from coil connections.

5 Preswirl onlyDigit 13 Coil Connection Side 1 = PVC drain pan right-hand coil anddrain connections2 = PVC drain pan left-hand coil anddrain connections3 = Stainless steel drain pan right-hand coil and drain connections4 = Stainless steel drain pan left-hand coil and drain connections0 = NoneDigit 14 Coil #1 First in AirstreamNote:All coils are hydronic unless stated = No coil 1A = 1-row preheatF = 4-rowG = 6-rowJ = 4-row with autochangeoverK = 6-row with autochangeoverL = 2-row high capacity preheatM = 4-row high capacityN = 6-row high capacityR = 4-row high capacity withautochangeoverT = 6-row high capacity withautochangeover1 = 3-row DX coil 3/16-inch ( ) dist 2 = 4-row DX coil 3/16-inch ( ) dist3 = 6-row DX coil 3/16-inch ( ) dist4 = 3-row DX coil 3/16-inch ( ) dist5 = 4-row DX coil 3/16-inch ( ) dist 6 = 6-row DX coil 3/16-inch ( ) dist 7 = 4-row DX coil 3/16-inch ( ) dist,heat pump8 = 6-row DX coil, 3/16-inch ( ) dist,heat pumpDigit 15 Unit Coil #2 Note:All coils are hydronic unless stated = No coil 2A = 1-row reheatF = 4-rowG = 6-rowJ = 4-row with autochangeoverK = 6-row with autochangeoverL = 2-row high capacity reheatM = 4-row high capacityN = 6-row high capacityR = 4-row high capacity withautochangeoverT = 6-row high capacity withautochangeover1 = 3-row DX coil 3/16-inch ( ) dist 2 = 4-row DX coil 3/16-inch ( ) dist3 = 6-row DX coil 3/16-inch ( ) dist4 = 3-row DX coil 3/16-inch ( ) dist5 = 4-row DX coil 3/16-inch ( ) dist 6 = 6-row DX coil 3/16-inch ( ) dist 7 = 4-row DX coil 3/16-inch ( ) dist,heat pump8 = 6-row DX coil, 3/16-inch ( )

6 Dist,heat pumpDigit 16 Motor Horsepower2 = 1/2 hp4 = 1 hpDigit 17 RPMA = 500 rpmB = 600 rpm C = 700 rpmD = 800 rpmE = 900 rpmF = 1000 rpmG = 1100 rpmH = 1200 rpmJ = 1300 rpmK = 1400 rpmL = 1500 rpmM = 1600 rpmN = 1700 rpmP = 1800 rpmR = 1900 rpmT = 2000 rpmU = 2100 rpmV = 2200 rpmW = 2300 rpmZ = TOPSS base performanceDigit 18 Electric Heat Stages1 = 1-stage2 = 2-stage0 = noneDigits 19, 20, 21 Electric Heat Digit 22 Electric Heat Controls0 = NoneA = 24 volt magnetic contactorsB = 24 volt mercury contactorsDigit 23 Electric Heat Options0 = NoneA = Line fuseB = Door interlocking disconnect switchC = A and BDigit 24 Filters0 = NoneA = 1-in. throwawayB = 2-in. MERV 8 throwawayC = 2-in. MERV 13 throwaway010 = kW015 = kW060 = kW020 = kW065 = kW025 = kW070 = kW030 = kW075 = kW035 = kW080 = kW040 = kW090 = kW045 = kW100 = kW050 = kW110 = kW055 = kW000 = NoneModel Number DescriptionBCX-PRC001A-EN7 Model Number DescriptionDigit 25 Accessory Section0 = NoneA = Mixing box onlyB = Angle filter boxC = Angle filter/mixing boxD = Top access filter moduleE = Bottom access filter moduleF = A and DG = A and EH = Steam coil moduleJ = A and HK = B and HL = C and HM = D and HN = E and HP = A, D and HR = A, E and HDigit 26 Control Type1 = CSTI2 = Tracer ZN0103 = Tracer ZN5104 = Tracer ZN5205 = UC4006 = No controls (FSS)

7 Digit 27 Coil #1 Control Valve Type0 = NoneA = 2-way, 2-position, = 2-way, 2-position, = 3-way, 2-position, = 3-way, 2-position, = 2-way modulatingF = 3-way, modulatingG = Field-supplied valve, 2-position, = Field-supplied valve, 2-position, = Field-supplied modulating valveK = Field-supplied analog valveDigit 28 Coil #1 Control Valve Cv0 = NoneA = Cv, 1/2-in. valve and pipeB = Cv, 1/2-in. valve, 3/4-in. pipeC = Cv, 1/2-in. valve, 3/4-in. pipeD = Cv, 1-in. valve and pipeE = Cv, 1-in. valve and pipeF = Cv, 1 1/4-in. valve and pipeG = Cv, 1/2-in. valve and pipeH = Cv, 1/2-in. valve and pipeK = Cv, 1-in. valve and pipeQ = Cv, 1/2-in. valve, 3/4-in. pipeR = Cv, 1/2-in. valve, 3/4-inc. pipeT = Cv, 1/2-in. valve, 3/4-in. pipeU = Cv, 1/2-in. valve, 3/4-in. pipeDigit 29 Coil #1 Piping Package0 = None1 = Basic piping package2 = Deluxe piping packageDigit 30 Coil #2 Control Valve 0 = NoneA = 2-way, 2-position, = 2-way, 2-position, = 3-way, 2-position, = 3-way, 2-position, = 2-way modulatingF = 3-way modulatingG = Field-supplied valve, 2-position = Field-supplied valve, 2-position = Field-supplied modulating valveK = Field-supplied analog valveDigit 31 Coil #2 Control Valve Cv0 = NoneA = Cv, 1/2-in.

8 Valve and pipeB = Cv, 1/2-in. valve, 3/4-in. pipeC = Cv, 1/2-in. valve, 3/4-in. pipeD = Cv, 1-in. valve and pipeE = Cv, 1-in. valve and pipeF = Cv, 1 1/4-in. valve and pipeG = Cv, 1/2-in. valve and pipeH = Cv, 1/2-in. valve and pipeK = Cv, 1-in. valve and pipeQ = Cv, 1/2-in. valve, 3/4-in. pipeR = Cv, 1/2-in. valve, 3/4-in. pipeT = Cv, 1/2-in. valve, 3/4-in. pipeU = Cv, 1/2-in. valve, 3/4-in. pipeDigit 32 Coil #2 Piping Package0 = None1 = Basic piping package2 = Deluxe piping packageDigit 33 Remote Heat Options0 = No remote heat1 = Remote staged electric heat2 = Remote 2-position hot water, 34 Mixing Box Damper ActuatorNote:The back damper is the control damper when actuators are ordered. The back damper is or as = None1 = 2-position, , ship loose2 = Modulating, = Modulating, = Modulating, ship loose5 = Field-supplied 2-position, = Field-supplied 2-position, = Field-supplied modulatingDigit 35 Factory Mounted Control Options0 = NoneC = Condensate overflowD = Low LimitK = Condensate overflow and low limitDigit 36 Control Options 20 = NoneA = Outside air sensor, field-mountedB = Discharge air sensorC = Outside air and discharge air sensorDigit 37 Control Options 30 = NoneA = Dehumidification with communicatedvalueB = Dehumidification with local humiditysensorDigit 38 Zone Sensors0 = None1 = Wall-mounted temp sensor (SP, OA, OCC/UNCOCC, COMM)3 = Wall-mounted temp sensor(SP, OCC/UNOCC, COMM)4 = Wall-mounted temp sensor(OCC/UNOCC, COMMC = Wireless temp sensor, unit-mounted receiverE = Wall-mounted temp sensor (SP, OALMH, OCC/UNOCC, COMM)F = Wall-mounted display sensor (SP, OALMH, COMM))

9 G = Wireless display sensor, unit-mounted receiver (SP, OALMH)H = Wall-mounted FSSD igit 39 Seismic Certification0 = NoneDigit 40 Extra Filter0 = None1 = Ship loose extra 1-in. Throwaway2 = Ship loose extra 2-in. MERV 8 throwaway3 = Ship loose extra 2-in. MERV 13 throwaway8 BCX-PRC001A-ENFeatures and BenefitsFactory Packaged What You Need When You Need ItThe Trane Blower coil air Handler , model BCHD/BCVD, accommodates a variety of applications while providing a low-cost method of air conditioning and/or heating buildings. These compact, low-profile units can fit in small spaces and are floor or ceiling mounted. With a minimum of effort, they can be relocated within the building as needs units are light-duty air handlers, ranging from to tons nominal capacity. They are typically used in schools, hospitals, offices, stores, and similar applications. BCHD/BCVD units are UL listed to and Canadian safety standards for all 115, 208, 230, and 277 volt 60 hertz motors and 220 and 240 volt 50 hertz Source ResponsibilityTrane is the single source of responsibility because we ship BCHD/BCVD units from the factory as a total package.

10 Included in the package are factory-mounted coils, filters, controls, direct-drive motors, and duct collars. Also, factory-provided piping packages are an available option. Because we provide the total package, this helps reduce job site labor and installation 1. Horizontal Blower coilBCX-PRC001A-EN9 Features and BenefitsPiping PackagesAll Blower coil air handlers are available with factory-built piping package options for field installation using field-supplied interconnecting piping. Basic or deluxe piping package options are available with a variety of control valve options: Two- or three-way 1/2-inch, 1-inch, or 1-1/4-inch Two-position or modulatingThe basic piping package consists of two shutoff ball valves. The deluxe piping package has one shutoff ball valve, a strainer, and a circuit setter balancing valve. Basic or deluxe piping packages with a three-way control valve also include a balancing fitting on the bypass line. Energy Efficiency Trane s commitment to providing premium quality products has led to the exclusive use of Electronically Commutated Motors (ECM) in all Blower coil (BCHD/BCVD) Models .